BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

391 related articles for article (PubMed ID: 19820267)

  • 1. The timing resolution of scintillation-detector systems: Monte Carlo analysis.
    Choong WS
    Phys Med Biol; 2009 Nov; 54(21):6495-513. PubMed ID: 19820267
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analytical calculation of the lower bound on timing resolution for PET scintillation detectors comprising high-aspect-ratio crystal elements.
    Cates JW; Vinke R; Levin CS
    Phys Med Biol; 2015 Jul; 60(13):5141-61. PubMed ID: 26083559
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A new timing model for calculating the intrinsic timing resolution of a scintillator detector.
    Shao Y
    Phys Med Biol; 2007 Feb; 52(4):1103-17. PubMed ID: 17264373
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging.
    Nillius P; Klamra W; Sibczynski P; Sharma D; Danielsson M; Badano A
    Med Phys; 2015 Feb; 42(2):600-605. PubMed ID: 28102604
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
    Habte F; Foudray AM; Olcott PD; Levin CS
    Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte Carlo calculations of PET coincidence timing: single and double-ended readout.
    Derenzo SE; Choong WS; Moses WW
    Phys Med Biol; 2015 Sep; 60(18):7309-38. PubMed ID: 26350162
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of stacked-crystal PET detector designs for measurement of both TOF and DOI.
    Schmall JP; Surti S; Karp JS
    Phys Med Biol; 2015 May; 60(9):3549-65. PubMed ID: 25860172
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An edge-readout, multilayer detector for positron emission tomography.
    Li X; Ruiz-Gonzalez M; Furenlid LR
    Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optical simulation of monolithic scintillator detectors using GATE/GEANT4.
    van der Laan DJJ; Schaart DR; Maas MC; Beekman FJ; Bruyndonckx P; van Eijk CWE
    Phys Med Biol; 2010 Mar; 55(6):1659-75. PubMed ID: 20182005
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A layered single-side readout depth of interaction time-of-flight-PET detector.
    Bläckberg L; Sajedi S; El Fakhri G; Sabet H
    Phys Med Biol; 2021 Feb; 66(4):045025. PubMed ID: 33570050
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The lower timing resolution bound for scintillators with non-negligible optical photon transport time in time-of-flight PET.
    Vinke R; Olcott PD; Cates JW; Levin CS
    Phys Med Biol; 2014 Oct; 59(20):6215-29. PubMed ID: 25255807
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analytical model of coincidence resolving time in TOF-PET.
    Wieczorek H; Thon A; Dey T; Khanin V; Rodnyi P
    Phys Med Biol; 2016 Jun; 61(12):4699-710. PubMed ID: 27245232
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of intrinsic rise times for various L(Y)SO and LuAG scintillators with a general study of prompt photons to achieve 10 ps in TOF-PET.
    Gundacker S; Auffray E; Pauwels K; Lecoq P
    Phys Med Biol; 2016 Apr; 61(7):2802-37. PubMed ID: 26982798
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo Simulation Study on the Time Resolution of a PMT-Quadrant-Sharing LSO Detector Block for Time-of-Flight PET.
    Liu S; Li H; Zhang Y; Ramirez RA; Baghaei H; An S; Wang C; Liu J; Wong WH
    IEEE Trans Nucl Sci; 2009; 56(5):2614-2620. PubMed ID: 20559457
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigating the temporal resolution limits of scintillation detection from pixellated elements: comparison between experiment and simulation.
    Spanoudaki VCh; Levin CS
    Phys Med Biol; 2011 Feb; 56(3):735-56. PubMed ID: 21239845
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo simulations of time-of-flight PET with double-ended readout: calibration, coincidence resolving times and statistical lower bounds.
    Derenzo SE
    Phys Med Biol; 2017 May; 62(9):3828-3858. PubMed ID: 28327464
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Towards a metamaterial approach for fast timing in PET: experimental proof-of-concept.
    Turtos RM; Gundacker S; Auffray E; Lecoq P
    Phys Med Biol; 2019 Sep; 64(18):185018. PubMed ID: 30978716
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout.
    Son JW; Lee MS; Lee JS
    Phys Med Biol; 2017 Jan; 62(2):465-483. PubMed ID: 28000613
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance of long rectangular semi-monolithic scintillator PET detectors.
    Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pushing the limit of BGO-based dual-ended Cherenkov PET detectors through photon transit time correction.
    Yi M; Ko GB; Lee JS
    Phys Med Biol; 2024 Jan; 69(2):. PubMed ID: 38091614
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 20.