961 related articles for article (PubMed ID: 19865628)
1. Effects of implant diameter, insertion depth, and loading angle on stress/strain fields in implant/jawbone systems: finite element analysis.
Qian L; Todo M; Matsushita Y; Koyano K
Int J Oral Maxillofac Implants; 2009; 24(5):877-86. PubMed ID: 19865628
[TBL] [Abstract][Full Text] [Related]
2. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.
Ding X; Zhu XH; Liao SH; Zhang XH; Chen H
J Prosthodont; 2009 Jul; 18(5):393-402. PubMed ID: 19374710
[TBL] [Abstract][Full Text] [Related]
3. Effect of diameter and length on stress distribution of the alveolar crest around immediate loading implants.
Ding X; Liao SH; Zhu XH; Zhang XH; Zhang L
Clin Implant Dent Relat Res; 2009 Dec; 11(4):279-87. PubMed ID: 18783411
[TBL] [Abstract][Full Text] [Related]
4. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis.
Tada S; Stegaroiu R; Kitamura E; Miyakawa O; Kusakari H
Int J Oral Maxillofac Implants; 2003; 18(3):357-68. PubMed ID: 12814310
[TBL] [Abstract][Full Text] [Related]
5. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis.
Baggi L; Cappelloni I; Di Girolamo M; Maceri F; Vairo G
J Prosthet Dent; 2008 Dec; 100(6):422-31. PubMed ID: 19033026
[TBL] [Abstract][Full Text] [Related]
6. Influence of bone and dental implant parameters on stress distribution in the mandible: a finite element study.
Guan H; van Staden R; Loo YC; Johnson N; Ivanovski S; Meredith N
Int J Oral Maxillofac Implants; 2009; 24(5):866-76. PubMed ID: 19865627
[TBL] [Abstract][Full Text] [Related]
7. The biomechanical analysis of simulating implants in function under osteoporotic jawbone by comparing cylindrical, apical tapered, neck tapered, and expandable type implants: a 3-dimensional finite element analysis.
Xiao JR; Li YF; Guan SM; Song L; Xu LX; Kong L
J Oral Maxillofac Surg; 2011 Jul; 69(7):e273-81. PubMed ID: 21367505
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of optimal taper of immediately loaded wide-diameter implants: a finite element analysis.
Atieh MA; Shahmiri RA
J Oral Implantol; 2013 Apr; 39(2):123-32. PubMed ID: 21905902
[TBL] [Abstract][Full Text] [Related]
9. Selection of the implant transgingival height for optimal biomechanical properties: a three-dimensional finite element analysis.
Sun Y; Kong L; Hu K; Xie C; Zhou H; Liu Y; Liu B
Br J Oral Maxillofac Surg; 2009 Jul; 47(5):393-8. PubMed ID: 18977057
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis.
Kong L; Hu K; Li D; Song Y; Yang J; Wu Z; Liu B
Int J Oral Maxillofac Implants; 2008; 23(1):65-74. PubMed ID: 18416414
[TBL] [Abstract][Full Text] [Related]
11. Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis.
Petrie CS; Williams JL
Clin Oral Implants Res; 2005 Aug; 16(4):486-94. PubMed ID: 16117775
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of multiple implant-bone parameters on stress characteristics in the mandible under traumatic loading conditions.
Guan H; van Staden R; Loo YC; Johnson N; Ivanovski S; Meredith N
Int J Oral Maxillofac Implants; 2010; 25(3):461-72. PubMed ID: 20556244
[TBL] [Abstract][Full Text] [Related]
13. Numeric simulation of time-dependent remodeling of bone around loaded oral implants.
Eser A; Tonuk E; Akca K; Cehreli MC
Int J Oral Maxillofac Implants; 2009; 24(4):597-608. PubMed ID: 19885399
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical effect of platform switching in implant dentistry: a three-dimensional finite element analysis.
Chang CL; Chen CS; Hsu ML
Int J Oral Maxillofac Implants; 2010; 25(2):295-304. PubMed ID: 20369087
[TBL] [Abstract][Full Text] [Related]
15. Influence of clinically relevant factors on the immediate biomechanical surrounding for a series of dental implant designs.
Shunmugasamy VC; Gupta N; Pessoa RS; Janal MN; Coelho PG
J Biomech Eng; 2011 Mar; 133(3):031005. PubMed ID: 21303181
[TBL] [Abstract][Full Text] [Related]
16. Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures.
Tanino F; Hayakawa I; Hirano S; Minakuchi S
Int J Prosthodont; 2007; 20(2):193-8. PubMed ID: 17455444
[TBL] [Abstract][Full Text] [Related]
17. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone.
Sütpideler M; Eckert SE; Zobitz M; An KN
Int J Oral Maxillofac Implants; 2004; 19(6):819-25. PubMed ID: 15623056
[TBL] [Abstract][Full Text] [Related]
18. Micromotion and stress distribution of immediate loaded implants: a finite element analysis.
Fazel A; Aalai S; Rismanchian M; Sadr-Eshkevari P
Clin Implant Dent Relat Res; 2009 Dec; 11(4):267-71. PubMed ID: 18783413
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.
Merıç G; Erkmen E; Kurt A; Eser A; özden AU
Acta Odontol Scand; 2011 Nov; 69(6):374-84. PubMed ID: 21449688
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical effects of a maxillary implant in the augmented sinus: a three-dimensional finite element analysis.
Huang HL; Fuh LJ; Ko CC; Hsu JT; Chen CC
Int J Oral Maxillofac Implants; 2009; 24(3):455-62. PubMed ID: 19587867
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]