313 related articles for article (PubMed ID: 19789201)
1. Development of improved free-air ionisation chamber as absolute dosimetry standard for low-energy X rays in INER.
Chu CH; Kuan WP; Kurosawa T; Lin UT; Chen IJ; Chen WL
Radiat Prot Dosimetry; 2010 Feb; 138(2):99-106. PubMed ID: 19789201
[TBL] [Abstract][Full Text] [Related]
2. Effect of the diaphragm of free-air ionisation chamber for X-ray air-kerma measurements.
Kurosawa T; Takata N; Saito N
Radiat Prot Dosimetry; 2011 Jul; 146(1-3):195-7. PubMed ID: 21498414
[TBL] [Abstract][Full Text] [Related]
3. Correction factors for the INER-improved free-air ionization chambers calculated with the Monte Carlo method.
Lin UT; Chu CH
Appl Radiat Isot; 2006 May; 64(5):608-14. PubMed ID: 16427292
[TBL] [Abstract][Full Text] [Related]
4. Comparison of the NIST and BIPM Medium-Energy X-Ray Air-Kerma Measurements.
Burns DT; O'Brien M; Lamperti P; Boutillon M
J Res Natl Inst Stand Technol; 2003; 108(5):383-9. PubMed ID: 27413616
[TBL] [Abstract][Full Text] [Related]
5. Corrections to air kerma and exposure measured with free air ionisation chambers for charge of photoelectrons, Compton electrons and Auger electrons.
Takata N; Begum A
Radiat Prot Dosimetry; 2008; 130(4):410-8. PubMed ID: 18397932
[TBL] [Abstract][Full Text] [Related]
6. Air-kerma determination using a variable-volume cavity ionization chamber standard.
Burns DT; Kessler C; Roger P
Phys Med Biol; 2007 Dec; 52(23):7125-35. PubMed ID: 18029997
[TBL] [Abstract][Full Text] [Related]
7. Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy.
Hiatt JR; Rivard MJ; Hughes HG
Med Phys; 2016 Mar; 43(3):1119-29. PubMed ID: 26936699
[TBL] [Abstract][Full Text] [Related]
8. Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to 60Co.
Snow JR; Micka JA; DeWerd LA
Med Phys; 2013 Apr; 40(4):041711. PubMed ID: 23556881
[TBL] [Abstract][Full Text] [Related]
9. Comparison of the NIST and BIPM Standards for Air Kerma in Medium-Energy X-Rays.
Burns DT; O'Brien M
J Res Natl Inst Stand Technol; 2006; 111(5):385-91. PubMed ID: 27274940
[TBL] [Abstract][Full Text] [Related]
10. Protocol for X-ray dosimetry in radiobiology.
Zoetelief J; Broerse JJ; Davies RW; Octave-Prignot M; Rezvani M; Vergara JC; Toni MP
Int J Radiat Biol; 2001 Jul; 77(7):817-35. PubMed ID: 11454282
[TBL] [Abstract][Full Text] [Related]
11. Novel approach for the Monte Carlo calculation of free-air chamber correction factors.
Mainegra-Hing E; Reynaert N; Kawrakow I
Med Phys; 2008 Aug; 35(8):3650-60. PubMed ID: 18777925
[TBL] [Abstract][Full Text] [Related]
12. CALIBRATION METHOD AND ABSOLUTE MEASUREMENTS OF AIR KERMA OF DIAGNOSTIC X-RAY REFERENCE QUALITIES USING A FREE-AIR IONISATION CHAMBER.
Zhao R; Wu J; Wen Y; Lv Y; Guo B; Liao Z
Radiat Prot Dosimetry; 2021 Nov; 197(1):28-35. PubMed ID: 34718819
[TBL] [Abstract][Full Text] [Related]
13. The NMIJ air kerma primary standard for high energy x-ray beams in 300-450 kV.
Ishii J; Kurosawa T; Masahiro K
Biomed Phys Eng Express; 2021 Dec; 8(1):. PubMed ID: 34847537
[TBL] [Abstract][Full Text] [Related]
14. Conception and realization of a parallel-plate free-air ionization chamber for the absolute dosimetry of an ultrasoft X-ray beam.
Groetz JE; Ounoughi N; Mavon C; Belafrites A; Fromm M
Rev Sci Instrum; 2014 Aug; 85(8):083304. PubMed ID: 25173259
[TBL] [Abstract][Full Text] [Related]
15. The determination of beam quality correction factors: Monte Carlo simulations and measurements.
González-Castaño DM; Hartmann GH; Sánchez-Doblado F; Gómez F; Kapsch RP; Pena J; Capote R
Phys Med Biol; 2009 Aug; 54(15):4723-41. PubMed ID: 19622853
[TBL] [Abstract][Full Text] [Related]
16. Thimble ionization chambers in medium-energy x-ray beams and the role of constructive details of the central electrode: Monte Carlo simulations and measurements.
Ubrich F; Wulff J; Kranzer R; Zink K
Phys Med Biol; 2008 Sep; 53(18):4893-906. PubMed ID: 18711244
[TBL] [Abstract][Full Text] [Related]
17. DEVELOPMENT OF AN IONIZATION CHAMBER FOR LOW AND MEDIUM ENERGY PHOTON DOSIMETRY.
Singh SK; Kulkarni MS
Radiat Prot Dosimetry; 2018 Dec; 182(2):215-220. PubMed ID: 29660104
[TBL] [Abstract][Full Text] [Related]
18. Measurement of air kerma rates for 6- to 7-MeV high-energy gamma-ray field by ionisation chamber and build-up plate.
Kowatari M; Tanimura Y; Tsutsumi M
Radiat Prot Dosimetry; 2014 Dec; 162(4):446-58. PubMed ID: 24446508
[TBL] [Abstract][Full Text] [Related]
19. Comparison of ionization chamber efficiencies for activity measurements.
Schrader H; Svec A
Appl Radiat Isot; 2004; 60(2-4):369-78. PubMed ID: 14987670
[TBL] [Abstract][Full Text] [Related]
20. Comparison of exposure standards in the mammography x-ray region.
Coletti JG; Pearson DW; DeWerd LA; O'Brien CM; Lamperti PJ
Med Phys; 1997 Aug; 24(8):1263-7. PubMed ID: 9284250
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]