These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 19859644)

  • 1. Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems?
    Fan B; Lu Y; Genant H; Fuerst T; Shepherd J
    Osteoporos Int; 2010 Jul; 21(7):1227-36. PubMed ID: 19859644
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Standardization of spine and hip BMD measurements in different DXA devices.
    Ozdemir A; Uçar M
    Eur J Radiol; 2007 Jun; 62(3):423-6. PubMed ID: 17289322
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Gender disparity in BMD conversion: a comparison between Lunar and Hologic densitometers.
    Ganda K; Nguyen TV; Pocock N
    Arch Osteoporos; 2014; 9():180. PubMed ID: 25527404
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved precision with Hologic Apex software.
    Fan B; Lewiecki EM; Sherman M; Lu Y; Miller PD; Genant HK; Shepherd JA
    Osteoporos Int; 2008 Nov; 19(11):1597-602. PubMed ID: 18373054
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Universal standardization for dual x-ray absorptiometry: patient and phantom cross-calibration results.
    Genant HK; Grampp S; Glüer CC; Faulkner KG; Jergas M; Engelke K; Hagiwara S; Van Kuijk C
    J Bone Miner Res; 1994 Oct; 9(10):1503-14. PubMed ID: 7817795
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A multinational study to develop universal standardization of whole-body bone density and composition using GE Healthcare Lunar and Hologic DXA systems.
    Shepherd JA; Fan B; Lu Y; Wu XP; Wacker WK; Ergun DL; Levine MA
    J Bone Miner Res; 2012 Oct; 27(10):2208-16. PubMed ID: 22623101
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of BMD precision for Prodigy and Delphi spine and femur scans.
    Shepherd JA; Fan B; Lu Y; Lewiecki EM; Miller P; Genant HK
    Osteoporos Int; 2006; 17(9):1303-8. PubMed ID: 16823544
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dual X-ray absorptiometry: clinical evaluation of a new cone-beam system.
    Blake GM; Knapp KM; Fogelman I
    Calcif Tissue Int; 2005 Feb; 76(2):113-20. PubMed ID: 15645160
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vivo precision of the GE lunar iDXA for the assessment of lumbar spine, total hip, femoral neck, and total body bone mineral density in severely obese patients.
    Carver TE; Christou NV; Court O; Lemke H; Andersen RE
    J Clin Densitom; 2014; 17(1):109-15. PubMed ID: 23896494
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cross-Calibration of Prodigy and Horizon A Densitometers and Precision of the Horizon A Densitometer.
    Reitshamer E; Barrett K; Shea K; Dawson-Hughes B
    J Clin Densitom; 2021; 24(3):474-480. PubMed ID: 33744116
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cross-calibration of GE/Lunar pencil and fan-beam dual energy densitometers--bone mineral density and body composition studies.
    Oldroyd B; Smith AH; Truscott JG
    Eur J Clin Nutr; 2003 Aug; 57(8):977-87. PubMed ID: 12879093
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A preliminary evaluation of the lunar expert-XL for bone densitometry and vertebral morphometry.
    Lang T; Takada M; Gee R; Wu C; Li J; Hayashi-Clark C; Schoen S; March V; Genant HK
    J Bone Miner Res; 1997 Jan; 12(1):136-43. PubMed ID: 9240736
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The evaluation of consistency between body composition assessments in pediatric population using pencil beam and fan beam dual-energy x-ray absorptiometers.
    Pludowski P; Jaworski M; Matusik H; Kobylinska M; Klimek P; Lorenc RS
    J Clin Densitom; 2010; 13(1):84-95. PubMed ID: 20171570
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reference values of bone mineral density and prevalence of osteoporosis in Chinese adults.
    Zhang ZQ; Ho SC; Chen ZQ; Zhang CX; Chen YM
    Osteoporos Int; 2014 Feb; 25(2):497-507. PubMed ID: 23800746
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of spine and femur reference data in native Chinese women from different regions of China.
    Wu XP; Liao EY; Dai RC; Shan PF; Fang TY; Luo XH; Pi YZ; Jiang Y
    Osteoporos Int; 2005 Oct; 16(10):1215-24. PubMed ID: 15782285
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dual X-ray absorptiometry: cross-calibration of a new fan-beam system.
    Blake GM; Harrison EJ; Adams JE
    Calcif Tissue Int; 2004 Jul; 75(1):7-14. PubMed ID: 15037973
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Cross-Calibration Study of GE Lunar iDXA and GE Lunar DPX Pro for Body Composition Measurements in Children and Adults.
    Khadilkar A; Chiplonkar S; Sanwalka N; Khadilkar V; Mandlik R; Ekbote V
    J Clin Densitom; 2020; 23(1):128-137. PubMed ID: 30981615
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of the Lunar Prodigy and Stratos DR Dual-Energy X-Ray Absorptiometers to Assess Regional Bone Mineral Density.
    Maïmoun L; Mahadea KK; Boudousq V; Mura T; Mariano-Goulart D
    J Clin Densitom; 2022; 25(4):569-576. PubMed ID: 35909031
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pencil-beam vs fan-beam dual-energy X-ray absorptiometry comparisons across four systems: body composition and bone mineral.
    Soriano JM; Ioannidou E; Wang J; Thornton JC; Horlick MN; Gallagher D; Heymsfield SB; Pierson RN
    J Clin Densitom; 2004; 7(3):281-9. PubMed ID: 15319498
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of phantoms for cross-calibration of lumbar spine DXA.
    Pearson D; Cawte SA; Green DJ
    Osteoporos Int; 2002 Dec; 13(12):948-54. PubMed ID: 12459937
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.