BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 19855293)

  • 1. Mild learning effect of short-wavelength automated perimetry using SITA program.
    Fogagnolo P; Tanga L; Rossetti L; Oddone F; Manni G; Orzalesi N; Centofanti M
    J Glaucoma; 2010; 19(5):319-23. PubMed ID: 19855293
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Diagnostic sensitivity of fast blue-yellow and standard automated perimetry in early glaucoma: a comparison between different test programs.
    Bengtsson B; Heijl A
    Ophthalmology; 2006 Jul; 113(7):1092-7. PubMed ID: 16815399
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Learning effect of short-wavelength automated perimetry in patients with ocular hypertension.
    Rossetti L; Fogagnolo P; Miglior S; Centofanti M; Vetrugno M; Orzalesi N
    J Glaucoma; 2006 Oct; 15(5):399-404. PubMed ID: 16988602
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Learning effect of humphrey matrix frequency doubling technology perimetry in patients with ocular hypertension.
    Centofanti M; Fogagnolo P; Oddone F; Orzalesi N; Vetrugno M; Manni G; Rossetti L
    J Glaucoma; 2008 Sep; 17(6):436-41. PubMed ID: 18794676
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evidence for a learning effect in short-wavelength automated perimetry.
    Wild JM; Kim LS; Pacey IE; Cunliffe IA
    Ophthalmology; 2006 Feb; 113(2):206-15. PubMed ID: 16458091
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A comparative analysis of standard automated perimetry and short wavelength automated perimetry in early diagnosis of glaucoma].
    Chiseliţă D; Crenguţa MI; Danielescu C; Mihaela NM
    Oftalmologia; 2006; 50(2):94-102. PubMed ID: 16927766
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma.
    Artes PH; Hutchison DM; Nicolela MT; LeBlanc RP; Chauhan BC
    Invest Ophthalmol Vis Sci; 2005 Jul; 46(7):2451-7. PubMed ID: 15980235
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Properties of perimetric threshold estimates from Full Threshold, SITA Standard, and SITA Fast strategies.
    Artes PH; Iwase A; Ohno Y; Kitazawa Y; Chauhan BC
    Invest Ophthalmol Vis Sci; 2002 Aug; 43(8):2654-9. PubMed ID: 12147599
    [TBL] [Abstract][Full Text] [Related]  

  • 9. SITA standard in optic neuropathies and hemianopias: a comparison with full threshold testing.
    Wall M; Punke SG; Stickney TL; Brito CF; Withrow KR; Kardon RH
    Invest Ophthalmol Vis Sci; 2001 Feb; 42(2):528-37. PubMed ID: 11157893
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparing multifocal VEP and standard automated perimetry in high-risk ocular hypertension and early glaucoma.
    Fortune B; Demirel S; Zhang X; Hood DC; Patterson E; Jamil A; Mansberger SL; Cioffi GA; Johnson CA
    Invest Ophthalmol Vis Sci; 2007 Mar; 48(3):1173-80. PubMed ID: 17325161
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Between-algorithm, between-individual differences in normal perimetric sensitivity: full threshold, FASTPAC, and SITA. Swedish Interactive Threshold algorithm.
    Wild JM; Pacey IE; Hancock SA; Cunliffe IA
    Invest Ophthalmol Vis Sci; 1999 May; 40(6):1152-61. PubMed ID: 10235548
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Frequency doubling perimetry and short-wavelength automated perimetry to detect early glaucoma.
    Leeprechanon N; Giaconi JA; Manassakorn A; Hoffman D; Caprioli J
    Ophthalmology; 2007 May; 114(5):931-7. PubMed ID: 17397926
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The SITA perimetric threshold algorithms in glaucoma.
    Wild JM; Pacey IE; O'Neill EC; Cunliffe IA
    Invest Ophthalmol Vis Sci; 1999 Aug; 40(9):1998-2009. PubMed ID: 10440254
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.
    Sample PA; Bosworth CF; Blumenthal EZ; Girkin C; Weinreb RN
    Invest Ophthalmol Vis Sci; 2000 Jun; 41(7):1783-90. PubMed ID: 10845599
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relationship between Humphrey 30-2 SITA Standard Test, Matrix 30-2 threshold test, and Heidelberg retina tomograph in ocular hypertensive and glaucoma patients.
    Bozkurt B; Yilmaz PT; Irkec M
    J Glaucoma; 2008; 17(3):203-10. PubMed ID: 18414106
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Evaluation of the Humphrey perimetry programs SITA Standard and SITA Fast in normal probands and patients with glaucoma].
    Nordmann JP; Brion F; Hamard P; Mouton-Chopin D
    J Fr Ophtalmol; 1998 Oct; 21(8):549-54. PubMed ID: 9833219
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The ability of short-wavelength automated perimetry to predict conversion to glaucoma.
    van der Schoot J; Reus NJ; Colen TP; Lemij HG
    Ophthalmology; 2010 Jan; 117(1):30-4. PubMed ID: 19896194
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Frequency-doubling perimetry: comparison with standard automated perimetry to detect glaucoma.
    Leeprechanon N; Giangiacomo A; Fontana H; Hoffman D; Caprioli J
    Am J Ophthalmol; 2007 Feb; 143(2):263-271. PubMed ID: 17178091
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Repeatability of the Glaucoma Hemifield Test in automated perimetry.
    Katz J; Quigley HA; Sommer A
    Invest Ophthalmol Vis Sci; 1995 Jul; 36(8):1658-64. PubMed ID: 7601645
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Can frequency-doubling technology and short-wavelength automated perimetries detect visual field defects before standard automated perimetry in patients with preperimetric glaucoma?
    Ferreras A; Polo V; Larrosa JM; Pablo LE; Pajarin AB; Pueyo V; Honrubia FM
    J Glaucoma; 2007; 16(4):372-83. PubMed ID: 17571000
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.