These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
7. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants. Goheen KL; Vermilyea SG; Vossoughi J; Agar JR Int J Oral Maxillofac Implants; 1994; 9(2):149-55. PubMed ID: 8206549 [TBL] [Abstract][Full Text] [Related]
8. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 3: Preload and tensile fracture load testing. Al Jabbari YS; Fournelle R; Ziebert G; Toth J; Iacopino AM J Prosthodont; 2008 Apr; 17(3):192-200. PubMed ID: 18205737 [TBL] [Abstract][Full Text] [Related]
9. Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique--a comparative in vivo study. Schmitt J; Holst S; Eitner S; Schlegel A; Wichmann M; Hamel J Int J Prosthodont; 2009; 22(2):193-200. PubMed ID: 19418868 [TBL] [Abstract][Full Text] [Related]
10. Comparison of torque measurements and clinical handling of various surgical motors. Neugebauer J; Scheer M; Mischkowski RA; An SH; Karapetian VE; Toutenburg H; Zoeller JE Int J Oral Maxillofac Implants; 2009; 24(3):469-76. PubMed ID: 19587869 [TBL] [Abstract][Full Text] [Related]
11. Accuracy of a manual torque application device for morse-taper implants: a technical note. Cehreli MC; Akça K; Tönük E Int J Oral Maxillofac Implants; 2004; 19(5):743-8. PubMed ID: 15508992 [TBL] [Abstract][Full Text] [Related]
12. Experimental study on the factors affecting torque of beam-type implant torque wrenches. Shiba H; Sato Y; Furuya J; Osawa T; Isobe A; Hayashi M; Kitagawa N BMC Oral Health; 2021 Jul; 21(1):344. PubMed ID: 34266423 [TBL] [Abstract][Full Text] [Related]
13. Loss of Accuracy of Torque Wrenches Due to Clinical Use and Cleaning Procedure: Short Communication. Stroosnijder E; Gresnigt MM; Meisberger EW; Cune MS Int J Prosthodont; 2016; 29(3):253-5. PubMed ID: 27148984 [TBL] [Abstract][Full Text] [Related]
14. Testing and calibrating the mechanical-type toggle torque wrenches used in implant dentistry: A dental technique. Wadhwani CPK; O'Brien R; Rosen PS; Chung KH J Prosthet Dent; 2020 Mar; 123(3):403-407. PubMed ID: 31383530 [TBL] [Abstract][Full Text] [Related]
15. The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems. Erdem MA; Karatasli B; Dinçer Kose O; Kose TE; Çene E; Aydın Aya S; Cankaya AB Biomed Res Int; 2017; 2017():8652720. PubMed ID: 29238725 [TBL] [Abstract][Full Text] [Related]
16. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. Byrne D; Jacobs S; O'Connell B; Houston F; Claffey N J Prosthodont; 2006; 15(3):164-71. PubMed ID: 16681498 [TBL] [Abstract][Full Text] [Related]
17. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter. Tan BF; Tan KB; Nicholls JI Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980 [TBL] [Abstract][Full Text] [Related]
18. The dynamic natures of implant loading. Wang RF; Kang B; Lang LA; Razzoog ME J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663 [TBL] [Abstract][Full Text] [Related]
19. Comparative analysis of deformation of two implant/abutment connection systems during implant insertion. An in vitro study. Bambini F; Memè L; Pellecchia M; Sabatucci A; Selvaggio R Minerva Stomatol; 2005 Mar; 54(3):129-38. PubMed ID: 15920445 [TBL] [Abstract][Full Text] [Related]
20. Comparison of electronic versus mechanical torque-limiting devices for dental implants: An in vitro study. Faraj MA; Bidra AS; Taylor TD; Kuo CL J Prosthodont; 2023 Aug; ():. PubMed ID: 37586407 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]