These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 19813423)

  • 1. Measurement of clinicians' ability to hand torque dental implant components.
    Kanawati A; Richards MW; Becker JJ; Monaco NE
    J Oral Implantol; 2009; 35(4):185-8. PubMed ID: 19813423
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Torque generated by handheld screwdrivers and mechanical torquing devices for osseointegrated implants.
    Goheen KL; Vermilyea SG; Vossoughi J; Agar JR
    Int J Oral Maxillofac Implants; 1994; 9(2):149-55. PubMed ID: 8206549
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implant abutment screw torque generated by general dentists using a hand driver in a limited access space simulating the mouth.
    Hill EE; Phillips SM; Breeding LC
    J Oral Implantol; 2007; 33(5):277-9. PubMed ID: 17987859
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Operator-induced compressive axial forces during implant gold screw fastening.
    Pesun IJ; Brosky ME; Korioth TW; Hodges J; Devoe BJ
    J Prosthet Dent; 2001 Jul; 86(1):15-9. PubMed ID: 11458259
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
    Tan BF; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of torque measurements and clinical handling of various surgical motors.
    Neugebauer J; Scheer M; Mischkowski RA; An SH; Karapetian VE; Toutenburg H; Zoeller JE
    Int J Oral Maxillofac Implants; 2009; 24(3):469-76. PubMed ID: 19587869
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reverse torque failure of screw-shaped implants in baboons: baseline data for abutment torque application.
    Carr AB; Larsen PE; Papazoglou E; McGlumphy E
    Int J Oral Maxillofac Implants; 1995; 10(2):167-74. PubMed ID: 7744435
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparative analysis of deformation of two implant/abutment connection systems during implant insertion. An in vitro study.
    Bambini F; Memè L; Pellecchia M; Sabatucci A; Selvaggio R
    Minerva Stomatol; 2005 Mar; 54(3):129-38. PubMed ID: 15920445
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of electronic implant torque controllers following time in clinical service.
    Mitrani R; Nicholls JI; Phillips KM; Ma T
    Int J Oral Maxillofac Implants; 2001; 16(3):394-9. PubMed ID: 11432659
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Critical bending moment of four implant-abutment interface designs.
    Lee FK; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2010; 25(4):744-51. PubMed ID: 20657869
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of mechanical torque devices for implants used in Brazilian dental offices.
    Santos GC; Passos SP; Coelho Santos MJ
    Int J Prosthodont; 2011; 24(1):38-9. PubMed ID: 21210000
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Initial torque stability of a new bone condensing dental implant. A cohort study of 140 consecutively placed implants.
    Irinakis T; Wiebe C
    J Oral Implantol; 2009; 35(6):277-82. PubMed ID: 20017643
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque.
    Dailey B; Jordan L; Blind O; Tavernier B
    Int J Oral Maxillofac Implants; 2009; 24(2):251-6. PubMed ID: 19492640
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
    Turkyilmaz I; Sennerby L; Yilmaz B; Bilecenoglu B; Ozbek EN
    Clin Implant Dent Relat Res; 2009 Mar; 11(1):52-8. PubMed ID: 18384400
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The dynamic natures of implant loading.
    Wang RF; Kang B; Lang LA; Razzoog ME
    J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Removal torque of immediately loaded transitional endosseous implants in human subjects.
    Simon H; Caputo AA
    Int J Oral Maxillofac Implants; 2002; 17(6):839-45. PubMed ID: 12507244
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bone response to unloaded titanium implants in the fibula, iliac crest, and scapula: an animal study in the Yorkshire pig.
    Rohner D; Meng CS; Hutmacher DW; Tsai KT
    Int J Oral Maxillofac Surg; 2003 Aug; 32(4):383-9. PubMed ID: 14505621
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stress levels for well-fitting implant superstructures as a function of tightening force levels, tightening sequence, and different operators.
    Nissan J; Gross M; Shifman A; Assif D
    J Prosthet Dent; 2001 Jul; 86(1):20-3. PubMed ID: 11458260
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implant abutment screw rotations and preloads for four different screw materials and surfaces.
    Martin WC; Woody RD; Miller BH; Miller AW
    J Prosthet Dent; 2001 Jul; 86(1):24-32. PubMed ID: 11458261
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.
    Kim SG; Park JU; Jeong JH; Bae C; Bae TS; Chee W
    Int J Oral Maxillofac Implants; 2009; 24(6):1061-7. PubMed ID: 20162110
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.