These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
171 related articles for article (PubMed ID: 19808619)
21. Successful reposition and treatment of severe aortic paraprosthetic regurgitation after percutaneous implantation of a self-expandable biological valve. Frerker C; Bergmann M; Schewel D; Busse C; Jensen F; Schmoeckel M; Schneider C; Kuck KH; Schaefer U J Cardiovasc Med (Hagerstown); 2012 May; 13(5):346-50. PubMed ID: 20479655 [No Abstract] [Full Text] [Related]
22. Intracardiac echo imaging of a transfemoral aortic Edwards SAPIEN valve implantation in a degenerated bioprosthesis (valve-in-valve). Kefer J; Astarci P; Renkin J J Invasive Cardiol; 2010 Jul; 22(7):341-2. PubMed ID: 20603509 [No Abstract] [Full Text] [Related]
23. Aortic valve perforation following transcoronary ablation of septal hypertrophy. Galeone A; Barreda E; Choussat R; Leprince P; Pavie A Asian Cardiovasc Thorac Ann; 2012 Oct; 20(5):595-6. PubMed ID: 23087309 [TBL] [Abstract][Full Text] [Related]
24. A torn 15-year-old aortic bioprosthesis in the setting of percutaneous coronary intervention: echocardiographic diagnosis and pathologic correlation. A case report. Michelena HI; Enriquez-Sarano M; Sundt TM J Heart Valve Dis; 2009 Mar; 18(2):228-31. PubMed ID: 19455901 [TBL] [Abstract][Full Text] [Related]
25. Percutaneous closure of aortic prosthetic paravalvular regurgitation with two amplatzer septal occluders. Phillips SA; Thompson A; Abu-Halimah A; Crenshaw MH; Zhao DX; Pretorius M Anesth Analg; 2009 Feb; 108(2):437-8. PubMed ID: 19151267 [No Abstract] [Full Text] [Related]
29. Acute aortic insufficiency after blunt chest trauma: a case report. Turk T; Vural H; Ata Y; Eris C; Yavuz S J Cardiovasc Surg (Torino); 2007 Jun; 48(3):359-61. PubMed ID: 17505441 [TBL] [Abstract][Full Text] [Related]
30. Aortic regurgitation due to perforation of the right coronary cusp 10 years after implantation of a freestyle stentless bioprosthesis. Okamoto Y; Katsu M; Matsumoto M J Card Surg; 2011 Nov; 26(6):613-4. PubMed ID: 21951139 [TBL] [Abstract][Full Text] [Related]
31. Aortic valve avulsion: uncommon complication of coronary angiography. Shim CY; Lee S; Wi J; Yang WI; Ha JW; Jang Y; Chang BC; Chung N J Am Coll Cardiol; 2012 Jul; 60(2):e3. PubMed ID: 22766349 [No Abstract] [Full Text] [Related]
32. Experiences with the Toronto SPV bioprosthesis after three years follow-up. Strauch JT; Baryalei MM; Aleksic I; Dalichau H Thorac Cardiovasc Surg; 1999 Feb; 47(1):19-22. PubMed ID: 10218615 [TBL] [Abstract][Full Text] [Related]
33. Aortic valve regurgitation secondary to ectopia and atresia of the left main coronary artery. Nicolini F; Corradi D; Agostinelli A; Borrello B; Gherli T J Heart Valve Dis; 2014 Mar; 23(2):158-60. PubMed ID: 25076544 [TBL] [Abstract][Full Text] [Related]
35. Repair of aortic cusp traumatic laceration caused by cardiac catheterization. Fundarò P; Di Mattia DG; Cialfi A; Santoli C J Heart Valve Dis; 1996 May; 5(3):281-2. PubMed ID: 8793676 [TBL] [Abstract][Full Text] [Related]
36. Which available transapical transcatheter valve fits into degenerated aortic bioprostheses? Ferrari E; Marcucci C; Sulzer C; von Segesser LK Interact Cardiovasc Thorac Surg; 2010 Jul; 11(1):83-5. PubMed ID: 20395247 [TBL] [Abstract][Full Text] [Related]
37. An atypical cause of aortic valve prolapse. Okamoto Y; Matsumoto M; Inoue H Ann Thorac Surg; 2009 Sep; 88(3):994-6. PubMed ID: 19699939 [TBL] [Abstract][Full Text] [Related]
38. Two- and three-dimensional transesophageal echocardiography for aortic valve aneurysms on the right coronary cusp. Kuroda M; Takemae A; Takahashi T; Mita N; Kagaya S; Miyoshi S; Kadoi Y; Saito S Anesth Analg; 2013 Apr; 116(4):784-7. PubMed ID: 23460573 [No Abstract] [Full Text] [Related]
39. Caseous calcification of the left aortic valve cusp. Schouver ED; Lena D; Paul G; Mihoubi A; Lopez S J Card Surg; 2017 Jul; 32(7):418-419. PubMed ID: 28689373 [No Abstract] [Full Text] [Related]
40. Rare case of iatrogenic aortic valve leaflet tear following a diagnostic coronary angiogram. Madigan M; McIsaac S; Garg A; Alqahtani A; Kumar A; Atoui R J Card Surg; 2020 Jan; 35(1):204-206. PubMed ID: 31573092 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]