These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 19781032)

  • 1. In vitro evaluation of the effect of fracture configuration on the mechanical properties of standard and novel interlocking nail systems in bending.
    Ting D; Cabassu JB; Guillou RP; Sinnott MT; Meyer EG; Haut RC; Déjardin LM
    Vet Surg; 2009 Oct; 38(7):881-7. PubMed ID: 19781032
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of bending direction on the mechanical behaviour of interlocking nail systems.
    Déjardin LM; Guillou RP; Ting D; Sinnott MT; Meyer E; Haut RC
    Vet Comp Orthop Traumatol; 2009; 22(4):264-9. PubMed ID: 19597632
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro mechanical evaluation of torsional loading in simulated canine tibiae for a novel hourglass-shaped interlocking nail with a self-tapping tapered locking design.
    Déjardin LM; Lansdowne JL; Sinnott MT; Sidebotham CG; Haut RC
    Am J Vet Res; 2006 Apr; 67(4):678-85. PubMed ID: 16579762
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Veterinary interlocking nailing and its augmentation for fracture repair.
    Patil DB; Adamiak Z; Piórek A
    Pol J Vet Sci; 2008; 11(2):187-91. PubMed ID: 18683549
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro mechanical comparison of screwed, bolted, and novel interlocking nail systems to buttress plate fixation in torsion and mediolateral bending.
    Lansdowne JL; Sinnott MT; Déjardin LM; Ting D; Haut RC
    Vet Surg; 2007 Jun; 36(4):368-77. PubMed ID: 17547600
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An in vitro biomechanical comparison of two interlocking-nail systems for fixation of ostectomized equine third metacarpal bones.
    Lopez MJ; Wilson DG; Trostle SS; Markel MD
    Vet Surg; 2001; 30(3):246-52. PubMed ID: 11340556
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interlocking nails and minimally invasive osteosynthesis.
    Déjardin LM; Guiot LP; von Pfeil DJ
    Vet Clin North Am Small Anim Pract; 2012 Sep; 42(5):935-62, vi. PubMed ID: 23040301
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical evaluation of a novel angle-stable interlocking nail in a gap fracture model.
    Deprey J; Blondel M; Saban C; Massenzio M; Gauthier O; Moissonnier P; Viguier E; Cachon T
    Vet Surg; 2022 Nov; 51(8):1247-1256. PubMed ID: 35675144
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An in vitro biomechanical comparison of an interlocking nail system and dynamic compression plate fixation of ostectomized equine third metacarpal bones.
    Lopez MJ; Wilson DG; Vanderby R; Markel MD
    Vet Surg; 1999; 28(5):333-40. PubMed ID: 10493637
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An in vitro biomechanical investigation of an intramedullary nailing technique for repair of third metacarpal and metatarsal fractures in neonates and foals.
    Fitch GL; Galuppo LD; Stover SM; Willits NH
    Vet Surg; 2001; 30(5):422-31. PubMed ID: 11555817
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical comparison of an interlocking nail locked with conventional bolts to extended bolts connected with a type-IA external skeletal fixator in a tibial fracture model.
    Goett SD; Sinnott MT; Ting D; Basinger RR; Haut RC; Déjardin LM
    Vet Surg; 2007 Apr; 36(3):279-86. PubMed ID: 17461954
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Interlocking Nails and Minimally Invasive Osteosynthesis.
    Déjardin LM; Perry KL; von Pfeil DJF; Guiot LP
    Vet Clin North Am Small Anim Pract; 2020 Jan; 50(1):67-100. PubMed ID: 31668598
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An in vitro biomechanical investigation of an interlocking nail system developed for buffalo tibia.
    Bhat SA; Aithal HP; Kinjavdekar P; Amarpal ; Zama MM; Gope PC; Pawde AM; Ahmad RA; Gugjoo MB
    Vet Comp Orthop Traumatol; 2014; 27(1):36-44. PubMed ID: 24146085
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.
    Weninger P; Schueller M; Jamek M; Stanzl-Tschegg S; Redl H; Tschegg EK
    Clin Biomech (Bristol); 2009 May; 24(4):379-84. PubMed ID: 19231049
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Internal fixation. Intramedullary pins, cerclage wires, and interlocking nails.
    McLaughlin R
    Vet Clin North Am Small Anim Pract; 1999 Sep; 29(5):1097-116. PubMed ID: 10503286
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion.
    Sod GA; Mitchell CF; Hubert JD; Martin GS; Gill MS
    Vet Surg; 2007 Dec; 36(8):792-9. PubMed ID: 18067621
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An in vitro biomechanical comparison of a prototype equine metacarpal dynamic compression plate fixation with double dynamic compression plate fixation of osteotomized equine third metacarpal bones.
    Sod GA; Hubert JD; Martin GS; Gill MS
    Vet Surg; 2005; 34(6):594-603. PubMed ID: 16343147
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An in vitro biomechanical comparison of a limited-contact dynamic compression plate fixation with a dynamic compression plate fixation of osteotomized equine third metacarpal bones.
    Sod GA; Hubert JD; Martin GS; Gill MS
    Vet Surg; 2005; 34(6):579-86. PubMed ID: 16343145
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An in vitro evaluation of plate luting using osteotomized equine third metacarpal bones with a limited contact-dynamic compression plate.
    Sod GA; Hubert JD; Martin GS; Gill MS
    Vet Surg; 2005; 34(6):587-93. PubMed ID: 16343146
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biological osteosynthesis versus traditional anatomic reconstruction of 20 long-bone fractures using an interlocking nail: 1994-2001.
    Horstman CL; Beale BS; Conzemius MG; Evans R R
    Vet Surg; 2004; 33(3):232-7. PubMed ID: 15104629
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.