  • 1. An uncommon cause of myopotentials leading to inappropriate ICD therapy.
    Chawla P; Hanon S; Lam P; Schweitzer P
    Pacing Clin Electrophysiol; 2009 Dec; 32(12):1584-6. PubMed ID: 19793368
    [No Abstract]   [Full Text] [Related]  

  • 2. Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms.
    Kowalski M; Ellenbogen KA; Wood MA; Friedman PL
    Europace; 2008 Aug; 10(8):914-7. PubMed ID: 18565976
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Inappropriate sensing of pectoral myopotentials by an implantable cardioverter defibrillator system.
    Karanam S; John RM
    Pacing Clin Electrophysiol; 2004 May; 27(5):688-9. PubMed ID: 15125734
    [TBL] [Abstract][Full Text] [Related]  

  • 4. T-wave oversensing in implantable cardiac defibrillators is due to technical failure of device sensing.
    Gilliam FR
    J Cardiovasc Electrophysiol; 2006 May; 17(5):553-6. PubMed ID: 16684033
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Inadequate therapies with implantable cardioverter-defibrillators--incidence, etiology, predictive factors and preventive strategies].
    Weber M; Block M; Brunn J; Bänsch D; Böcker D; Hammel D; Gietzen F; Breithardt G
    Z Kardiol; 1996 Nov; 85(11):809-19. PubMed ID: 9064943
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Inappropriate implantable cardioverter-defibrillator shock due to external alternating current leak: report of two cases.
    Chan NY; Wai-Ling Ho L
    Europace; 2005 Mar; 7(2):193-6. PubMed ID: 15763537
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Far-field oversensing of atrial signals: an unusual cause for very short V-V intervals and inappropriate implantable cardioverter defibrillator therapy.
    Vollmann D; Lüthje L; Zabel M
    Europace; 2008 Aug; 10(8):1009-11. PubMed ID: 18424788
    [No Abstract]   [Full Text] [Related]  

  • 8. Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias.
    Occhetta E; Bortnik M; Magnani A; Francalacci G; Marino P
    Europace; 2006 Oct; 8(10):863-9. PubMed ID: 16916859
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Strategy to eliminate inappropriate shocks secondary to T-wave oversensing in a biventricular ICD.
    Silver JS; Gray ME; John RM
    Pacing Clin Electrophysiol; 2009 Jan; 32(1):134-6. PubMed ID: 19140924
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Single channel ICD noise without loss of conductor circuit integrity.
    Deyell MW; Patel RK; Cooper JM
    Pacing Clin Electrophysiol; 2012 May; 35(5):616-21. PubMed ID: 21972947
    [No Abstract]   [Full Text] [Related]  

  • 11. Resolution of T-wave oversensing with implantable cardioverter defibrillator generator replacement in an adolescent.
    Tuzcu V
    Pacing Clin Electrophysiol; 2007 Jul; 30(7):929-32. PubMed ID: 17584279
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Time shift of marker legend in stored intracardiac events in three patients with the vitality 2 EL DR (model T167) and Prizm 2DR (model 1861) dual-chamber defibrillators.
    Saba S; Jain S; Bazaz R; Schwartzman D
    J Cardiovasc Electrophysiol; 2009 May; 20(5):564-7. PubMed ID: 19054249
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Unusual cause for an increase of the sensing integrity counter in a patient with inappropriate implantable cardioverter-defibrillator therapy.
    Vollmann D; Lüthje L; Zabel M
    Europace; 2007 May; 9(5):275-7. PubMed ID: 17369268
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sensing lead insulation fractures following implantable cardioverter-defibrillator placement.
    Tedder M; Anstadt MP; Tedder SD; Revishvili AS; Hegde SS; Lowe JE
    ASAIO J; 1993; 39(3):M711-4. PubMed ID: 8268630
    [TBL] [Abstract][Full Text] [Related]  

  • 15. ICD oversensing caused by TASER.
    Paninski RJ; Marshall ME; Link MS
    J Cardiovasc Electrophysiol; 2013 Jan; 24(1):101. PubMed ID: 23227948
    [No Abstract]   [Full Text] [Related]  

  • 16. Incidence and causes of inappropriate detection and therapy by implantable defibrillators of cardioversion in patients with ventricular tachyarrhythmia.
    Chen RH; Chen KP; Wang FZ; Hua W; Chen X; Zhang S
    Chin Med J (Engl); 2006 Apr; 119(7):557-63. PubMed ID: 16620696
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Myopotentials leading to ventricular fibrillation detection after advisory defibrillator generator replacement.
    Eckart RE; Hruczkowski TW; Stevenson WG; Epstein LM
    Pacing Clin Electrophysiol; 2006 Nov; 29(11):1273-6. PubMed ID: 17100683
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks.
    Tzeis S; Andrikopoulos G; Kolb C; Vardas PE
    Europace; 2008 Nov; 10(11):1256-65. PubMed ID: 18708639
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An unusual mechanism causing inappropriate implantable cardioverter defibrillator shocks: transient reduction in R-wave amplitude.
    Baranchuk A; Ribas S; Divakaramenon S; Morillo CA
    Europace; 2007 Aug; 9(8):694-6. PubMed ID: 17478463
    [TBL] [Abstract][Full Text] [Related]  

  • 20. T-wave oversensing and inappropriate shocks: a case report.
    Srivathsan K; Scott LR; Altemose GT
    Europace; 2008 May; 10(5):552-5. PubMed ID: 18442965
    [TBL] [Abstract][Full Text] [Related]  