These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
125 related articles for article (PubMed ID: 1986203)
1. Monitoring spinal cord function during scoliosis surgery with Cotrel-Dubousset instrumentation. Hicks RG; Burke DJ; Stephen JP Med J Aust; 1991 Jan; 154(2):82-6. PubMed ID: 1986203 [TBL] [Abstract][Full Text] [Related]
2. Neurophysiological detection of impending spinal cord injury during scoliosis surgery. Schwartz DM; Auerbach JD; Dormans JP; Flynn J; Drummond DS; Bowe JA; Laufer S; Shah SA; Bowen JR; Pizzutillo PD; Jones KJ; Drummond DS J Bone Joint Surg Am; 2007 Nov; 89(11):2440-9. PubMed ID: 17974887 [TBL] [Abstract][Full Text] [Related]
3. Cotrel-dubousset instrumentation in children using simultaneous motor and somatosensory evoked potential monitoring. Stephen JP; Sullivan MR; Hicks RG; Burke DJ; Woodforth IJ; Crawford MR Spine (Phila Pa 1976); 1996 Nov; 21(21):2450-7. PubMed ID: 8923630 [TBL] [Abstract][Full Text] [Related]
4. [Contribution of somatosensory evoked potentials in the surveillance of the spinal cord during spinal surgery]. Chéliout-Héraut F; Mariambourg G; Fahed M; De Lattre J; Pouliquen JC Rev Chir Orthop Reparatrice Appar Mot; 1991; 77(5):344-52. PubMed ID: 1836887 [TBL] [Abstract][Full Text] [Related]
5. A system for the electrophysiological monitoring of the spinal cord during operations for scoliosis. Jones SJ; Edgar MA; Ransford AO; Thomas NP J Bone Joint Surg Br; 1983 Mar; 65(2):134-9. PubMed ID: 6826615 [TBL] [Abstract][Full Text] [Related]
6. Somatosensory evoked potential monitoring during Cotrel-Dubousset instrumentation. Report of a case. Booke JS; Banta JV; Bunke FJ; Pelletier C Spine (Phila Pa 1976); 1993 Mar; 18(4):518-21. PubMed ID: 8470015 [TBL] [Abstract][Full Text] [Related]
7. Spinal cord monitoring in scoliosis surgery using an epidural electrode. Results of a prospective, consecutive series of 191 cases. Accadbled F; Henry P; de Gauzy JS; Cahuzac JP Spine (Phila Pa 1976); 2006 Oct; 31(22):2614-23. PubMed ID: 17047554 [TBL] [Abstract][Full Text] [Related]
8. Monitoring scoliosis surgery with combined multiple pulse transcranial electric motor and cortical somatosensory-evoked potentials from the lower and upper extremities. MacDonald DB; Al Zayed Z; Khoudeir I; Stigsby B Spine (Phila Pa 1976); 2003 Jan; 28(2):194-203. PubMed ID: 12544939 [TBL] [Abstract][Full Text] [Related]
9. Assessment of corticospinal and somatosensory conduction simultaneously during scoliosis surgery. Burke D; Hicks R; Stephen J; Woodforth I; Crawford M Electroencephalogr Clin Neurophysiol; 1992 Dec; 85(6):388-96. PubMed ID: 1282457 [TBL] [Abstract][Full Text] [Related]
10. Combined monitoring of motor and somatosensory evoked potentials in orthopaedic spinal surgery. Pelosi L; Lamb J; Grevitt M; Mehdian SM; Webb JK; Blumhardt LD Clin Neurophysiol; 2002 Jul; 113(7):1082-91. PubMed ID: 12088704 [TBL] [Abstract][Full Text] [Related]
11. Intra-operative spinal cord monitoring during surgery for scoliosis using somatosensory evoked potentials. Whittle IR; Johnston IH; Besser M; Taylor TK; Overton J Aust N Z J Surg; 1984 Dec; 54(6):553-7. PubMed ID: 6596075 [TBL] [Abstract][Full Text] [Related]
12. Direct spinal stimulation for intraoperative monitoring during scoliosis surgery. Phillips LH; Blanco JS; Sussman MD Muscle Nerve; 1995 Mar; 18(3):319-25. PubMed ID: 7870110 [TBL] [Abstract][Full Text] [Related]
13. Dissociation of muscle action potentials and spinal somatosensory evoked potentials after ischemic damage of spinal cord. Machida M; Weinstein SL; Yamada T; Kimura J; Toriyama S Spine (Phila Pa 1976); 1988 Oct; 13(10):1119-24. PubMed ID: 3206268 [TBL] [Abstract][Full Text] [Related]
14. Harrington and Cotrel-Dubousset instrumentation in adolescent idiopathic scoliosis. Long-term functional and radiographic outcomes. Helenius I; Remes V; Yrjönen T; Ylikoski M; Schlenzka D; Helenius M; Poussa M J Bone Joint Surg Am; 2003 Dec; 85(12):2303-9. PubMed ID: 14668498 [TBL] [Abstract][Full Text] [Related]
15. Sensory nerve conduction in the human spinal cord: epidural recordings made during scoliosis surgery. Jones SJ; Edgar MA; Ransford AO J Neurol Neurosurg Psychiatry; 1982 May; 45(5):446-51. PubMed ID: 6283032 [TBL] [Abstract][Full Text] [Related]
16. A technique for monitoring evoked potentials during scoliosis and brachial plexus surgery. Anderson SK; Loughnan BA; Hetreed MA Ann R Coll Surg Engl; 1990 Sep; 72(5):321-3. PubMed ID: 2221769 [TBL] [Abstract][Full Text] [Related]
17. Evaluation of various evoked potential techniques for spinal cord monitoring during scoliosis surgery. Luk KD; Hu Y; Wong YW; Cheung KM Spine (Phila Pa 1976); 2001 Aug; 26(16):1772-7. PubMed ID: 11493849 [TBL] [Abstract][Full Text] [Related]
18. Segmental vessel ligation in patients undergoing surgery for anterior spinal deformity. Tsirikos AI; Howitt SP; McMaster MJ J Bone Joint Surg Br; 2008 Apr; 90(4):474-9. PubMed ID: 18378922 [TBL] [Abstract][Full Text] [Related]
19. Spinal cord monitoring during posterior spinal instrumentation and fusion. Bieber E; Tolo V; Uematsu S Clin Orthop Relat Res; 1988 Apr; (229):121-4. PubMed ID: 3280196 [TBL] [Abstract][Full Text] [Related]
20. Surface electrode somatosensory-evoked potentials in spinal surgery: implications for indications and practice. Papastefanou SL; Henderson LM; Smith NJ; Hamilton A; Webb JK Spine (Phila Pa 1976); 2000 Oct; 25(19):2467-72. PubMed ID: 11013498 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]