These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 19800117)

  • 1. Preparation and properties of high purity Mg-Y biomaterials.
    Peng Q; Huang Y; Zhou L; Hort N; Kainer KU
    Biomaterials; 2010 Jan; 31(3):398-403. PubMed ID: 19800117
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Time-dependent electrochemical characterization of the corrosion of a magnesium rare-earth alloy in simulated body fluids.
    Rettig R; Virtanen S
    J Biomed Mater Res A; 2008 Apr; 85(1):167-75. PubMed ID: 17688266
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro degradation and mechanical integrity of calcium-containing magnesium alloys in modified-simulated body fluid.
    Kannan MB; Raman RK
    Biomaterials; 2008 May; 29(15):2306-14. PubMed ID: 18313746
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro corrosion and biocompatibility of binary magnesium alloys.
    Gu X; Zheng Y; Cheng Y; Zhong S; Xi T
    Biomaterials; 2009 Feb; 30(4):484-98. PubMed ID: 19000636
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Critical discussion of the results from different corrosion studies of Mg and Mg alloys for biomaterial applications.
    Mueller WD; Lucia Nascimento M; Lorenzo de Mele MF
    Acta Biomater; 2010 May; 6(5):1749-55. PubMed ID: 20051271
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Degradation of magnesium and its alloys: dependence on the composition of the synthetic biological media.
    Mueller WD; de Mele MF; Nascimento ML; Zeddies M
    J Biomed Mater Res A; 2009 Aug; 90(2):487-95. PubMed ID: 18563809
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vitro and in vivo corrosion measurements of magnesium alloys.
    Witte F; Fischer J; Nellesen J; Crostack HA; Kaese V; Pisch A; Beckmann F; Windhagen H
    Biomaterials; 2006 Mar; 27(7):1013-8. PubMed ID: 16122786
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The influence of heat treatment and plastic deformation on the bio-degradation of a Mg-Y-RE alloy.
    Gunde P; Furrer A; Hänzi AC; Schmutz P; Uggowitzer PJ
    J Biomed Mater Res A; 2010 Feb; 92(2):409-18. PubMed ID: 19191312
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Composition of corrosion layers on a magnesium rare-earth alloy in simulated body fluids.
    Rettig R; Virtanen S
    J Biomed Mater Res A; 2009 Feb; 88(2):359-69. PubMed ID: 18286623
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Development of biodegradable magnesium-based biomaterials].
    Zhu S; Xu L; Huang N
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Apr; 26(2):437-9, 451. PubMed ID: 19499820
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of backward extrusion on mechanical and degradation properties of Mg-Zn biomaterial.
    Peng Q; Li X; Ma N; Liu R; Zhang H
    J Mech Behav Biomed Mater; 2012 Jun; 10():128-37. PubMed ID: 22520425
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Corrosion and other electrochemical aspects of biomaterials.
    Bundy KJ
    Crit Rev Biomed Eng; 1994; 22(3-4):139-251. PubMed ID: 8598129
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Magnesium and its alloys as orthopedic biomaterials: a review.
    Staiger MP; Pietak AM; Huadmai J; Dias G
    Biomaterials; 2006 Mar; 27(9):1728-34. PubMed ID: 16246414
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The development of binary Mg-Ca alloys for use as biodegradable materials within bone.
    Li Z; Gu X; Lou S; Zheng Y
    Biomaterials; 2008 Apr; 29(10):1329-44. PubMed ID: 18191191
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monitoring of titanium base alloys-biofluids interface.
    Popa MV; Demetrescu I; Suh SH; Vasilescu E; Drob P; Ionita D; Vasilescu C
    Bioelectrochemistry; 2007 Nov; 71(2):126-34. PubMed ID: 17409027
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Corrosion evaluation of Ti-48Al-2Cr-2Nb (at.%) in Ringer's solution.
    Delgado-Alvarado C; Sundaram PA
    Acta Biomater; 2006 Nov; 2(6):701-8. PubMed ID: 16887397
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro studies of biomedical magnesium alloys in a simulated physiological environment: a review.
    Xin Y; Hu T; Chu PK
    Acta Biomater; 2011 Apr; 7(4):1452-9. PubMed ID: 21145436
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Corrosive degradation of magnesium and its alloy as endovascular stent].
    Chen S; Lu A; Hu X; Yu D
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Dec; 28(6):1246-50. PubMed ID: 22295723
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Surface modifications of magnesium alloys for biomedical applications.
    Yang J; Cui F; Lee IS
    Ann Biomed Eng; 2011 Jul; 39(7):1857-71. PubMed ID: 21445692
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.