BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 19802834)

  • 1. Polyethylene wear debris produced in a knee simulator model: effect of crosslinking and counterface material.
    Williams PA; Brown CM; Tsukamoto R; Clarke IC
    J Biomed Mater Res B Appl Biomater; 2010 Jan; 92(1):78-85. PubMed ID: 19802834
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles.
    Ingram JH; Stone M; Fisher J; Ingham E
    Biomaterials; 2004 Aug; 25(17):3511-22. PubMed ID: 15020125
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.
    Endo MM; Barbour PS; Barton DC; Fisher J; Tipper JL; Ingham E; Stone MH
    Biomed Mater Eng; 2001; 11(1):23-35. PubMed ID: 11281576
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements.
    Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G
    Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device.
    Saikko V; Calonius O; Keränen J
    J Biomed Mater Res; 2001 Dec; 57(4):506-12. PubMed ID: 11553880
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement.
    Lancaster JG; Dowson D; Isaac GH; Fisher J
    Proc Inst Mech Eng H; 1997; 211(1):17-24. PubMed ID: 9141887
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultra-high molecular weight polyethylene wear debris generated in vivo and in laboratory tests; the influence of counterface roughness.
    Hailey JL; Ingham E; Stone M; Wroblewski BM; Fisher J
    Proc Inst Mech Eng H; 1996; 210(1):3-10. PubMed ID: 8663891
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators.
    Tipper JL; Galvin AL; Williams S; McEwen HM; Stone MH; Ingham E; Fisher J
    J Biomed Mater Res A; 2006 Sep; 78(3):473-80. PubMed ID: 16721797
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Y-TZP zirconia run against highly crosslinked UHMWPE tibial inserts: knee simulator wear and phase-transformation studies.
    Tsukamoto R; Williams PA; Clarke IC; Pezzotti G; Shoji H; Akagi M; Yamamoto K
    J Biomed Mater Res B Appl Biomater; 2008 Jul; 86(1):145-53. PubMed ID: 18161824
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wear of crosslinked polyethylene under different tribological conditions.
    Galvin A; Kang L; Tipper J; Stone M; Ingham E; Jin Z; Fisher J
    J Mater Sci Mater Med; 2006 Mar; 17(3):235-43. PubMed ID: 16555115
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
    Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
    Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Third-body abrasive wear challenge of 32 mm conventional and 44 mm highly crosslinked polyethylene liners in a hip simulator model.
    Sorimachi T; Clarke IC; Williams PA; Gustafson A; Yamamoto K
    Proc Inst Mech Eng H; 2009 Jul; 223(5):607-23. PubMed ID: 19623913
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The relative effects of radiation crosslinking and type of counterface on the wear resistance of ultrahigh-molecular-weight polyethylene.
    Bistolfi A; Bellare A
    Acta Biomater; 2011 Sep; 7(9):3398-403. PubMed ID: 21640855
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of molecular orientation and acetylene-enhanced crosslinking on the wear of UHMWPE in total artificial joints.
    Marrs H; Barton DC; Doyle C; Jones RA; Lewis EL; Ward IM; Fisher J
    J Mater Sci Mater Med; 2001 Jul; 12(7):621-8. PubMed ID: 15348255
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements.
    Schmalzried TP; Campbell P; Schmitt AK; Brown IC; Amstutz HC
    J Biomed Mater Res; 1997; 38(3):203-10. PubMed ID: 9283965
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analysis of polyethylene particles produced in different wear conditions in vitro.
    Calonius O; Saikko V
    Clin Orthop Relat Res; 2002 Jun; (399):219-30. PubMed ID: 12011713
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester.
    Baykal D; Siskey RS; Underwood RJ; Briscoe A; Kurtz SM
    Clin Orthop Relat Res; 2016 Nov; 474(11):2384-2393. PubMed ID: 27457625
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of cytotoxicity of UHMWPE wear debris.
    Rao S; Shirata K; Furukawa KS; Ushida T; Tateishi T; Kanazawa M; Katsube S; Janna S
    Biomed Mater Eng; 1999; 9(4):209-17. PubMed ID: 10674175
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Polyethylene wear characteristics in vivo and in a knee stimulator.
    Beaulé PE; Campbell PA; Walker PS; Schmalzried TP; Dorey FJ; Blunn GW; Bell CJ; Yahia L; Amstutz HC
    J Biomed Mater Res; 2002 Jun; 60(3):411-9. PubMed ID: 11920665
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements.
    Shanbhag AS; Bailey HO; Hwang DS; Cha CW; Eror NG; Rubash HE
    J Biomed Mater Res; 2000; 53(1):100-10. PubMed ID: 10634959
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.