These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

221 related articles for article (PubMed ID: 19861122)

  • 1. Urine sediment analysis: Analytical and diagnostic performance of sediMAX - a new automated microscopy image-based urine sediment analyser.
    Zaman Z; Fogazzi GB; Garigali G; Croci MD; Bayer G; Kránicz T
    Clin Chim Acta; 2010 Feb; 411(3-4):147-54. PubMed ID: 19861122
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analytical performance of the Iris iQ200 automated urine microscopy analyzer.
    Linko S; Kouri TT; Toivonen E; Ranta PH; Chapoulaud E; Lalla M
    Clin Chim Acta; 2006 Oct; 372(1-2):54-64. PubMed ID: 16696963
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of a new automated microscopy urine sediment analyser - sediMAX conTRUST®.
    Bogaert L; Peeters B; Billen J
    Acta Clin Belg; 2017 Apr; 72(2):91-94. PubMed ID: 27796180
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of LabUMat-with-UriSed and iQ200 fully automatic urine sediment analysers with manual urine analysis.
    Akin OK; Serdar MA; Cizmeci Z; Genc O; Aydin S
    Biotechnol Appl Biochem; 2009 Jun; 53(Pt 2):139-44. PubMed ID: 19021504
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analytic performance of the iQ200 automated urine microscopy analyzer and comparison with manual counts using Fuchs-Rosenthal cell chambers.
    Wah DT; Wises PK; Butch AW
    Am J Clin Pathol; 2005 Feb; 123(2):290-6. PubMed ID: 15842056
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Urine analysis performed by flow cytometry: reference range determination and comparison to morphological findings, dipstick chemistry and bacterial culture results--a multicenter study.
    Regeniter A; Haenni V; Risch L; Köchli HP; Colombo JP; Frei R; Huber AR
    Clin Nephrol; 2001 May; 55(5):384-92. PubMed ID: 11393384
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the Sysmex UF-100 automated urinalysis analyzer and comparative study with JCCLS reference method.
    Sutheesophon K; Wiwanitkit V; Boonchalermvichian C; Charuruks N
    J Med Assoc Thai; 2002 Jun; 85 Suppl 1():S246-52. PubMed ID: 12188419
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Urine sediment examination: a comparison of automated urinalysis systems and manual microscopy.
    Chien TI; Kao JT; Liu HL; Lin PC; Hong JS; Hsieh HP; Chien MJ
    Clin Chim Acta; 2007 Sep; 384(1-2):28-34. PubMed ID: 17604012
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical laboratory urine analysis: comparison of the UriSed automated microscopic analyzer and the manual microscopy.
    Ma J; Wang C; Yue J; Li M; Zhang H; Ma X; Li X; Xue D; Qing X; Wang S; Xiang D; Cong Y
    Clin Lab; 2013; 59(11-12):1297-303. PubMed ID: 24409664
    [TBL] [Abstract][Full Text] [Related]  

  • 10. UriSed - Preliminary reference intervals and optimal method for urine sediment analysis in newborns and infants.
    Manda-Handzlik A; Sztefko K; Zając A; Kwinta P; Tomasik P
    Clin Biochem; 2016 Aug; 49(12):909-14. PubMed ID: 27132496
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the diagnostic performance of two automated urine sediment analyzers with manual phase-contrast microscopy.
    Enko D; Stelzer I; Böckl M; Derler B; Schnedl WJ; Anderssohn P; Meinitzer A; Herrmann M
    Clin Chem Lab Med; 2020 Jan; 58(2):268-273. PubMed ID: 31605578
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Urine sediment examination: a comparison between the manual method and the iQ200 automated urine microscopy analyzer.
    Lamchiagdhase P; Preechaborisutkul K; Lomsomboon P; Srisuchart P; Tantiniti P; Khan-u-Ra N; Preechaborisutkul B
    Clin Chim Acta; 2005 Aug; 358(1-2):167-74. PubMed ID: 16018883
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance evaluation of a new and improved cuvette-based automated urinalysis analyzer with phase contrast microscopy.
    Falbo R; Sala MR; Bussetti M; Cappellini F; Giacobone C; Fania C; Brambilla P
    Clin Chim Acta; 2019 Apr; 491():126-131. PubMed ID: 30703345
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of the Automated cobas u 701 Urine Microscopy and UF-1000i Flow Cytometry Systems and Manual Microscopy in the Examination of Urine Sediments.
    Lee W; Ha JS; Ryoo NH
    J Clin Lab Anal; 2016 Sep; 30(5):663-71. PubMed ID: 26842372
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance evaluation of the new fully automated urine particle analyser UF-5000 compared to the reference method of the Fuchs-Rosenthal chamber.
    Previtali G; Ravasio R; Seghezzi M; Buoro S; Alessio MG
    Clin Chim Acta; 2017 Sep; 472():123-130. PubMed ID: 28760666
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Verification of UriSed 3 PRO automated urine microscope in regional laboratory environment.
    Kouri T; Alagrund K; Lehtonen M; Tohmola N; Pihlajamaa T; Kouri VP; Friman S; Holma T; Kirjavainen V; Pätäri-Sampo A; Lempiäinen A
    Clin Chim Acta; 2021 Apr; 515():96-103. PubMed ID: 33460593
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.
    Shayanfar N; Tobler U; von Eckardstein A; Bestmann L
    Clin Chem Lab Med; 2007; 45(9):1251-6. PubMed ID: 17635081
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The automation of sediment urinalysis using a new urine flow cytometer (UF-100).
    Fenili D; Pirovano B
    Clin Chem Lab Med; 1998 Dec; 36(12):909-17. PubMed ID: 9915222
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of automated devices UX-2000 and SediMAX/AutionMax for urine samples screening: A multicenter Spanish study.
    Sánchez-Mora C; Acevedo D; Porres MA; Chaqués AM; Zapardiel J; Gallego-Cabrera A; López JM; Maesa JM
    Clin Biochem; 2017 Aug; 50(12):714-718. PubMed ID: 28188739
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Urinary sediment features in proliferative and non-proliferative glomerular diseases.
    Fogazzi GB; Saglimbeni L; Banfi G; Cantú M; Moroni G; Garigali G; Cesana BM
    J Nephrol; 2005; 18(6):703-10. PubMed ID: 16358228
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.