167 related articles for article (PubMed ID: 19784618)
1. [Modular noncemented femoral stem system in revision total hip arthroplasty].
Schofer MD; Efe T; Heyse TJ; Timmesfeld N; Velte R; Hinrichs F; Schmitt J
Orthopade; 2010 Feb; 39(2):209-16. PubMed ID: 19784618
[TBL] [Abstract][Full Text] [Related]
2. Stay Short or Go Long in Revision Total Hip Arthroplasty With Paprosky Type II Femoral Defects: A Comparative Study With the Use of an Uncemented Distal Fixating Modular Stem and a Primary Monobloc Conical Stem With 5-Year Follow-Up.
Willems JH; Smulders K; Innocenti M; Bosker BH; van Hellemondt GG
J Arthroplasty; 2022 Nov; 37(11):2239-2246. PubMed ID: 35537612
[TBL] [Abstract][Full Text] [Related]
3. Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty. Apropos of 106 cases.
Beldame J; Carreras F; Oger P; Beaufils P
Orthop Traumatol Surg Res; 2009 Nov; 95(7):478-90. PubMed ID: 19801209
[TBL] [Abstract][Full Text] [Related]
4. Nonmodular Tapered Fluted Titanium Stems Osseointegrate Reliably at Short Term in Revision THAs.
Sandiford NA; Garbuz DS; Masri BA; Duncan CP
Clin Orthop Relat Res; 2017 Jan; 475(1):186-192. PubMed ID: 27672012
[TBL] [Abstract][Full Text] [Related]
5. Mid-Term Results of Modular Tapered Femoral Stems in Revision Total Hip Arthroplasty.
Marfo KA; Berend KR; Morris MJ; Adams JB; Lombardi AV
Surg Technol Int; 2019 Nov; 35():295-300. PubMed ID: 31087320
[TBL] [Abstract][Full Text] [Related]
6. High rate of fracture in the cementless modular Extrême™ (Mark I) femoral prosthesis in revision total hip arthroplasty: 33 cases at more than 5 years' follow-up.
Benoist J; Lambotte JC; Polard JL; Huten D
Orthop Traumatol Surg Res; 2013 Dec; 99(8):915-21. PubMed ID: 24211127
[TBL] [Abstract][Full Text] [Related]
7. Total hip arthroplasty in severe segmental femoral bone loss situations: use of a reconstruction modular stem design (JVC IX). Retrospective study of 23 cases.
Bertani A; Helix M; Louis ML; Rochwerger A; Curvale G
Orthop Traumatol Surg Res; 2009 Nov; 95(7):491-7. PubMed ID: 19833568
[TBL] [Abstract][Full Text] [Related]
8. Complex revision total hip arthroplasty with modular stems at a mean of 14 years.
McCarthy JC; Lee JA
Clin Orthop Relat Res; 2007 Dec; 465():166-9. PubMed ID: 17891035
[TBL] [Abstract][Full Text] [Related]
9. Osteointegration of an uncemented modular revision stem implanted during revision hip surgery.
Šponer P; Kučera T; Urban K; Zítko D; Diaz-Garcia D; Grinac M
Acta Medica (Hradec Kralove); 2014; 57(3):105-11. PubMed ID: 25649365
[TBL] [Abstract][Full Text] [Related]
10. [Cement-free diaphyseal fixation principle for hip shaft exchange in large bone defects--analysis of 12 years experience with the Wagner revision shaft].
Böhm P; Bischel O
Z Orthop Ihre Grenzgeb; 2001; 139(3):229-39. PubMed ID: 11486626
[TBL] [Abstract][Full Text] [Related]
11. Femoral revision with the Wagner SL revision stem : evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years.
Böhm P; Bischel O
J Bone Joint Surg Am; 2001 Jul; 83(7):1023-31. PubMed ID: 11451971
[TBL] [Abstract][Full Text] [Related]
12. Mid-term outcome of a modular, cementless, proximally hydroxyapatite-coated, anatomic femoral stem.
Cossetto DJ; Goudar A
J Orthop Surg (Hong Kong); 2012 Dec; 20(3):322-6. PubMed ID: 23255638
[TBL] [Abstract][Full Text] [Related]
13. Bicortical Contact Predicts Subsidence of Modular Tapered Stems in Revision Total Hip Arthroplasty.
Moriarty P; Sheridan GA; Wong L; Guerin S; Gul R; Harty JA
J Arthroplasty; 2020 Aug; 35(8):2195-2199. PubMed ID: 32327285
[TBL] [Abstract][Full Text] [Related]
14. A 3- to 18-Year Follow-Up of Revision Total Hip Arthroplasty With Impacted Bone Allografts and Cemented Lubinus SP II Stem. Clinical, Radiographic, and Survivorship Analysis With Comparison to the Literature.
Stigbrand H; Ullmark G
J Arthroplasty; 2017 Sep; 32(9):2810-2814. PubMed ID: 28529108
[TBL] [Abstract][Full Text] [Related]
15. [The Role of a Modular Universal Tumour and Revision System (MUTARS®) in Lower Limb Endoprosthetic Revision Surgery - Outcome Analysis of 25 Patients].
Schmolders J; Koob S; Schepers P; Gravius S; Wirtz DC; Burger C; Pennekamp PH; Strauss AC
Z Orthop Unfall; 2017 Feb; 155(1):61-66. PubMed ID: 27632667
[No Abstract] [Full Text] [Related]
16. Midterm Outcomes and Frequency of Osteolysis of Total Hip Arthroplasty Using Cementless Modular Stem for Asian Patients.
Sato A; Okuda N; Tsukada S; Kimura A; Kase M; Matsubara M
J Arthroplasty; 2020 Mar; 35(3):811-817. PubMed ID: 31685396
[TBL] [Abstract][Full Text] [Related]
17. Uncemented femoral revision arthroplasty using the modular revision prosthesis MRP-TITAN revision stem.
Mumme T; Müller-Rath R; Andereya S; Wirtz DC
Oper Orthop Traumatol; 2007 Mar; 19(1):56-77. PubMed ID: 17345027
[TBL] [Abstract][Full Text] [Related]
18. Radiographic and Clinical Outcomes of Modular Tapered Fluted Stems for Femoral Revision for Paprosky III and IV Femoral Defects or Vancouver B2 and B3 Femoral Fractures.
Otero JE; Martin JR; Rowe TM; Odum SM; Mason JB
J Arthroplasty; 2020 Apr; 35(4):1069-1073. PubMed ID: 31870582
[TBL] [Abstract][Full Text] [Related]
19. [Titanium modular revision prosthesis stem in revision hip prosthesis].
Schuh A; Holzwarth U; Zeiler G
Orthopade; 2004 Jan; 33(1):63-7. PubMed ID: 14747912
[TBL] [Abstract][Full Text] [Related]
20. Revision total hip arthroplasty in patients with extensive proximal femoral bone loss using a fluted tapered modular femoral component.
Amanatullah DF; Howard JL; Siman H; Trousdale RT; Mabry TM; Berry DJ
Bone Joint J; 2015 Mar; 97-B(3):312-7. PubMed ID: 25737513
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]