These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
113 related articles for article (PubMed ID: 19782571)
1. Arterial occlusion caused by a non-adsorbable bone graft after open wedge tibial osteotomy. Schäfer R; Mittag F; Wünschel M Knee; 2010 Mar; 17(2):174-5. PubMed ID: 19782571 [TBL] [Abstract][Full Text] [Related]
2. Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate. Stoffel K; Stachowiak G; Kuster M Clin Biomech (Bristol); 2004 Nov; 19(9):944-50. PubMed ID: 15475127 [TBL] [Abstract][Full Text] [Related]
3. Peripheral embolism due to bone entrapment of the popliteal artery after valgus osteotomy: a case report. Rittig K; Fenchel M; Greipel N; Häring HU; Balletshofer B J Vasc Interv Radiol; 2007 May; 18(5):677-80. PubMed ID: 17494852 [TBL] [Abstract][Full Text] [Related]
4. Comparison of theoretical fixation stability of three devices employed in medial opening wedge high tibial osteotomy: a finite element analysis. Golovakhа ML; Orljanski W; Benedetto KP; Panchenko S; Büchler P; Henle P; Aghayev E BMC Musculoskelet Disord; 2014 Jul; 15():230. PubMed ID: 25012591 [TBL] [Abstract][Full Text] [Related]
5. Bovine xenograft locking Puddu plate versus tricalcium phosphate spacer non-locking Puddu plate in opening-wedge high tibial osteotomy: a prospective double-cohort study. Maffulli N; Loppini M; Longo UG; Denaro V; Oliva F Int Orthop; 2013 May; 37(5):819-26. PubMed ID: 23412369 [TBL] [Abstract][Full Text] [Related]
7. The short-term follow-up results of open wedge high tibial osteotomy with using an Aescula open wedge plate and an allogenic bone graft: the minimum 1-year follow-up results. Lee SC; Jung KA; Nam CH; Jung SH; Hwang SH Clin Orthop Surg; 2010 Mar; 2(1):47-54. PubMed ID: 20191001 [TBL] [Abstract][Full Text] [Related]
8. [Opening-wedge osteotomy of the proximal tibia]. Prix R Acta Chir Orthop Traumatol Cech; 2005; 72(5):308-12. PubMed ID: 16316607 [TBL] [Abstract][Full Text] [Related]
9. Beta-tricalcium phosphate shows superior absorption rate and osteoconductivity compared to hydroxyapatite in open-wedge high tibial osteotomy. Onodera J; Kondo E; Omizu N; Ueda D; Yagi T; Yasuda K Knee Surg Sports Traumatol Arthrosc; 2014 Nov; 22(11):2763-70. PubMed ID: 24045917 [TBL] [Abstract][Full Text] [Related]
10. Pseudoaneurysm of the popliteal artery complicating medial opening wedge high tibial osteotomy. Shenoy PM; Oh HK; Choi JY; Yoo SH; Han SB; Yoon JR; Koo JS; Nha KW Orthopedics; 2009 Jun; 32(6):442. PubMed ID: 19634816 [TBL] [Abstract][Full Text] [Related]
11. Injury risk to extraosseous knee vasculature during osteotomies: a cadaveric study with CT and dissection analysis. Bisicchia S; Rosso F; Pizzimenti MA; Rungprai C; Goetz JE; Amendola A Clin Orthop Relat Res; 2015 Mar; 473(3):1030-9. PubMed ID: 25337978 [TBL] [Abstract][Full Text] [Related]
12. Early complications after high tibial osteotomy: a comparison of two techniques. van den Bekerom MP; Patt TW; Kleinhout MY; van der Vis HM; Albers GH J Knee Surg; 2008 Jan; 21(1):68-74. PubMed ID: 18300676 [TBL] [Abstract][Full Text] [Related]
13. Adverse event rates and classifications in medial opening wedge high tibial osteotomy. Martin R; Birmingham TB; Willits K; Litchfield R; Lebel ME; Giffin JR Am J Sports Med; 2014 May; 42(5):1118-26. PubMed ID: 24634450 [TBL] [Abstract][Full Text] [Related]
14. Clinical study of the novel FlexitSystem implant for high tibial open wedge osteotomy. Van Egmond N; Van De Groes SA; Van Kampen A Acta Orthop Belg; 2019 Sep; 85(3):381-386. PubMed ID: 31677636 [TBL] [Abstract][Full Text] [Related]
15. High complication rate after biplanar open wedge high tibial osteotomy stabilized with a new spacer plate (Position HTO plate) without bone substitute. Schröter S; Gonser CE; Konstantinidis L; Helwig P; Albrecht D Arthroscopy; 2011 May; 27(5):644-52. PubMed ID: 21663721 [TBL] [Abstract][Full Text] [Related]
16. Stability of medial opening wedge high tibial osteotomy: a failure analysis. Nelissen EM; van Langelaan EJ; Nelissen RG Int Orthop; 2010 Feb; 34(2):217-23. PubMed ID: 19189104 [TBL] [Abstract][Full Text] [Related]
17. Complications Associated With Medial Opening-Wedge High Tibial Osteotomy Using a Locking Plate: A Multicenter Study. Han SB; In Y; Oh KJ; Song KY; Yun ST; Jang KM J Arthroplasty; 2019 Mar; 34(3):439-445. PubMed ID: 30503322 [TBL] [Abstract][Full Text] [Related]
18. High tibial osteotomy with Puddu plate for the treatment of varus gonarthrosis. Asik M; Sen C; Kilic B; Goksan SB; Ciftci F; Taser OF Knee Surg Sports Traumatol Arthrosc; 2006 Oct; 14(10):948-54. PubMed ID: 16607564 [TBL] [Abstract][Full Text] [Related]
19. Changes in posterior tibial slope angle in patients undergoing open-wedge high tibial osteotomy for varus gonarthrosis. Ozel O; Yucel B; Mutlu S; Orman O; Mutlu H Knee Surg Sports Traumatol Arthrosc; 2017 Jan; 25(1):314-318. PubMed ID: 25763850 [TBL] [Abstract][Full Text] [Related]
20. Complications associated with opening wedge high tibial osteotomy--A review of the literature and of 15 years of experience. Woodacre T; Ricketts M; Evans JT; Pavlou G; Schranz P; Hockings M; Toms A Knee; 2016 Mar; 23(2):276-82. PubMed ID: 26596554 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]