These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 19765196)

  • 1. Variability of mechanical torque-limiting devices in clinical service at a US dental school.
    McCracken MS; Mitchell L; Hegde R; Mavalli MD
    J Prosthodont; 2010 Jan; 19(1):20-4. PubMed ID: 19765196
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of the implant torque wrench following time in clinical service.
    Gutierrez J; Nicholls JI; Libman WJ; Butson TJ
    Int J Prosthodont; 1997; 10(6):562-7. PubMed ID: 9495178
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of design and torque measurements of various manual wrenches.
    Neugebauer J; Petermöller S; Scheer M; Happe A; Faber FJ; Zoeller JE
    Int J Oral Maxillofac Implants; 2015; 30(3):526-33. PubMed ID: 26009903
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of activation rate on output torque values from a dental implant toggle-style torque wrench.
    Wadhwani CPK; Frantz WT; Schoenbaum TR; Rosen PS; Nhan D; Chung KH
    J Prosthet Dent; 2023 May; 129(5):763-768. PubMed ID: 34482966
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of mechanical torque-limiting devices for implants.
    Standlee JP; Caputo AA; Chwu MY; Sun TT
    Int J Oral Maxillofac Implants; 2002; 17(2):220-4. PubMed ID: 11958404
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of friction-style and spring-style mechanical torque limiting devices for dental implants.
    Vallee MC; Conrad HJ; Basu S; Seong WJ
    J Prosthet Dent; 2008 Aug; 100(2):86-92. PubMed ID: 18672124
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants.
    Goheen KL; Vermilyea SG; Vossoughi J; Agar JR
    Int J Oral Maxillofac Implants; 1994; 9(2):149-55. PubMed ID: 8206549
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical behavior and failure analysis of prosthetic retaining screws after long-term use in vivo. Part 3: Preload and tensile fracture load testing.
    Al Jabbari YS; Fournelle R; Ziebert G; Toth J; Iacopino AM
    J Prosthodont; 2008 Apr; 17(3):192-200. PubMed ID: 18205737
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique--a comparative in vivo study.
    Schmitt J; Holst S; Eitner S; Schlegel A; Wichmann M; Hamel J
    Int J Prosthodont; 2009; 22(2):193-200. PubMed ID: 19418868
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of torque measurements and clinical handling of various surgical motors.
    Neugebauer J; Scheer M; Mischkowski RA; An SH; Karapetian VE; Toutenburg H; Zoeller JE
    Int J Oral Maxillofac Implants; 2009; 24(3):469-76. PubMed ID: 19587869
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of a manual torque application device for morse-taper implants: a technical note.
    Cehreli MC; Akça K; Tönük E
    Int J Oral Maxillofac Implants; 2004; 19(5):743-8. PubMed ID: 15508992
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental study on the factors affecting torque of beam-type implant torque wrenches.
    Shiba H; Sato Y; Furuya J; Osawa T; Isobe A; Hayashi M; Kitagawa N
    BMC Oral Health; 2021 Jul; 21(1):344. PubMed ID: 34266423
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Loss of Accuracy of Torque Wrenches Due to Clinical Use and Cleaning Procedure: Short Communication.
    Stroosnijder E; Gresnigt MM; Meisberger EW; Cune MS
    Int J Prosthodont; 2016; 29(3):253-5. PubMed ID: 27148984
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Testing and calibrating the mechanical-type toggle torque wrenches used in implant dentistry: A dental technique.
    Wadhwani CPK; O'Brien R; Rosen PS; Chung KH
    J Prosthet Dent; 2020 Mar; 123(3):403-407. PubMed ID: 31383530
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems.
    Erdem MA; Karatasli B; Dinçer Kose O; Kose TE; Çene E; Aydın Aya S; Cankaya AB
    Biomed Res Int; 2017; 2017():8652720. PubMed ID: 29238725
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies.
    Byrne D; Jacobs S; O'Connell B; Houston F; Claffey N
    J Prosthodont; 2006; 15(3):164-71. PubMed ID: 16681498
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
    Tan BF; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The dynamic natures of implant loading.
    Wang RF; Kang B; Lang LA; Razzoog ME
    J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative analysis of deformation of two implant/abutment connection systems during implant insertion. An in vitro study.
    Bambini F; Memè L; Pellecchia M; Sabatucci A; Selvaggio R
    Minerva Stomatol; 2005 Mar; 54(3):129-38. PubMed ID: 15920445
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of electronic versus mechanical torque-limiting devices for dental implants: An in vitro study.
    Faraj MA; Bidra AS; Taylor TD; Kuo CL
    J Prosthodont; 2023 Aug; ():. PubMed ID: 37586407
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.