536 related articles for article (PubMed ID: 19811997)
1. Acoustic wave flow sensor using quartz thickness shear mode resonator.
Qin L; Zeng Z; Cheng H; Wang QM
IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Sep; 56(9):1945-54. PubMed ID: 19811997
[TBL] [Abstract][Full Text] [Related]
2. Chemical sensor based on surface acoustic wave resonator using Langmuir-Blodgett film.
Nomura T; Takebayashi R; Saitoh A
IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(5):1261-5. PubMed ID: 18244288
[TBL] [Abstract][Full Text] [Related]
3. Different experimental results for the influence of immersion angle on the resonant frequency of a quartz crystal microbalance in a liquid phase: with a comment.
Shen D; Kang Q; Li X; Cai H; Wang Y
Anal Chim Acta; 2007 Jun; 593(2):188-95. PubMed ID: 17543606
[TBL] [Abstract][Full Text] [Related]
4. Design and evaluation of an antiparallel coupled resonator for chemical sensor applications.
Abe T; Kato H
Anal Chem; 2007 Sep; 79(17):6804-6. PubMed ID: 17665878
[TBL] [Abstract][Full Text] [Related]
5. Monitoring cell adhesion processes on bioactive polymers with the quartz crystal resonator technique.
Le Guillou-Buffello D; Hélary G; Gindre M; Pavon-Djavid G; Laugier P; Migonney V
Biomaterials; 2005 Jul; 26(19):4197-205. PubMed ID: 15664647
[TBL] [Abstract][Full Text] [Related]
6. Selective histamine piezoelectric chemosensor using a recognition film of the molecularly imprinted polymer of bis(bithiophene) derivatives.
Pietrzyk A; Suriyanarayanan S; Kutner W; Chitta R; D'Souza F
Anal Chem; 2009 Apr; 81(7):2633-43. PubMed ID: 19278237
[TBL] [Abstract][Full Text] [Related]
7. Effects of electromagnetic radiation on the Q of quartz resonators.
Yong YK; Patel M; Vig J; Ballato A
IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Feb; 56(2):353-60. PubMed ID: 19251522
[TBL] [Abstract][Full Text] [Related]
8. Theory and experimental verifications of the resonator Q and equivalent electrical parameters due to viscoelastic and mounting supports losses.
Yong YK; Patel MS; Tanaka M
IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Aug; 57(8):1831-9. PubMed ID: 20679012
[TBL] [Abstract][Full Text] [Related]
9. Viscosity sensor utilizing a piezoelectric thickness shear sandwich resonator.
Thalhammer R; Braun S; Devcic-Kuhar B; Groschl M; Trampler F; Benes E; Nowotny H; Kostal P
IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(5):1331-40. PubMed ID: 18244295
[TBL] [Abstract][Full Text] [Related]
10. On the accuracy of Mindlin plate predictions for the frequency-temperature behavior of resonant modes in AT- and SC-cut quartz plates.
Yong YK; Wang J; Imai T
IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(1):1-13. PubMed ID: 18238393
[TBL] [Abstract][Full Text] [Related]
11. Mass effects of quartz resonant sensors with different surface microstructures in liquids.
Zhang C; Schranz S; Lucklum R; Hauptmann P
IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(5):1204-10. PubMed ID: 18244280
[TBL] [Abstract][Full Text] [Related]
12. Resonant frequency function of thickness-shear vibrations of rectangular crystal plates.
Wang J; Yang L; Pan Q; Chao MC; Du J
IEEE Trans Ultrason Ferroelectr Freq Control; 2011 May; 58(5):1102-7. PubMed ID: 21622066
[TBL] [Abstract][Full Text] [Related]
13. Experimental study on the characteristic of the NS-GT cut quartz crystal resonator oscillating in the sub-resonant frequency.
Yamagata S; Kawashima H
IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(5):1175-82. PubMed ID: 18244311
[TBL] [Abstract][Full Text] [Related]
14. A lateral-field-excited LiTaO3 high-frequency bulk acoustic wave sensor.
McCann DF; McGann JM; Parks JM; Frankel DJ; da Cunha MP; Vetelino JF
IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Apr; 56(4):779-87. PubMed ID: 19406706
[TBL] [Abstract][Full Text] [Related]
15. Nonlinear coupling between thickness- shear and thickness-stretch modes in a rotated Y-cut quartz resonator.
Yang Z; Hu Y; Wang J; Yang J
IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Jan; 56(1):220-4. PubMed ID: 19213649
[TBL] [Abstract][Full Text] [Related]
16. Real-Time Monitoring of Platelet Activation Using Quartz Thickness-Shear Mode Resonator Sensors.
Wu H; Zhao G; Zu H; Wang JH; Wang QM
Biophys J; 2016 Feb; 110(3):669-679. PubMed ID: 26840731
[TBL] [Abstract][Full Text] [Related]
17. Analytical study of dual-mode thin film bulk acoustic resonators (FBARs) based on ZnO and AlN films with tilted c-axis orientation.
Qin L; Chen Q; Cheng H; Wang QM
IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Aug; 57(8):1840-53. PubMed ID: 20679013
[TBL] [Abstract][Full Text] [Related]
18. Single-scan measurement of conductance of a quartz crystal microbalance array coupled with resonant markers for biosensing in liquid phase.
Hsiao HY; Chen RL; Cheng TJ
Rev Sci Instrum; 2009 Apr; 80(4):044301. PubMed ID: 19405677
[TBL] [Abstract][Full Text] [Related]
19. Laser ultrasonic analysis of normal modes generated by a voltage pulse on an AT quartz sensor.
Goossens J; Martinez L; Glorieux C; Wilkie-Chancellier N; Ehssein CO; Serfaty S
Ultrasonics; 2006 Dec; 44 Suppl 1():e1179-82. PubMed ID: 16797645
[TBL] [Abstract][Full Text] [Related]
20. Isolated electrodeless high-frequency quartz crystal microbalance for immunosensors.
Ogi H; Motoshisa K; Matsumoto T; Hatanaka K; Hirao M
Anal Chem; 2006 Oct; 78(19):6903-9. PubMed ID: 17007513
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]