BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

467 related articles for article (PubMed ID: 19813592)

  • 1. [A hybrid reconstruction method in electrical impedance tomography based on GMRES and Tikhonov regularization].
    Wang H; Fan W; Hu L
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Aug; 26(4):701-5. PubMed ID: 19813592
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Image reconstruction in electrical impedance tomography based on genetic algorithm].
    Hou W; Mo Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Mar; 20(1):107-10. PubMed ID: 12744177
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Regularized reconstruction in electrical impedance tomography using a variance uniformization constraint.
    Cohen-Bacrie C; Goussard Y; Guardo R
    IEEE Trans Med Imaging; 1997 Oct; 16(5):562-71. PubMed ID: 9368111
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The selection of Tikhonov regularization parameter in dynamic electrical impedance imaging].
    Peng Y; Mo Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Dec; 20(4):571-3. PubMed ID: 14716847
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Image reconstruction based on L1 regularization and projection methods for electrical impedance tomography.
    Wang Q; Wang H; Zhang R; Wang J; Zheng Y; Cui Z; Yang C
    Rev Sci Instrum; 2012 Oct; 83(10):104707. PubMed ID: 23126790
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging.
    Woo EJ; Seo JK
    Physiol Meas; 2008 Oct; 29(10):R1-26. PubMed ID: 18799834
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel combined regularization algorithm of total variation and Tikhonov regularization for open electrical impedance tomography.
    Liu J; Ling L; Li G
    Physiol Meas; 2013 Jul; 34(7):823-38. PubMed ID: 23787806
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Temporal image reconstruction in electrical impedance tomography.
    Adler A; Dai T; Lionheart WR
    Physiol Meas; 2007 Jul; 28(7):S1-11. PubMed ID: 17664627
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method.
    Bagshaw AP; Liston AD; Bayford RH; Tizzard A; Gibson AP; Tidswell AT; Sparkes MK; Dehghani H; Binnie CD; Holder DS
    Neuroimage; 2003 Oct; 20(2):752-64. PubMed ID: 14568449
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A novel approach for EIT regularization via spatial and spectral principal component analysis.
    Goharian M; Bruwer MJ; Jegatheesan A; Moran GR; MacGregor JF
    Physiol Meas; 2007 Sep; 28(9):1001-16. PubMed ID: 17827649
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accounting for hardware imperfections in EIT image reconstruction algorithms.
    Hartinger AE; Gagnon H; Guardo R
    Physiol Meas; 2007 Jul; 28(7):S13-27. PubMed ID: 17664631
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Variation regularization algorithm in electrical impedance tomography].
    Huang S; He W
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Dec; 23(6):1153-6. PubMed ID: 17228698
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An oppositional biogeography-based optimization technique to reconstruct organ boundaries in the human thorax using electrical impedance tomography.
    Rashid A; Kim BS; Khambampati AK; Kim S; Kim KY
    Physiol Meas; 2011 Jul; 32(7):767-96. PubMed ID: 21646708
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Image reconstruction using interval simulated annealing in electrical impedance tomography.
    Martins Tde C; de Camargo ED; Lima RG; Amato MB; Tsuzuki Mde S
    IEEE Trans Biomed Eng; 2012 Jul; 59(7):1861-70. PubMed ID: 22361655
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The boundary element method in the forward and inverse problem of electrical impedance tomography.
    de Munck JC; Faes TJ; Heethaar RM
    IEEE Trans Biomed Eng; 2000 Jun; 47(6):792-800. PubMed ID: 10833854
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vivo impedance imaging with total variation regularization.
    Borsic A; Graham BM; Adler A; Lionheart WR
    IEEE Trans Med Imaging; 2010 Jan; 29(1):44-54. PubMed ID: 20051330
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Kalman filter approach to track fast impedance changes in electrical impedance tomography.
    Vauhkonen M; Karjalainen PA; Kaipio JP
    IEEE Trans Biomed Eng; 1998 Apr; 45(4):486-93. PubMed ID: 9556965
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [An improved back-projection algorithm of dynamic electrical impedance tomography].
    Xu G; He W; Singer H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Oct; 21(5):761-5. PubMed ID: 15553853
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stable reconstruction of piecewise continuous plane stratified biological tissues via electrical impedance tomography.
    Dolgin M; Einziger PD
    IEEE Trans Biomed Eng; 2010 May; 57(5):1227-33. PubMed ID: 20142149
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tikhonov regularization and prior information in electrical impedance tomography.
    Vauhkonen M; Vadász D; Karjalainen PA; Somersalo E; Kaipio JP
    IEEE Trans Med Imaging; 1998 Apr; 17(2):285-93. PubMed ID: 9688160
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 24.