These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
389 related articles for article (PubMed ID: 19796348)
1. The implantable cardioverter-defibrillator lead: principles, progress, and promises. Haqqani HM; Mond HG Pacing Clin Electrophysiol; 2009 Oct; 32(10):1336-53. PubMed ID: 19796348 [TBL] [Abstract][Full Text] [Related]
2. The implantable cardioverter defibrillator: modern implantation techniques and their impact on outcomes. Luceri RM; Zilo P; Weiss DN Arch Mal Coeur Vaiss; 1996 Feb; 89 Spec No 1():129-33. PubMed ID: 8734174 [TBL] [Abstract][Full Text] [Related]
3. Epicardial and pleural lead ICD systems in children and adolescents maintain functionality over 5 years. Tomaske M; Prêtre R; Rahn M; Bauersfeld U Europace; 2008 Oct; 10(10):1152-6. PubMed ID: 18701602 [TBL] [Abstract][Full Text] [Related]
4. Performance and survival of transvenous defibrillation leads: need for a European data registry. Goette A; Cantu F; van Erven L; Geelen P; Halimi F; Merino JL; Morgan JM; Europace; 2009 Jan; 11(1):31-4. PubMed ID: 19004838 [TBL] [Abstract][Full Text] [Related]
5. Clinical experience and procedural outcomes associated with the DF4 implantable cardioverter defibrillator system: the SJ4 postapproval study. Cantillon DJ; Ha K; Styperek R; Jumrussirikul P; Mirro M; Wong W; Wilkoff BL Pacing Clin Electrophysiol; 2013 Jul; 36(7):855-62. PubMed ID: 23617316 [TBL] [Abstract][Full Text] [Related]
7. Do electrical stun guns (TASER-X26) affect the functional integrity of implantable pacemakers and defibrillators? Lakkireddy D; Khasnis A; Antenacci J; Ryshcon K; Chung MK; Wallick D; Kowalewski W; Patel D; Mlcochova H; Kondur A; Vacek J; Martin D; Natale A; Tchou P Europace; 2007 Jul; 9(7):551-6. PubMed ID: 17491105 [TBL] [Abstract][Full Text] [Related]
8. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. Spencker S; Coban N; Koch L; Schirdewan A; Müller D Europace; 2009 Apr; 11(4):483-8. PubMed ID: 19103654 [TBL] [Abstract][Full Text] [Related]
9. Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms. Kowalski M; Ellenbogen KA; Wood MA; Friedman PL Europace; 2008 Aug; 10(8):914-7. PubMed ID: 18565976 [TBL] [Abstract][Full Text] [Related]
10. The azygos defibrillator lead for elevated defibrillation thresholds: implant technique, lead stability, and patient series. Cooper JA; Latacha MP; Soto GE; Garmany RG; Gleva MJ; Chen J; Faddis MN; Smith TW Pacing Clin Electrophysiol; 2008 Nov; 31(11):1405-10. PubMed ID: 18950297 [TBL] [Abstract][Full Text] [Related]
11. Does size really matter? A comparison of the Riata lead family based on size and its relation to performance. Corbisiero R; Armbruster R Pacing Clin Electrophysiol; 2008 Jun; 31(6):722-6. PubMed ID: 18507545 [TBL] [Abstract][Full Text] [Related]
12. Covering sleeves can shield the high-voltage coils from lead chatter in an integrated bipolar ICD lead. Cooper JM; Sauer WH; Garcia FC; Krautkramer MJ; Verdino RJ Europace; 2007 Feb; 9(2):137-42. PubMed ID: 17272336 [TBL] [Abstract][Full Text] [Related]
13. Implantable cardioverter-defibrillator lead failure: how weak is the link? Brinker JA Nat Clin Pract Cardiovasc Med; 2008 Dec; 5(12):758-9. PubMed ID: 18838965 [TBL] [Abstract][Full Text] [Related]
14. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture. Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874 [TBL] [Abstract][Full Text] [Related]
15. Necessity for surgical revision of defibrillator leads implanted long-term: causes and management. Eckstein J; Koller MT; Zabel M; Kalusche D; Schaer BA; Osswald S; Sticherling C Circulation; 2008 May; 117(21):2727-33. PubMed ID: 18490526 [TBL] [Abstract][Full Text] [Related]
16. Analysis of implantable defibrillator longevity under clinical circumstances: implications for device selection. Knops P; Theuns DA; Res JC; Jordaens L Pacing Clin Electrophysiol; 2009 Oct; 32(10):1276-85. PubMed ID: 19796344 [TBL] [Abstract][Full Text] [Related]
17. Implantable cardioverter defibrillator: what a hospital practitioner needs to know. Albouaini K; Mudawi T; Pyatt JR; Wright DJ Eur J Intern Med; 2009 Oct; 20(6):591-7. PubMed ID: 19782919 [TBL] [Abstract][Full Text] [Related]
18. The subcutaneous implantable cardioverter-defibrillator: should patients want one? Hauser RG J Am Coll Cardiol; 2013 Jan; 61(1):20-2. PubMed ID: 23122791 [TBL] [Abstract][Full Text] [Related]