118 related articles for article (PubMed ID: 19781018)
1. Point-of-use water filtration reduces healthcare-associated infections in bone marrow transplant recipients.
Cervia JS; Farber B; Armellino D; Klocke J; Bayer RL; McAlister M; Stanchfield I; Canonica FP; Ortolano GA
Transpl Infect Dis; 2010 Jun; 12(3):238-41. PubMed ID: 19781018
[TBL] [Abstract][Full Text] [Related]
2. Removal of waterborne pathogens from liver transplant unit water taps in prevention of healthcare-associated infections: a proposal for a cost-effective, proactive infection control strategy.
Zhou ZY; Hu BJ; Qin L; Lin YE; Watanabe H; Zhou Q; Gao XD
Clin Microbiol Infect; 2014 Apr; 20(4):310-4. PubMed ID: 23879308
[TBL] [Abstract][Full Text] [Related]
3. Point-of-use water filtration reduces endemic Pseudomonas aeruginosa infections on a surgical intensive care unit.
Trautmann M; Halder S; Hoegel J; Royer H; Haller M
Am J Infect Control; 2008 Aug; 36(6):421-9. PubMed ID: 18675148
[TBL] [Abstract][Full Text] [Related]
4. Point-of-use filtration method for the prevention of fungal contamination of hospital water.
Warris A; Onken A; Gaustad P; Janssen W; van der Lee H; Verweij PE; Abrahamsen TG
J Hosp Infect; 2010 Sep; 76(1):56-9. PubMed ID: 20542590
[TBL] [Abstract][Full Text] [Related]
5. [Stenotrophomonas maltophilia and Pseudomonas aeruginosa water-associated microbiologic risk assessment in Amiens' University Hospital Centre].
Adjidé CC; De Meyer A; Weyer M; Obin O; Lamory F; Lesueur C; Trouillet L; Biendo M; Eb F; Ganry O
Pathol Biol (Paris); 2010 Apr; 58(2):e1-5. PubMed ID: 19892487
[TBL] [Abstract][Full Text] [Related]
6. Preventive efficacy and cost-effectiveness of point-of-use water filtration in a subacute care unit.
Holmes C; Cervia JS; Ortolano GA; Canonica FP
Am J Infect Control; 2010 Feb; 38(1):69-71. PubMed ID: 19709779
[TBL] [Abstract][Full Text] [Related]
7. Gram-negative bloodstream infections in hematopoietic stem cell transplant patients: the roles of needleless device use, bathing practices, and catheter care.
Toscano CM; Bell M; Zukerman C; Shelton W; Novicki TJ; Nichols WG; Corey L; Jarvis WR
Am J Infect Control; 2009 May; 37(4):327-34. PubMed ID: 19406332
[TBL] [Abstract][Full Text] [Related]
8. Epidemiology of multi-drug-resistant gram-negative bacteria: data from an university hospital over a 36-month period.
Vonberg RP; Wolter A; Chaberny IF; Kola A; Ziesing S; Suerbaum S; Gastmeier P
Int J Hyg Environ Health; 2008 Jul; 211(3-4):251-7. PubMed ID: 17980660
[TBL] [Abstract][Full Text] [Related]
9. Healthcare-associated Infections: epidemiology, prevention, and therapy.
Doshi RK; Patel G; Mackay R; Wallach F
Mt Sinai J Med; 2009 Feb; 76(1):84-94. PubMed ID: 19170222
[TBL] [Abstract][Full Text] [Related]
10. Outbreak of Stenotrophomonas maltophilia bacteremia in allogenic bone marrow transplant patients: role of severe neutropenia and mucositis.
Labarca JA; Leber AL; Kern VL; Territo MC; Brankovic LE; Bruckner DA; Pegues DA
Clin Infect Dis; 2000 Jan; 30(1):195-7. PubMed ID: 10619754
[TBL] [Abstract][Full Text] [Related]
11. Nosocomial outbreak of Legionella pneumophila serogroup 3 pneumonia in a new bone marrow transplant unit: evaluation, treatment and control.
Oren I; Zuckerman T; Avivi I; Finkelstein R; Yigla M; Rowe JM
Bone Marrow Transplant; 2002 Aug; 30(3):175-9. PubMed ID: 12189536
[TBL] [Abstract][Full Text] [Related]
12. Infection control by point-of-use water filtration in an intensive care unit - a Hungarian case study.
Barna Z; Antmann K; Pászti J; Bánfi R; Kádár M; Szax A; Németh M; Szegő E; Vargha M
J Water Health; 2014 Dec; 12(4):858-67. PubMed ID: 25473995
[TBL] [Abstract][Full Text] [Related]
13. Impact of a silver layer on the membrane of tap water filters on the microbiological quality of filtered water.
Vonberg RP; Sohr D; Bruderek J; Gastmeier P
BMC Infect Dis; 2008 Oct; 8():133. PubMed ID: 18842119
[TBL] [Abstract][Full Text] [Related]
14. Use of terminal tap water filter systems for prevention of nosocomial legionellosis.
Vonberg RP; Eckmanns T; Bruderek J; Rüden H; Gastmeier P
J Hosp Infect; 2005 Jun; 60(2):159-62. PubMed ID: 15866015
[TBL] [Abstract][Full Text] [Related]
15. Gram-negative bacteraemia (GNB) after 428 unrelated donor bone marrow transplants (UD-BMT): risk factors, prophylaxis, therapy and outcome.
Mitchell AE; Derrington P; Turner P; Hunt LP; Oakhill A; Marks DI
Bone Marrow Transplant; 2004 Feb; 33(3):303-10. PubMed ID: 14647252
[TBL] [Abstract][Full Text] [Related]
16. Gram-negative bloodstream infections.
Muñoz P; Cruz AF; Rodríguez-Créixems M; Bouza E
Int J Antimicrob Agents; 2008 Nov; 32 Suppl 1():S10-4. PubMed ID: 18775648
[TBL] [Abstract][Full Text] [Related]
17. Reusable terminal tap water filters for nosocomial legionellosis prevention.
Vonberg RP; Rotermund-Rauchenberger D; Gastmeier P
Ann Hematol; 2005 Jun; 84(6):403-5. PubMed ID: 15690178
[TBL] [Abstract][Full Text] [Related]
18. Intensive care unit-acquired Stenotrophomonas maltophilia: incidence, risk factors, and outcome.
Nseir S; Di Pompeo C; Brisson H; Dewavrin F; Tissier S; Diarra M; Boulo M; Durocher A
Crit Care; 2006; 10(5):R143. PubMed ID: 17026755
[TBL] [Abstract][Full Text] [Related]
19. Outbreaks of infectious diseases in stem cell transplant units: a silent cause of death for patients and transplant programmes.
McCann S; Byrne JL; Rovira M; Shaw P; Ribaud P; Sica S; Volin L; Olavarria E; Mackinnon S; Trabasso P; VanLint MT; Ljungman P; Ward K; Browne P; Gratwohl A; Widmer AF; Cordonnier C;
Bone Marrow Transplant; 2004 Mar; 33(5):519-29. PubMed ID: 14743201
[TBL] [Abstract][Full Text] [Related]
20. Control of endemic multidrug-resistant Gram-negative bacteria after removal of sinks and implementing a new water-safe policy in an intensive care unit.
Shaw E; Gavaldà L; Càmara J; Gasull R; Gallego S; Tubau F; Granada RM; Ciercoles P; Dominguez MA; Mañez R; Carratalà J; Pujol M
J Hosp Infect; 2018 Mar; 98(3):275-281. PubMed ID: 29104124
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]