These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
9. Cerebral intolerance during flow arrested carotid angioplasty. St Louis M; Park BD; Dahn M; Bozeman P Vasc Endovascular Surg; 2012 Jan; 46(1):85-8. PubMed ID: 22156156 [TBL] [Abstract][Full Text] [Related]
10. [Case of internal carotid artery stenosis complicated with filter obstruction during carotid artery stenting with an embolus protection filter]. Hayashi K; Kitagawa N; Morikawa M; Hiu T; Morofuji Y; Suyama K; Nagata I No Shinkei Geka; 2008 Dec; 36(12):1133-8. PubMed ID: 19086445 [TBL] [Abstract][Full Text] [Related]
11. Tandem balloon protection during emergency carotid artery stenting of a stenotic ICA lesion with intraluminal thrombus. Imai K; Makino M; Niwa F; Takegami T; Koike H; Azuma Y; Oshima F; Oda K; Kakita K J Endovasc Ther; 2007 Apr; 14(2):214-8. PubMed ID: 17488180 [TBL] [Abstract][Full Text] [Related]
12. Efficacy of a proximal occlusion catheter with reversal of flow in the prevention of embolic events during carotid artery stenting: an experimental analysis. Ohki T; Parodi J; Veith FJ; Bates M; Bade M; Chang D; Mehta M; Rabin J; Goldstein K; Harvey J; Lipsitz E J Vasc Surg; 2001 Mar; 33(3):504-9. PubMed ID: 11241119 [TBL] [Abstract][Full Text] [Related]
13. Hemodynamic conditions at the carotid bifurcation during protective common carotid occlusion. Ouriel K; Greenberg RK; Sarac TP J Vasc Surg; 2001 Oct; 34(4):577-80. PubMed ID: 11668307 [TBL] [Abstract][Full Text] [Related]
14. The capture of visible debris by distal cerebral protection filters during carotid artery stenting: Is it predictable? Sprouse LR; Peeters P; Bosiers M J Vasc Surg; 2005 Jun; 41(6):950-5. PubMed ID: 15944592 [TBL] [Abstract][Full Text] [Related]
15. What have we learned from the Imaging in Carotid Angioplasty and Risk of Stroke (ICAROS) study? Biasi GM; Froio A; Deleo G; Piazzoni C; Camesasca V Vascular; 2004 Jan; 12(1):62-8. PubMed ID: 15127857 [TBL] [Abstract][Full Text] [Related]
16. Carotid artery stenting with proximal cerebral protection for patients with angiographic appearance of string sign. Nikas DN; Ghany MA; Stabile E; Sorropago G; Saccá S; Favero L; Zakaryan N; Reimers B; Rubino P JACC Cardiovasc Interv; 2010 Mar; 3(3):298-304. PubMed ID: 20298988 [TBL] [Abstract][Full Text] [Related]
17. Carotid stenting with filter protection. Correlation of ACT values with angiographic and histopathologic findings. Castellan L; Causin F; Danieli D; Perini S J Neuroradiol; 2003 Mar; 30(2):103-8. PubMed ID: 12717296 [TBL] [Abstract][Full Text] [Related]
18. The SPIDER Embolic Protection Device performance evaluation in the carotid artery during percutaneous transluminal angioplasty and or stenting. Cremonesi A J Invasive Cardiol; 2005 Sep; 17(9):463-7. PubMed ID: 16145232 [TBL] [Abstract][Full Text] [Related]
19. Efficacy of a nitinol filter device in the prevention of embolic events during carotid interventions. Cremonesi A; Castriota F J Endovasc Ther; 2002 Apr; 9(2):155-9. PubMed ID: 12010093 [TBL] [Abstract][Full Text] [Related]
20. Carotid artery stenting in high surgical risk patients using the FiberNet embolic protection system: the EPIC trial results. Myla S; Bacharach JM; Ansel GM; Dippel EJ; McCormick DJ; Popma JJ Catheter Cardiovasc Interv; 2010 May; 75(6):817-22. PubMed ID: 20201102 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]