859 related articles for article (PubMed ID: 19762743)
1. An analysis of drug delivery dynamics via a pediatric central venous infusion system: quantification of delays in achieving intended doses.
Bartels K; Moss DR; Peterfreund RA
Anesth Analg; 2009 Oct; 109(4):1156-61. PubMed ID: 19762743
[TBL] [Abstract][Full Text] [Related]
2. An in vitro analysis of central venous drug delivery by continuous infusion: the effect of manifold design and port selection.
Moss DR; Bartels K; Peterfreund GL; Lovich MA; Sims NM; Peterfreund RA
Anesth Analg; 2009 Nov; 109(5):1524-9. PubMed ID: 19843791
[TBL] [Abstract][Full Text] [Related]
3. Impact of syringe size on the performance of infusion pumps at low flow rates.
Schmidt N; Saez C; Seri I; Maturana A
Pediatr Crit Care Med; 2010 Mar; 11(2):282-6. PubMed ID: 19935442
[TBL] [Abstract][Full Text] [Related]
4. Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps.
Neff SB; Neff TA; Gerber S; Weiss MM
Eur J Anaesthesiol; 2007 Jul; 24(7):602-8. PubMed ID: 17261217
[TBL] [Abstract][Full Text] [Related]
5. Central venous catheter infusions: a laboratory model shows large differences in drug delivery dynamics related to catheter dead volume.
Lovich MA; Peterfreund GL; Sims NM; Peterfreund RA
Crit Care Med; 2007 Dec; 35(12):2792-8. PubMed ID: 18074479
[TBL] [Abstract][Full Text] [Related]
6. The impact on drug mass flow rate of interrupting and resuming carrier fluid flow: an in vitro study on a very low dead-space volume infusion set.
Lannoy D; Decaudin B; Simon N; Barthelemy C; Debaene B; Odou P
Anesth Analg; 2012 Feb; 114(2):328-32. PubMed ID: 22025488
[TBL] [Abstract][Full Text] [Related]
7. Accurate continuous drug delivery at low infusion rate with a novel microvolumetric infusion pump (MVIP): pump design, evaluation and comparison to the current standard.
Weiss M; Gerber S; Füchslin RM; Neff TA
Anaesthesia; 2004 Nov; 59(11):1133-7. PubMed ID: 15479325
[TBL] [Abstract][Full Text] [Related]
8. The delivery of drugs to patients by continuous intravenous infusion: modeling predicts potential dose fluctuations depending on flow rates and infusion system dead volume.
Lovich MA; Kinnealley ME; Sims NM; Peterfreund RA
Anesth Analg; 2006 Apr; 102(4):1147-53. PubMed ID: 16551914
[TBL] [Abstract][Full Text] [Related]
9. Impact of multiaccess infusion devices on in vitro drug delivery during multi-infusion therapy.
Décaudin B; Dewulf S; Lannoy D; Simon N; Secq A; Barthélémy C; Debaene B; Odou P
Anesth Analg; 2009 Oct; 109(4):1147-55. PubMed ID: 19762742
[TBL] [Abstract][Full Text] [Related]
10. [Factors altering low-flow drug delivery using syringe pumps: Consequences on vasoactive drug infusion in preterm infant].
Rakza T; Richard A; Lelieur AC; Villaume I; Huyghe A; Nempont C; Storme L
Arch Pediatr; 2005 May; 12(5):548-54. PubMed ID: 15885544
[TBL] [Abstract][Full Text] [Related]
11. Connecting multiple low-flow intravenous infusions in the newborn: problems and possible solutions.
Levi DS; Peterson N; Shah SD; Rakholia B; Haught A; Carman G
Pediatr Crit Care Med; 2010 Mar; 11(2):275-81. PubMed ID: 20068501
[TBL] [Abstract][Full Text] [Related]
12. Syringe Pump Performance Maintained with IV Filter Use During Low Flow Rate Delivery for Pediatric Patients.
Chau DF; Vasilopoulos T; Schoepf M; Zhang C; Fahy BG
Anesth Analg; 2016 Sep; 123(3):705-14. PubMed ID: 27074895
[TBL] [Abstract][Full Text] [Related]
13. Novel Pump Control Technology Accelerates Drug Delivery Onset in a Model of Pediatric Drug Infusion.
Parker MJ; Lovich MA; Tsao AC; Deng H; Houle T; Peterfreund RA
Anesth Analg; 2017 Apr; 124(4):1129-1134. PubMed ID: 28181934
[TBL] [Abstract][Full Text] [Related]
14. Delivery interaction between co-infused medications: an in vitro modeling study of microinfusion.
Tsao AC; Lovich MA; Parker MJ; Zheng H; Peterfreund RA
Paediatr Anaesth; 2013 Jan; 23(1):33-9. PubMed ID: 22712626
[TBL] [Abstract][Full Text] [Related]
15. Drug infusion system manifold dead-volume impacts the delivery response time to changes in infused medication doses in vitro and also in vivo in anesthetized swine.
Lovich MA; Wakim MG; Wei A; Parker MJ; Maslov MY; Pezone MJ; Tsukada H; Peterfreund RA
Anesth Analg; 2013 Dec; 117(6):1313-8. PubMed ID: 24257380
[TBL] [Abstract][Full Text] [Related]
16. Medication and volume delivery by gravity-driven micro-drip intravenous infusion: potential variations during "wide-open" flow.
Pierce ET; Kumar V; Zheng H; Peterfreund RA
Anesth Analg; 2013 Mar; 116(3):614-8. PubMed ID: 23400996
[TBL] [Abstract][Full Text] [Related]
17. Computer control of drug delivery by continuous intravenous infusion: bridging the gap between intended and actual drug delivery.
Parker MJ; Lovich MA; Tsao AC; Wei AE; Wakim MG; Maslov MY; Tsukada H; Peterfreund RA
Anesthesiology; 2015 Mar; 122(3):647-58. PubMed ID: 25419684
[TBL] [Abstract][Full Text] [Related]
18. Syringe size and flow rate affect drug delivery from syringe pumps.
Weiss M; Hug MI; Neff T; Fischer J
Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
[TBL] [Abstract][Full Text] [Related]
19. Discrepancies between predicted and observed rates of intravenous gentamicin delivery for neonates.
Sherwin CM; McCaffrey F; Broadbent RS; Reith DM; Medlicott NJ
J Pharm Pharmacol; 2009 Apr; 61(4):465-71. PubMed ID: 19298693
[TBL] [Abstract][Full Text] [Related]
20. The effect of syringe size on reliability and safety of low-flow infusions.
Neal D; Lin JA
Pediatr Crit Care Med; 2009 Sep; 10(5):592-6. PubMed ID: 19451854
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]