These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 19797144)

  • 1. Implantable loop recorders for assessment of syncope: is 'Saint Thomas approach' still the best diagnostic strategy?
    Bartoletti A
    Europace; 2009 Oct; 11(10):1262-4. PubMed ID: 19797144
    [No Abstract]   [Full Text] [Related]  

  • 2. Time to manual activation of implantable loop recorders--implications for programming recording period: a 10-year single-centre experience.
    Turley AJ; Tynan MM; Plummer CJ
    Europace; 2009 Oct; 11(10):1359-61. PubMed ID: 19648151
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Are implantable loop recorders useful in detecting arrhythmias in children with unexplained syncope?
    Al Dhahri KN; Potts JE; Chiu CC; Hamilton RM; Sanatani S
    Pacing Clin Electrophysiol; 2009 Nov; 32(11):1422-7. PubMed ID: 19694968
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The utility of implantable loop recorders for diagnosing unexplained syncope in 100 consecutive patients: five-year, single-center experience.
    Inamdar V; Mehta S; Juang G; Cohen T
    J Invasive Cardiol; 2006 Jul; 18(7):313-5. PubMed ID: 16816436
    [TBL] [Abstract][Full Text] [Related]  

  • 5. How revealing are insertable loop recorders in pediatrics?
    Frangini PA; Cecchin F; Jordao L; Martuscello M; Alexander ME; Triedman JK; Walsh EP; Berul CI
    Pacing Clin Electrophysiol; 2008 Mar; 31(3):338-43. PubMed ID: 18307630
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Efficacy of implantable loop recorders in establishing symptom-rhythm correlation in patients with unexplained syncope].
    Liu ZM; Liu ZP; Guo T
    Zhonghua Xin Xue Guan Bing Za Zhi; 2006 Nov; 34(11):1009-12. PubMed ID: 17288766
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Implantable loop recorders in the investigation of unexplained syncope: a state of the art review.
    Parry SW; Matthews IG
    Heart; 2010 Oct; 96(20):1611-6. PubMed ID: 20937748
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Implantable loop recorders in the diagnosis of syncope].
    Kaess BM; Ehrlich JR
    Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):345-350. PubMed ID: 27812742
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Single-centre use of implantable loop recorders in patients with congenital heart disease.
    Kenny D; Chakrabarti S; Ranasinghe A; Chambers A; Martin R; Stuart G
    Europace; 2009 Mar; 11(3):303-7. PubMed ID: 19153088
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of the implantable loop recorder in evaluation of patients with unexplained syncope.
    Krahn AD; Klein GJ; Skanes AC; Yee R
    J Cardiovasc Electrophysiol; 2003 Sep; 14(9 Suppl):S70-3. PubMed ID: 12950523
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Implantable loop recorders of the Reveal family (Medtronic)].
    Voss F
    Herzschrittmacherther Elektrophysiol; 2016 Dec; 27(4):333-336. PubMed ID: 27878365
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Role of extended external loop recorders for the diagnosis of unexplained syncope, pre-syncope, and sustained palpitations.
    Locati ET; Vecchi AM; Vargiu S; Cattafi G; Lunati M
    Europace; 2014 Jun; 16(6):914-22. PubMed ID: 24158255
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improved arrhythmia detection in implantable loop recorders.
    Brignole M; Bellardine Black CL; Thomsen PE; Sutton R; Moya A; Stadler RW; Cao J; Messier M; Huikuri HV
    J Cardiovasc Electrophysiol; 2008 Sep; 19(9):928-34. PubMed ID: 18410328
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Utility of mobile cardiac outpatient telemetry for the diagnosis of palpitations, presyncope, syncope, and the assessment of therapy efficacy.
    Olson JA; Fouts AM; Padanilam BJ; Prystowsky EN
    J Cardiovasc Electrophysiol; 2007 May; 18(5):473-7. PubMed ID: 17343724
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Implantable loop recorders in pediatric practice.
    Bloemers BL; Sreeram N
    J Electrocardiol; 2002; 35 Suppl():131-5. PubMed ID: 12539110
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Epilepsy or syncope? An analysis of 55 consecutive patients with loss of consciousness, convulsions, falls, and no EEG abnormalities.
    Rodrigues Tda R; Sternick EB; Moreira Mda C
    Pacing Clin Electrophysiol; 2010 Jul; 33(7):804-13. PubMed ID: 20158619
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimal duration of event recording for diagnosis of arrhythmias in patients with palpitations and light-headedness in the general practice.
    Hoefman E; van Weert HC; Boer KR; Reitsma J; Koster RW; Bindels PJ
    Fam Pract; 2007 Feb; 24(1):11-3. PubMed ID: 17158181
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiac loop ECG recording: a new noninvasive diagnostic test in recurrent syncope.
    Cumbee SR; Pryor RE; Linzer M
    South Med J; 1990 Jan; 83(1):39-43. PubMed ID: 2300833
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Diagnostic Value of Implantable Loop Recorders in Elderly Adults.
    McIntyre WF; Liebrecht K; Daba L; Seifer CM
    J Am Geriatr Soc; 2016 Jun; 64(6):1370-2. PubMed ID: 27321628
    [No Abstract]   [Full Text] [Related]  

  • 20. The dual role of implantable loop recorder in patients with potentially arrhythmic symptoms: a retrospective single-center study.
    Kabra R; Gopinathannair R; Sandesara C; Messinger C; Olshansky B
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):908-12. PubMed ID: 19572867
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.