These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 19852651)

  • 21. Factors affecting the long-term stability of orthodontic mini-implants.
    Motoyoshi M; Uemura M; Ono A; Okazaki K; Shigeeda T; Shimizu N
    Am J Orthod Dentofacial Orthop; 2010 May; 137(5):588.e1-5; discussion 588-9. PubMed ID: 20451776
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Cone-beam computed tomography evaluation of mini-implants after placement: Is root proximity a major risk factor for failure?
    Kim SH; Kang SM; Choi YS; Kook YA; Chung KR; Huang JC
    Am J Orthod Dentofacial Orthop; 2010 Sep; 138(3):264-76. PubMed ID: 20816295
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Bone changes around early loaded chemically modified sandblasted and acid-etched surfaced implants with and without a machined collar: a radiographic and resonance frequency analysis in the canine mandible.
    Valderrama P; Jones AA; Wilson TG; Higginbottom F; Schoolfield JD; Jung RE; Noujeim M; Cochran DL
    Int J Oral Maxillofac Implants; 2010; 25(3):548-57. PubMed ID: 20556254
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Orthodontic mini-implant stability in different healing times before loading: a microscopic computerized tomographic and biomechanical analysis.
    Zhao L; Xu Z; Yang Z; Wei X; Tang T; Zhao Z
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Aug; 108(2):196-202. PubMed ID: 19615659
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit.
    Klokkevold PR; Nishimura RD; Adachi M; Caputo A
    Clin Oral Implants Res; 1997 Dec; 8(6):442-7. PubMed ID: 9555202
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of autoclaving on the fracture torque of mini-implants used for orthodontic anchorage.
    Mattos CT; Ruellas AC; Sant'anna EF
    J Orthod; 2011 Mar; 38(1):15-20. PubMed ID: 21367824
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Removal torque and histomorphometric evaluation of bioceramic grit-blasted/acid-etched and dual acid-etched implant surfaces: an experimental study in dogs.
    Marin C; Granato R; Suzuki M; Gil JN; Piattelli A; Coelho PG
    J Periodontol; 2008 Oct; 79(10):1942-9. PubMed ID: 18834250
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Machined versus roughened immediately loaded and finally restored single implants inserted flapless: Preliminary 6-month data from a split- mouth randomised controlled trial.
    Cannizzaro G; Felice P; Loi I; Viola P; Ferri V; Leone M; Lazzarini M; Trullenque-Eriksson A; Esposito M
    Eur J Oral Implantol; 2016; 9 Suppl 1(2):155-63. PubMed ID: 27314121
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Clinical indices for orthodontic mini-implants.
    Motoyoshi M
    J Oral Sci; 2011 Dec; 53(4):407-12. PubMed ID: 22167023
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Long-term follow-up of dental single implants under immediate orthodontic load.
    Palagi LM; Sabrosa CE; Gava EC; Baccetti T; Miguel JA
    Angle Orthod; 2010 Sep; 80(5):807-11. PubMed ID: 20578849
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Histomorphologic and histomophometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage.
    Freire JN; Silva NR; Gil JN; Magini RS; Coelho PG
    Am J Orthod Dentofacial Orthop; 2007 Jun; 131(6):704.e1-9. PubMed ID: 17561041
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of a new titanium-zirconium dental implant: a biomechanical and histological comparative study in the mini pig.
    Gottlow J; Dard M; Kjellson F; Obrecht M; Sennerby L
    Clin Implant Dent Relat Res; 2012 Aug; 14(4):538-45. PubMed ID: 20586785
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Early endosseous integration enhanced by dual acid etching of titanium: a torque removal study in the rabbit.
    Klokkevold PR; Johnson P; Dadgostari S; Caputo A; Davies JE; Nishimura RD
    Clin Oral Implants Res; 2001 Aug; 12(4):350-7. PubMed ID: 11488864
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Osseointegration of zirconia implants with different surface characteristics: an evaluation in rabbits.
    Hoffmann O; Angelov N; Zafiropoulos GG; Andreana S
    Int J Oral Maxillofac Implants; 2012; 27(2):352-8. PubMed ID: 22442775
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A pilot study of the osseointegration potential of a surface-treated mini-implant: bone contact of implants retrieved from patients.
    Seo W; Kim SH; Chung KR; Nelson G
    World J Orthod; 2009; 10(3):202-10. PubMed ID: 19885421
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of the surface characteristics of anodic oxidized miniscrews and their impact on biomechanical stability: An experimental study in beagle dogs.
    Choi SH; Jang SH; Cha JY; Hwang CJ
    Am J Orthod Dentofacial Orthop; 2016 Jan; 149(1):31-8. PubMed ID: 26718375
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants.
    Motoyoshi M; Yoshida T; Ono A; Shimizu N
    Int J Oral Maxillofac Implants; 2007; 22(5):779-84. PubMed ID: 17974113
    [TBL] [Abstract][Full Text] [Related]  

  • 38. An experimental comparison of two different clinically used implant designs and surfaces.
    Gottlow J; Barkarmo S; Sennerby L
    Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e204-12. PubMed ID: 22487460
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of the Stability of Sandblasted, Large-Grit, and Acid-Etched Treated Mini-Screws With Two Different Surface Roughness Values: A Histomorphometric Study.
    Seker ED; Yavuz I; Yucesoy T; Cenkci E; Yay A
    J Craniofac Surg; 2022 Jan-Feb 01; 33(1):41-47. PubMed ID: 34267129
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis.
    Kang HK; Chu TM; Dechow P; Stewart K; Kyung HM; Liu SS
    Eur J Orthod; 2016 Apr; 38(2):154-62. PubMed ID: 25908868
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.