445 related articles for article (PubMed ID: 19840654)
1. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments.
Alapati SB; Brantley WA; Iijima M; Clark WA; Kovarik L; Buie C; Liu J; Ben Johnson W
J Endod; 2009 Nov; 35(11):1589-93. PubMed ID: 19840654
[TBL] [Abstract][Full Text] [Related]
2. Metallurgical characterization of M-Wire nickel-titanium shape memory alloy used for endodontic rotary instruments during low-cycle fatigue.
Ye J; Gao Y
J Endod; 2012 Jan; 38(1):105-7. PubMed ID: 22152631
[TBL] [Abstract][Full Text] [Related]
3. Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments.
Shen Y; Zhou HM; Zheng YF; Campbell L; Peng B; Haapasalo M
J Endod; 2011 Nov; 37(11):1566-71. PubMed ID: 22000465
[TBL] [Abstract][Full Text] [Related]
4. Mechanical properties of controlled memory and superelastic nickel-titanium wires used in the manufacture of rotary endodontic instruments.
Zhou HM; Shen Y; Zheng W; Li L; Zheng YF; Haapasalo M
J Endod; 2012 Nov; 38(11):1535-40. PubMed ID: 23063231
[TBL] [Abstract][Full Text] [Related]
5. Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel-titanium wires employed in the manufacture of rotary endodontic instruments.
Bahia MG; Martins RC; Gonzalez BM; Buono VT
Int Endod J; 2005 Nov; 38(11):795-801. PubMed ID: 16218971
[TBL] [Abstract][Full Text] [Related]
6. Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use.
Brantley WA; Svec TA; Iijima M; Powers JM; Grentzer TH
J Endod; 2002 Nov; 28(11):774-8. PubMed ID: 12470023
[TBL] [Abstract][Full Text] [Related]
7. Impact of heat treatments on the fatigue resistance of different rotary nickel-titanium instruments.
Braga LC; Faria Silva AC; Buono VT; de Azevedo Bahia MG
J Endod; 2014 Sep; 40(9):1494-7. PubMed ID: 25146041
[TBL] [Abstract][Full Text] [Related]
8. Improvement of the fatigue resistance of NiTi endodontic files by surface and bulk modifications.
Condorelli GG; Bonaccorso A; Smecca E; Schäfer E; Cantatore G; Tripi TR
Int Endod J; 2010 Oct; 43(10):866-73. PubMed ID: 20618880
[TBL] [Abstract][Full Text] [Related]
9. Micro-XRD and temperature-modulated DSC investigation of nickel-titanium rotary endodontic instruments.
Alapati SB; Brantley WA; Iijima M; Schricker SR; Nusstein JM; Li UM; Svec TA
Dent Mater; 2009 Oct; 25(10):1221-9. PubMed ID: 19524288
[TBL] [Abstract][Full Text] [Related]
10. Defects in nickel-titanium instruments after clinical use. Part 5: single use from endodontic specialty practices.
Shen Y; Coil JM; McLean AG; Hemerling DL; Haapasalo M
J Endod; 2009 Oct; 35(10):1363-7. PubMed ID: 19801231
[TBL] [Abstract][Full Text] [Related]
11. Physical and mechanical properties of a thermomechanically treated NiTi wire used in the manufacture of rotary endodontic instruments.
Pereira ES; Peixoto IF; Viana AC; Oliveira II; Gonzalez BM; Buono VT; Bahia MG
Int Endod J; 2012 May; 45(5):469-74. PubMed ID: 22188417
[TBL] [Abstract][Full Text] [Related]
12. HyFlex nickel-titanium rotary instruments after clinical use: metallurgical properties.
Shen Y; Coil JM; Zhou H; Zheng Y; Haapasalo M
Int Endod J; 2013 Aug; 46(8):720-9. PubMed ID: 23330612
[TBL] [Abstract][Full Text] [Related]
13. Fatigue and mechanical properties of nickel-titanium endodontic instruments.
Kuhn G; Jordan L
J Endod; 2002 Oct; 28(10):716-20. PubMed ID: 12398171
[TBL] [Abstract][Full Text] [Related]
14. Effects of raw material and rotational speed on the cyclic fatigue of ProFile Vortex rotary instruments.
Gao Y; Shotton V; Wilkinson K; Phillips G; Johnson WB
J Endod; 2010 Jul; 36(7):1205-9. PubMed ID: 20630300
[TBL] [Abstract][Full Text] [Related]
15. The NiTi superelastic alloy application to the dentistry field.
Torrisi L
Biomed Mater Eng; 1999; 9(1):39-47. PubMed ID: 10436852
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments.
Gao Y; Gutmann JL; Wilkinson K; Maxwell R; Ammon D
J Endod; 2012 Mar; 38(3):398-401. PubMed ID: 22341083
[TBL] [Abstract][Full Text] [Related]
17. SEM observations and differential scanning calorimetric studies of new and sterilized nickel-titanium rotary endodontic instruments.
Alexandrou GB; Chrissafis K; Vasiliadis LP; Pavlidou E; Polychroniadis EK
J Endod; 2006 Jul; 32(7):675-9. PubMed ID: 16793479
[TBL] [Abstract][Full Text] [Related]
18. Effect of heat treatment on transformation temperatures and bending properties of nickel-titanium endodontic instruments.
Yahata Y; Yoneyama T; Hayashi Y; Ebihara A; Doi H; Hanawa T; Suda H
Int Endod J; 2009 Jul; 42(7):621-6. PubMed ID: 19467049
[TBL] [Abstract][Full Text] [Related]
19. Microstructural studies of 35 degrees C copper Ni-Ti orthodontic wire and TEM confirmation of low-temperature martensite transformation.
Brantley WA; Guo W; Clark WA; Iijima M
Dent Mater; 2008 Feb; 24(2):204-10. PubMed ID: 17561249
[TBL] [Abstract][Full Text] [Related]
20. Torsional strength and toughness of nickel-titanium rotary files.
Yum J; Cheung GS; Park JK; Hur B; Kim HC
J Endod; 2011 Mar; 37(3):382-6. PubMed ID: 21329826
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]