These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

356 related articles for article (PubMed ID: 19882199)

  • 21. The clinical assessment of Glidescope in orotracheal intubation under general anesthesia.
    Xue FS; Zhang GH; Liu J; Li XY; Yang QY; Xu YC; Li CW
    Minerva Anestesiol; 2007 Sep; 73(9):451-7. PubMed ID: 17660737
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of the C-MAC videolaryngoscope with the Macintosh, Glidescope, and Airtraq laryngoscopes in easy and difficult laryngoscopy scenarios in manikins.
    McElwain J; Malik MA; Harte BH; Flynn NM; Laffey JG
    Anaesthesia; 2010 May; 65(5):483-9. PubMed ID: 20337620
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A randomized comparison of the GlideScope videolaryngoscope to the standard laryngoscopy for intubation by pediatric residents in simulated easy and difficult infant airway scenarios.
    Fonte M; Oulego-Erroz I; Nadkarni L; Sánchez-Santos L; Iglesias-Vásquez A; Rodríguez-Núñez A
    Pediatr Emerg Care; 2011 May; 27(5):398-402. PubMed ID: 21494161
    [TBL] [Abstract][Full Text] [Related]  

  • 24. GlideScope videolaryngoscope vs. Macintosh direct laryngoscope for intubation of morbidly obese patients: a randomized trial.
    Andersen LH; Rovsing L; Olsen KS
    Acta Anaesthesiol Scand; 2011 Oct; 55(9):1090-7. PubMed ID: 22092206
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Early Endotracheal Tube Insertion with the GlideScope: A Randomized Controlled Trial.
    Turkstra TP; Cusano F; Fridfinnson JA; Batohi P; Rachinsky M
    Anesth Analg; 2016 Mar; 122(3):753-757. PubMed ID: 26771266
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of stylet angulation and endotracheal tube camber on time to intubation with the GlideScope.
    Jones PM; Turkstra TP; Armstrong KP; Armstrong PM; Cherry RA; Hoogstra J; Harle CC
    Can J Anaesth; 2007 Jan; 54(1):21-7. PubMed ID: 17197464
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A mannequin study of intubation with the AP advance and GlideScope Ranger videolaryngoscopes and the Macintosh laryngoscope.
    Hodd JA; Doyle DJ; Gupta S; Dalton JE; Cata JP; Brewer EJ; James M; Sessler DI
    Anesth Analg; 2011 Oct; 113(4):791-800. PubMed ID: 21890882
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Airway management in pediatric patients using the Glidescope Cobalt®: a feasibility study.
    Ilies C; Fudickar A; Thee C; Dütschke P; Hanss R; Doerges V; Bein B
    Minerva Anestesiol; 2012 Sep; 78(9):1019-25. PubMed ID: 22643539
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A deliberately restricted laryngeal view with the GlideScope® video laryngoscope is associated with faster and easier tracheal intubation when compared with a full glottic view: a randomized clinical trial.
    Gu Y; Robert J; Kovacs G; Milne AD; Morris I; Hung O; MacQuarrie K; Mackinnon S; Adam Law J
    Can J Anaesth; 2016 Aug; 63(8):928-37. PubMed ID: 27090535
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparing the novel GlideScope Groove videolaryngoscope with conventional videolaryngoscopy: a randomized mannequin study of novice providers.
    Tung A; Griesdale DE
    J Clin Anesth; 2013 Dec; 25(8):644-50. PubMed ID: 24095892
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A comparison of three videolaryngoscopes: the Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients.
    Maassen R; Lee R; Hermans B; Marcus M; van Zundert A
    Anesth Analg; 2009 Nov; 109(5):1560-5. PubMed ID: 19713258
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Comparison of hemodynamic responses to orotracheal intubation between using GlideScope videolaryngoscope and fiberoptic bronchoscope].
    Zhang GH; Xue FS; Li CW; Sun HY; Li XY; Sun HT; Liu KP
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2006 Jun; 28(3):406-9. PubMed ID: 16900645
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of the Truview PCD™ and the GlideScope(®) video laryngoscopes with direct laryngoscopy in pediatric patients: a randomized trial.
    Riveros R; Sung W; Sessler DI; Sanchez IP; Mendoza ML; Mascha EJ; Niezgoda J
    Can J Anaesth; 2013 May; 60(5):450-7. PubMed ID: 23435693
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Does the incidence of sore throat postoperatively increase with the use of a traditional intubation blade or the GlideScope?
    Cirilla DJ; Ngo J; Vaisman V; Daly C; Ata A; Sandison M; Roberts K
    J Clin Anesth; 2015 Dec; 27(8):646-51. PubMed ID: 26277231
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A comparison between the GlideScope Video Laryngoscope and direct laryngoscope in paediatric patients with difficult airways - a pilot study.
    Armstrong J; John J; Karsli C
    Anaesthesia; 2010 Apr; 65(4):353-7. PubMed ID: 20402873
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The Shikani optical stylet as an alternative to the GlideScope® videolaryngoscope in simulated difficult intubations--a randomised controlled trial.
    Phua DS; Mah CL; Wang CF
    Anaesthesia; 2012 Apr; 67(4):402-6. PubMed ID: 22324890
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Circulatory responses to nasotracheal intubation: comparison of GlideScope videolaryngoscope and Macintosh direct laryngoscope.
    Xue FS; Li XY; Liu QJ; Liu HP; Yang QY; Xu YC; Liao X; Liu Y
    Chin Med J (Engl); 2008 Jul; 121(14):1290-6. PubMed ID: 18713550
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of the GlideScope video laryngoscope vs. the intubating laryngeal mask for females with normal airways.
    Fun WL; Lim Y; Teoh WH
    Eur J Anaesthesiol; 2007 Jun; 24(6):486-91. PubMed ID: 17202013
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of the Pentax AirwayScope and McGrath MAC videolaryngoscope for endotracheal intubation in patients with a normal airway.
    Lee J; Kwak HJ; Lee JY; Chang MY; Lee SY; Kim JY
    Medicine (Baltimore); 2017 Nov; 96(46):e8713. PubMed ID: 29145308
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Utilization of a Glidescope videolaryngoscope for orotracheal intubations in different emergency airway management settings.
    Lim HC; Goh SH
    Eur J Emerg Med; 2009 Apr; 16(2):68-73. PubMed ID: 18832996
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.