267 related articles for article (PubMed ID: 19854658)
1. A laparoscopic knot-tying device for minimally invasive cardiac surgery.
Jernigan SR; Chanoit G; Veeramani A; Owen SB; Hilliard M; Cormier D; Laffitte B; Buckner G
Eur J Cardiothorac Surg; 2010 Mar; 37(3):626-30. PubMed ID: 19854658
[TBL] [Abstract][Full Text] [Related]
2. A Novel Shape-Memory Monofilament Suture for Minimally Invasive Thoracoscopic Cardiac Surgery.
Seguchi R; Ishikawa N; Tarui T; Horikawa T; Ushijima T; Watanabe G
Innovations (Phila); 2019 Feb; 14(1):55-59. PubMed ID: 30848715
[TBL] [Abstract][Full Text] [Related]
3. Arthroscopic knots: determining the optimal balance of loop security and knot security.
Lo IK; Burkhart SS; Chan KC; Athanasiou K
Arthroscopy; 2004 May; 20(5):489-502. PubMed ID: 15122139
[TBL] [Abstract][Full Text] [Related]
4. An ex-vivo evaluation of the application and strength of a novel laparoscopic knot substitute device.
Chi T; Eisner BH; Berger AD; Stoller ML
J Endourol; 2010 Jan; 24(1):95-8. PubMed ID: 19929424
[TBL] [Abstract][Full Text] [Related]
5. Comparison of strength, consistency, and speed of COR-KNOT versus manually hand-tied knots in an ex vivo minimally invasive model.
Lee CY; Sauer JS; Gorea HR; Martellaro AJ; Knight PA
Innovations (Phila); 2014; 9(2):111-6; discussion 116. PubMed ID: 24755535
[TBL] [Abstract][Full Text] [Related]
6. Comparison and analysis of laparoscopic intracorporeal suturing devices: preliminary results.
Pattaras JG; Smith GS; Landman J; Moore RG
J Endourol; 2001 Mar; 15(2):187-92. PubMed ID: 11325091
[TBL] [Abstract][Full Text] [Related]
7. How reliable is intracorporeal laparoscopic knot tying?
Lopez PJ; Veness J; Wojcik A; Curry J
J Laparoendosc Adv Surg Tech A; 2006 Aug; 16(4):428-32. PubMed ID: 16968200
[TBL] [Abstract][Full Text] [Related]
8. Knot integrity using different suture types and different knot-tying techniques for reconstructive pelvic floor procedures.
DueƱas-Garcia OF; Sullivan GM; Leung K; Billiar KL; Flynn MK
Int Urogynecol J; 2018 Jul; 29(7):979-985. PubMed ID: 28634623
[TBL] [Abstract][Full Text] [Related]
9. Performance Comparison of a Pretied Suture Knot With Three Conventional Arthroscopic Knots.
Rodes SA; Favorito PJ; Piccirillo JM; Spivey JT
Arthroscopy; 2015 Nov; 31(11):2183-90. PubMed ID: 26188782
[TBL] [Abstract][Full Text] [Related]
10. Laparoscopic intracorporeal knot tying using a novel device.
Tu FC; Wu WY; Lin HH; Hsiao SM
Surg Endosc; 2012 Mar; 26(3):872-6. PubMed ID: 21993945
[TBL] [Abstract][Full Text] [Related]
11. Differences of tensile strength in knot tying technique between orthopaedic surgical instructors and trainees.
Harato K; Yagi M; Kaneda K; Iwama Y; Masuda A; Kaneko Y; Oya A; Matsumura N; Suzuki T; Nakayama R; Kobayashi S
BMC Surg; 2021 Feb; 21(1):75. PubMed ID: 33549063
[TBL] [Abstract][Full Text] [Related]
12. A comparison of the strength of knots tied by hand and at laparoscopy.
Kadirkamanathan SS; Shelton JC; Hepworth CC; Laufer JG; Swain CP
J Am Coll Surg; 1996 Jan; 182(1):46-54. PubMed ID: 8542089
[TBL] [Abstract][Full Text] [Related]
13. Tying modified clinch knots during single-incision laparoscopic surgery.
Fujioka S; Misawa T; Kitamura H; Kumagai Y; Akiba T; Yanaga K
Asian J Endosc Surg; 2018 Feb; 11(1):79-82. PubMed ID: 29485250
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of a novel modified suture material designed to facilitate intracorporeal knot tying during laparoscopic surgery.
Tan A; Razvi H
J Endourol; 2005 Nov; 19(9):1104-8. PubMed ID: 16283848
[TBL] [Abstract][Full Text] [Related]
15. A Biomechanical Comparison of Different Knots Tied on Fibrewire Suture.
Jiang J; Mat Jais IS; Yam AK; McGrouther DA; Tay SC
J Hand Surg Asian Pac Vol; 2017 Mar; 22(1):65-69. PubMed ID: 28205484
[TBL] [Abstract][Full Text] [Related]
16. Knot Security- How is it Affected by Suture Technique, Material, Size, and Number of Throws?
Silver E; Wu R; Grady J; Song L
J Oral Maxillofac Surg; 2016 Jul; 74(7):1304-12. PubMed ID: 26979258
[TBL] [Abstract][Full Text] [Related]
17. A Biomechanical Comparison of Varying Base Knot Configurations with Different Overhand/Underhand Combinations of Reversing Half-Hitches on Alternating Posts After Basic Instructional Training.
Evin HA; Bilden TT; Noonan BC; Chong AC
Iowa Orthop J; 2019; 39(1):131-140. PubMed ID: 31413686
[TBL] [Abstract][Full Text] [Related]
18. Optimizing Laparoscopically Extracorporeal Knot Tying Using a Novel Pusher Device.
Tu FC; Sun HD; Ting WH; Wu WY; Lin HH; Hsiao SM
Surg Laparosc Endosc Percutan Tech; 2017 Jun; 27(3):e31-e35. PubMed ID: 28399061
[TBL] [Abstract][Full Text] [Related]
19. Tying a loop-to-strand suture: is it safe?
Hurt J; Unger JB; Ivy JJ; Mukherjee D; Pizzaro A
Am J Obstet Gynecol; 2005 Apr; 192(4):1094-7. PubMed ID: 15846186
[TBL] [Abstract][Full Text] [Related]
20. Operating room fatigue: is your twentieth surgical knot as strong as your first?
Muffly TM; Espaillat-Rijo LM; Edwards AM; Horton A
J Surg Educ; 2012; 69(2):215-7. PubMed ID: 22365868
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]