BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

675 related articles for article (PubMed ID: 19863912)

  • 1. Traceability as a unique tool to improve standardization in laboratory medicine.
    Panteghini M
    Clin Biochem; 2009 Mar; 42(4-5):236-40. PubMed ID: 19863912
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Standardization in laboratory medicine: new challenges.
    Panteghini M; Forest JC
    Clin Chim Acta; 2005 May; 355(1-2):1-12. PubMed ID: 15820472
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Trueness verification and traceability assessment of results from commercial systems for measurement of six enzyme activities in serum: an international study in the EC4 framework of the Calibration 2000 project.
    Jansen R; Schumann G; Baadenhuijsen H; Franck P; Franzini C; Kruse R; Kuypers A; Weykamp C; Panteghini M
    Clin Chim Acta; 2006 Jun; 368(1-2):160-7. PubMed ID: 16516877
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Metrological traceability in clinical biochemistry.
    White GH
    Ann Clin Biochem; 2011 Sep; 48(Pt 5):393-409. PubMed ID: 21795407
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Establishment of working reference materials in laboratory medicine].
    Kuwa K
    Rinsho Byori; 2006 Sep; 54(9):940-6. PubMed ID: 17063876
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Standardization of clinical laboratory data in Japan by the JAMT and JCCLS].
    Hosogaya S
    Rinsho Byori; 2009 Jun; 57(6):579-83. PubMed ID: 19621792
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Procedure for accurate evaluation of laboratory data and its international trends].
    Kuwa K
    Rinsho Byori; 2005 Jun; 53(6):531-9. PubMed ID: 16026081
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Standardization of clinical laboratory testing in Japan].
    Hamasaki N
    Rinsho Byori; 2006 Sep; 54(9):936-9. PubMed ID: 17063875
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Standardization of hapten immunoprocedures: total cortisol.
    Gosling JP; Middle J; Siekmann L; Read G
    Scand J Clin Lab Invest Suppl; 1993; 216():3-41. PubMed ID: 8378749
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Centers for Disease Control-National Heart, Lung and Blood Institute Lipid Standardization Program. An approach to accurate and precise lipid measurements.
    Myers GL; Cooper GR; Winn CL; Smith SJ
    Clin Lab Med; 1989 Mar; 9(1):105-35. PubMed ID: 2538292
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Joint Committee for Traceability in Laboratory Medicine (JCTLM) - its history and operation.
    Jones GR; Jackson C
    Clin Chim Acta; 2016 Jan; 453():86-94. PubMed ID: 26616732
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Nordic Trueness Project 2002: use of reference measurement procedure values in a general clinical chemistry survey.
    Pedersen MM; Ornemark U; Rustad P; Steensland H; Loikkanen M; Olafsdóttir E; Henriksen GM; Jørgensen N; Uldall A; Nordin G; Nordberg UR
    Scand J Clin Lab Invest; 2004; 64(4):309-20. PubMed ID: 15223697
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analytical quality specifications for reference methods and operating specifications for networks of reference laboratories. discussion paper from the members of the external quality assessment (EQA) Working Group B1) on target values in EQAS.
    Thienpont L; Franzini C; Kratochvila J; Middle J; Ricós C; Siekmann L; Stöckl D
    Eur J Clin Chem Clin Biochem; 1995 Dec; 33(12):949-57. PubMed ID: 8845428
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Achieving accuracy for routine clinical chemistry methods by using patient specimen correlations to assign calibrator values. A means of managing matrix effects.
    Lasky FD
    Arch Pathol Lab Med; 1993 Apr; 117(4):412-9. PubMed ID: 8466405
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Metrological traceability of values for alpha-amylase catalytic concentration assigned to a commutable calibrator materials.
    Canalias F; García E; Sánchez M
    Clin Chim Acta; 2010 Jan; 411(1-2):7-12. PubMed ID: 19799891
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prerequisites for establishing common reference intervals.
    Hyltoft Petersen P; Rustad P
    Scand J Clin Lab Invest; 2004; 64(4):285-92. PubMed ID: 15223695
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of reference method values by isotope dilution-gas chromatography/mass spectrometry: a five years' experience of two European Reference Laboratories.
    Thienpont LM; Van Nieuwenhove B; Stöckl D; Reinauer H; De Leenheer AP
    Eur J Clin Chem Clin Biochem; 1996 Oct; 34(10):853-60. PubMed ID: 8933112
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Introduction to standardization of laboratory results.
    Myers GL
    Steroids; 2008 Dec; 73(13):1293-6. PubMed ID: 18652837
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Point of view regarding traceability and measurement uncertainty in medical laboratory accreditation].
    Kubono K
    Rinsho Byori; 2009 Jun; 57(6):584-92. PubMed ID: 19621793
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Implementation of metrological traceability in laboratory medicine: where we are and what is missing.
    Panteghini M; Braga F
    Clin Chem Lab Med; 2020 Jul; 58(8):1200-1204. PubMed ID: 32069227
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 34.