BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 19786405)

  • 1. Correlation between range of motion and implant fracture: a 5 year follow-up of 72 joints in 18 patients in a randomized study comparing Swanson and Avanta/Sutter MCP silicone prosthesis.
    Tägil M; Geijer M; Malcus P; Kopylov P
    J Hand Surg Eur Vol; 2009 Dec; 34(6):743-7. PubMed ID: 19786405
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Avanta versus Swanson silicone implants in the MCP joint--a prospective, randomized comparison of 30 patients followed for 2 years.
    Möller K; Sollerman C; Geijer M; Kopylov P; Tägil M
    J Hand Surg Br; 2005 Feb; 30(1):8-13. PubMed ID: 15620485
    [TBL] [Abstract][Full Text] [Related]  

  • 3. NeuFlex and Swanson metacarpophalangeal implants for rheumatoid arthritis: prospective randomized, controlled clinical trial.
    Escott BG; Ronald K; Judd MG; Bogoch ER
    J Hand Surg Am; 2010 Jan; 35(1):44-51. PubMed ID: 20117307
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Survival and complications are similar after Swanson and Sutter implant replacement of metacarpophalangeal joints in patients with rheumatoid arthritis.
    Parkkila TJ; Belt EA; Hakala M; Kautiainen HJ; Leppilahti J
    Scand J Plast Reconstr Surg Hand Surg; 2006; 40(1):49-53. PubMed ID: 16428214
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Metacarpophalangeal joint mechanics after 3 different silicone arthroplasties.
    Weiss AP; Moore DC; Infantolino C; Crisco JJ; Akelman E; McGovern RD
    J Hand Surg Am; 2004 Sep; 29(5):796-803. PubMed ID: 15465227
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Proximal interphalangeal joint silicone arthroplasty--comparison of Swanson and NeuFlex implants using a new evaluation score].
    Stahlenbrecher A; Hoch J
    Handchir Mikrochir Plast Chir; 2009 Jun; 41(3):156-65. PubMed ID: 19533570
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Long-Term Implant Fracture Rates Following Silicone Metacarpophalangeal Joint Arthroplasty in Rheumatoid Arthritis.
    Koenuma N; Ikari K; Oh K; Iwakura N; Okazaki K
    J Hand Surg Am; 2024 May; 49(5):443-449. PubMed ID: 38402479
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Swanson and Sutter metacarpophalangeal arthroplasties in patients with rheumatoid arthritis: a prospective and randomized trial.
    Parkkila T; Belt EA; Hakala M; Kautiainen H; Leppilahti J
    J Hand Surg Am; 2005 Nov; 30(6):1276-81. PubMed ID: 16344188
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bioreconstructive poly-L/D-lactide implant compared with Swanson prosthesis in metacarpophalangeal joint arthroplasty in rheumatoid patients: a randomized clinical trial.
    Honkanen PB; Tiihonen R; Skyttä ET; Ikävalko M; Lehto MU; Konttinen YT
    J Hand Surg Eur Vol; 2010 Nov; 35(9):746-53. PubMed ID: 20627902
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hand appearance as a patient motivation for surgery and a determinant of satisfaction with metacarpophalangeal joint arthroplasty for rheumatoid arthritis.
    Bogoch ER; Escott BG; Ronald K
    J Hand Surg Am; 2011 Jun; 36(6):1007-1014.e1-4. PubMed ID: 21530103
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Early results of NeuFlex silastic implant in MCP arthroplasty].
    Schindele S; Herren D; Flury M; Simmen BR
    Handchir Mikrochir Plast Chir; 2005 Feb; 37(1):13-7. PubMed ID: 15744652
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High Fracture Rate of AVANTA Silicone Implant Following Arthroplasty of the Thumb MCP Joint of Rheumatoid Arthritis Patients with Boutonniere Deformities.
    Kaneda D; Nishida K; Nasu Y; Nakahara R; Harada R; Hotta Y; Naniwa S; Ozaki T
    Acta Med Okayama; 2024 Feb; 78(1):71-78. PubMed ID: 38419317
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High implant fracture incidence with Sutter silicone metacarpophalangeal joint arthroplasty.
    Bass RL; Stern PJ; Nairus JG
    J Hand Surg Am; 1996 Sep; 21(5):813-8. PubMed ID: 8891979
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Prosthetics of metacarpophalangeal joints].
    Hilker A; Miehlke RK; Schmidt K
    Z Rheumatol; 2007 Sep; 66(5):366-75. PubMed ID: 17717677
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Objective functional outcomes and patient satisfaction after silicone metacarpophalangeal arthroplasty for rheumatoid arthritis.
    Waljee JF; Chung KC
    J Hand Surg Am; 2012 Jan; 37(1):47-54. PubMed ID: 22196292
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Results of revision metacarpophalangeal joint surgery in rheumatoid patients following previous silicone arthroplasty.
    Burgess SD; Kono M; Stern PJ
    J Hand Surg Am; 2007 Dec; 32(10):1506-12. PubMed ID: 18070636
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Is Swanson prosthesis better than Sutter prosthesis for metacarpophalangeal joint arthroplasty? A meta-analysis.
    Zhang H; Xue D; Yu J
    J Plast Surg Hand Surg; 2015 Feb; 49(1):45-51. PubMed ID: 25166510
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Silastic implant arthroplasty of the second to fifth metacarpophalangeal joints in rheumatoid arthritis].
    Dobiás J; Pech J; Popelka S
    Acta Chir Orthop Traumatol Cech; 2007 Aug; 74(4):278-86. PubMed ID: 17877946
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Silicone arthroplasty for nonrheumatic metacarpophalangeal joint arthritis.
    Neral MK; Pittner DE; Spiess AM; Imbriglia JE
    J Hand Surg Am; 2013 Dec; 38(12):2412-8. PubMed ID: 24183404
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Silicone implant arthroplasty in patients with idiopathic osteoarthritis of the metacarpophalangeal joint.
    Rettig LA; Luca L; Murphy MS
    J Hand Surg Am; 2005 Jul; 30(4):667-72. PubMed ID: 16039355
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.