These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 19791962)

  • 1. Design and experimental tests of a novel neutron spin analyzer for wide angle spin echo spectrometers.
    Fouquet P; Farago B; Andersen KH; Bentley PM; Pastrello G; Sutton I; Thaveron E; Thomas F; Moskvin E; Pappas C
    Rev Sci Instrum; 2009 Sep; 80(9):095105. PubMed ID: 19791962
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Neutron resonance spin-echo upgrade at the three-axis spectrometer FLEXX.
    Groitl F; Keller T; Quintero-Castro DL; Habicht K
    Rev Sci Instrum; 2015 Feb; 86(2):025110. PubMed ID: 25725891
    [TBL] [Abstract][Full Text] [Related]  

  • 3. GINA--a polarized neutron reflectometer at the Budapest Neutron Centre.
    Bottyán L; Merkel DG; Nagy B; Füzi J; Sajti S; Deák L; Endrőczi G; Petrenko AV; Major J
    Rev Sci Instrum; 2013 Jan; 84(1):015112. PubMed ID: 23387700
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radial spin echo small-angle neutron scattering method: concept and performance.
    Kadletz E; Bouwman WG; Pappas C
    J Appl Crystallogr; 2022 Oct; 55(Pt 5):1072-1084. PubMed ID: 36249505
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The use of symmetry to correct Larmor phase aberrations in spin echo scattering angle measurement.
    Pynn R; Lee WT; Stonaha P; Shah VR; Washington AL; Kirby BJ; Majkrzak CF; Maranville BB
    Rev Sci Instrum; 2008 Jun; 79(6):063901. PubMed ID: 18601411
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Polarization optimization of spin-echo small angle scattering instruments.
    Rekveldt MT; Duif CP; Kraan WH; Plomp J; Bouwman WG
    Rev Sci Instrum; 2008 Jan; 79(1):015113. PubMed ID: 18248072
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Spin exchange optical pumping based polarized 3He filling station for the Hybrid Spectrometer at the Spallation Neutron Source.
    Jiang CY; Tong X; Brown DR; Culbertson H; Graves-Brook MK; Hagen ME; Kadron B; Lee WT; Robertson JL; Winn B
    Rev Sci Instrum; 2013 Jun; 84(6):065108. PubMed ID: 23822379
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Superconducting magnetic Wollaston prism for neutron spin encoding.
    Li F; Parnell SR; Hamilton WA; Maranville BB; Wang T; Semerad R; Baxter DV; Cremer JT; Pynn R
    Rev Sci Instrum; 2014 May; 85(5):053303. PubMed ID: 24880360
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Additively Manufactured NdFeB Polyphenylene Sulfide Halbach Magnets to Generate Variable Magnetic Fields for Neutron Reflectometry.
    Lamichhane TN; Charlton TR; Andrews B; Malaviya D; Pathak AK; Ambaye H; Doucet M; Lauter V; Katsaras J; Post BK; Paranthaman MP
    3D Print Addit Manuf; 2022 Aug; 9(4):245-254. PubMed ID: 36654742
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simulations of foil-based spin-echo (modulated) small-angle neutron scattering with a sample using
    Bouwman WG; Knudsen EB; Udby L; Willendrup P
    J Appl Crystallogr; 2021 Feb; 54(Pt 1):195-202. PubMed ID: 33833647
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neutron resonance spin flippers: static coils manufactured by electrical discharge machining.
    Martin N; Wagner JN; Dogu M; Fuchs C; Kredler L; Böni P; Häußler W
    Rev Sci Instrum; 2014 Jul; 85(7):073902. PubMed ID: 25085147
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design and commissioning of a high magnetic field muon spin relaxation spectrometer at the ISIS pulsed neutron and muon source.
    Lord JS; McKenzie I; Baker PJ; Blundell SJ; Cottrell SP; Giblin SR; Good J; Hillier AD; Holsman BH; King PJ; Lancaster T; Mitchell R; Nightingale JB; Owczarkowski M; Poli S; Pratt FL; Rhodes NJ; Scheuermann R; Salman Z
    Rev Sci Instrum; 2011 Jul; 82(7):073904. PubMed ID: 21806196
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Neutron spin evolution through broadband current sheet spin flippers.
    Stonaha P; Hendrie J; Lee WT; Pynn R
    Rev Sci Instrum; 2013 Oct; 84(10):105113. PubMed ID: 24182169
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A spin- and angle-resolving photoelectron spectrometer.
    Berntsen MH; Palmgren P; Leandersson M; Hahlin A; Ahlund J; Wannberg B; Månsson M; Tjernberg O
    Rev Sci Instrum; 2010 Mar; 81(3):035104. PubMed ID: 20370210
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prototype of the novel CAMEA concept-A backend for neutron spectrometers.
    Markó M; Groitl F; Birk JO; Freeman PG; Lefmann K; Christensen NB; Niedermayer C; Jurányi F; Lass J; Hansen A; Rønnow HM
    Rev Sci Instrum; 2018 Jan; 89(1):015105. PubMed ID: 29390677
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Spin echo small angle neutron scattering using a continuously pumped (3)He neutron polarisation analyser.
    Parnell SR; Washington AL; Li K; Yan H; Stonaha P; Li F; Wang T; Walsh A; Chen WC; Parnell AJ; Fairclough JP; Baxter DV; Snow WM; Pynn R
    Rev Sci Instrum; 2015 Feb; 86(2):023902. PubMed ID: 25725858
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-q-resolution neutron scattering technique using triple-axis spectrometers.
    Xu G; Gehring PM; Ghosh VJ; Shirane G
    Acta Crystallogr A; 2004 Nov; 60(Pt 6):598-603. PubMed ID: 15507743
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Concepts and Engineering Aspects of a Neutron Resonance Spin-Echo Spectrometer for the National Institute of Standards and Technology Center for Neutron Research.
    Cook JC
    J Res Natl Inst Stand Technol; 2014; 119():55-211. PubMed ID: 26601027
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Long-time stability of a low-energy electron diffraction spin polarization analyzer for magnetic imaging.
    Lofink F; Hankemeier S; Frömter R; Kirschner J; Oepen HP
    Rev Sci Instrum; 2012 Feb; 83(2):023708. PubMed ID: 22380100
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative radiography of magnetic fields using neutron spin phase imaging.
    Piegsa FM; van den Brandt B; Hautle P; Kohlbrecher J; Konter JA
    Phys Rev Lett; 2009 Apr; 102(14):145501. PubMed ID: 19392450
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.