These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 19758833)

  • 1. Comparative analysis of methods for automatic detection and quantification of microvolt T-wave alternans.
    Burattini L; Bini S; Burattini R
    Med Eng Phys; 2009 Dec; 31(10):1290-8. PubMed ID: 19758833
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automatic microvolt T-wave alternans identification in relation to ECG interferences surviving preprocessing.
    Burattini L; Bini S; Burattini R
    Med Eng Phys; 2011 Jan; 33(1):17-30. PubMed ID: 20920875
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Correlation method versus enhanced modified moving average method for automatic detection of T-wave alternans.
    Burattini L; Bini S; Burattini R
    Comput Methods Programs Biomed; 2010 Apr; 98(1):94-102. PubMed ID: 20188430
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the T-wave alternans detection methods: a simulation study.
    Janusek D; Pawlowski Z; Maniewski R
    Anadolu Kardiyol Derg; 2007 Jul; 7 Suppl 1():116-9. PubMed ID: 17584701
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of noise on T-wave alternans measurement in ambulatory ECGs using modified moving average versus spectral method.
    Selvaraj RJ; Chauhan VS
    Pacing Clin Electrophysiol; 2009 May; 32(5):632-41. PubMed ID: 19422585
    [TBL] [Abstract][Full Text] [Related]  

  • 6. T wave alternans evaluation using adaptive time-frequency signal analysis and non-negative matrix factorization.
    Ghoraani B; Krishnan S; Selvaraj RJ; Chauhan VS
    Med Eng Phys; 2011 Jul; 33(6):700-11. PubMed ID: 21333581
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multilead analysis of T-wave alternans in the ECG using principal component analysis.
    Monasterio V; Laguna P; Martínez JP
    IEEE Trans Biomed Eng; 2009 Jul; 56(7):1880-90. PubMed ID: 19272977
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Predicting arrhythmia-free survival using spectral and modified-moving average analyses of T-wave alternans.
    Cox V; Patel M; Kim J; Liu T; Sivaraman G; Narayan SM
    Pacing Clin Electrophysiol; 2007 Mar; 30(3):352-8. PubMed ID: 17367354
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microvolt T-wave alternans: a review of techniques, interpretation, utility, clinical studies, and future perspectives.
    Haghjoo M; Arya A; Sadr-Ameli MA
    Int J Cardiol; 2006 May; 109(3):293-306. PubMed ID: 16054250
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [An algorithm for detecting T-wave alternans (TWA) based on the maximum of T-waves].
    Zhao J; Hua M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Oct; 22(5):951-5. PubMed ID: 16294729
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Methodological principles of T wave alternans analysis: a unified framework.
    Martínez JP; Olmos S
    IEEE Trans Biomed Eng; 2005 Apr; 52(4):599-613. PubMed ID: 15825862
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Enhanced detection of arrhythmia vulnerability using T wave alternans, left ventricular ejection fraction, and programmed ventricular stimulation: a prospective study in subjects with chronic ischemic heart disease.
    Rashba EJ; Osman AF; Macmurdy K; Kirk MM; Sarang SE; Peters RW; Shorofsky SR; Gold MR
    J Cardiovasc Electrophysiol; 2004 Feb; 15(2):170-6. PubMed ID: 15028046
    [TBL] [Abstract][Full Text] [Related]  

  • 13. T-wave alternans found in preventricular tachyarrhythmias in CCU patients using a wavelet transform-based methodology.
    Romero I; Grubb NR; Clegg GR; Robertson CE; Addison PS; Watson JN
    IEEE Trans Biomed Eng; 2008 Nov; 55(11):2658-65. PubMed ID: 18990637
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A time-domain hybrid analysis method for detecting and quantifying T-wave alternans.
    Wan X; Yan K; Zhang L; Zeng Y
    Comput Math Methods Med; 2014; 2014():502981. PubMed ID: 24803951
    [TBL] [Abstract][Full Text] [Related]  

  • 15. T-wave alternans in apparently healthy subjects and in different subsets of patients with ischaemic heart disease.
    Mollo R; Cosenza A; Spinelli A; Coviello I; Careri G; Battipaglia I; Laurito M; Pinnacchio G; Lanza GA; Crea F
    Europace; 2012 Feb; 14(2):272-7. PubMed ID: 21908448
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Adaptive match filter based method for time vs. amplitude characterization of microvolt ECG T-wave alternans.
    Burattini L; Zareba W; Burattini R
    Ann Biomed Eng; 2008 Sep; 36(9):1558-64. PubMed ID: 18618261
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of acute mental stress and exercise on T-wave alternans in patients with implantable cardioverter defibrillators and controls.
    Kop WJ; Krantz DS; Nearing BD; Gottdiener JS; Quigley JF; O'Callahan M; DelNegro AA; Friehling TD; Karasik P; Suchday S; Levine J; Verrier RL
    Circulation; 2004 Apr; 109(15):1864-9. PubMed ID: 15037524
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of heart rate variability during alterations in stress: complex demodulation vs. spectral analysis.
    Wilhelm FH; Grossman P; Roth WT
    Biomed Sci Instrum; 2005; 41():346-51. PubMed ID: 15850130
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of T-wave alternans using the dominant T-wave paradigm.
    Mainardi L; Sassi R
    J Electrocardiol; 2011; 44(2):119-25. PubMed ID: 21353060
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of T-wave alternans after acute myocardial infarction: influence of the timing of PTCA on cardiac electrical stabilization.
    Pelicano N; Oliveira M; da Silva N; Anão A; Feliciano J; Fiarresga A; Alves S; Silva S; Quininha J
    Rev Port Cardiol; 2006 Apr; 25(4):379-87. PubMed ID: 16869203
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.