These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 19884066)

  • 1. Effects of different imaging models on least-squares image reconstruction accuracy in photoacoustic tomography.
    Zhang J; Anastasio MA; La Riviere PJ; Wang LV
    IEEE Trans Med Imaging; 2009 Nov; 28(11):1781-90. PubMed ID: 19884066
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A reconstruction algorithm for photoacoustic imaging based on the nonuniform FFT.
    Haltmeier M; Scherzer O; Zangerl G
    IEEE Trans Med Imaging; 2009 Nov; 28(11):1727-35. PubMed ID: 19884063
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Artifact trapping during time reversal photoacoustic imaging for acoustically heterogeneous media.
    Cox BT; Treeby BE
    IEEE Trans Med Imaging; 2010 Feb; 29(2):387-96. PubMed ID: 19887310
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On a limited-view reconstruction problem in diffraction tomography.
    Pan X; Anastasio MA
    IEEE Trans Med Imaging; 2002 Apr; 21(4):413-6. PubMed ID: 12022629
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Limited-view photoacoustic imaging based on an iterative adaptive weighted filtered backprojection approach.
    Liu X; Peng D; Ma X; Guo W; Liu Z; Han D; Yang X; Tian J
    Appl Opt; 2013 May; 52(15):3477-83. PubMed ID: 23736232
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A wavelet-based multiresolution regularized least squares reconstruction approach for optical tomography.
    Zhu W; Wang Y; Deng Y; Yao Y; Barbour RL
    IEEE Trans Med Imaging; 1997 Apr; 16(2):210-7. PubMed ID: 9101330
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of the penalty on the penalized weighted least-squares image reconstruction for low-dose CBCT.
    Ouyang L; Solberg T; Wang J
    Phys Med Biol; 2011 Sep; 56(17):5535-52. PubMed ID: 21813958
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Model-based reconstruction integrated with fluence compensation for photoacoustic tomography.
    Bu S; Liu Z; Shiina T; Kondo K; Yamakawa M; Fukutani K; Someda Y; Asao Y
    IEEE Trans Biomed Eng; 2012 May; 59(5):1354-63. PubMed ID: 22345521
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Improving tangential resolution with a modified delay-and-sum reconstruction algorithm in photoacoustic and thermoacoustic tomography.
    Pramanik M
    J Opt Soc Am A Opt Image Sci Vis; 2014 Mar; 31(3):621-7. PubMed ID: 24690661
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo impedance imaging with total variation regularization.
    Borsic A; Graham BM; Adler A; Lionheart WR
    IEEE Trans Med Imaging; 2010 Jan; 29(1):44-54. PubMed ID: 20051330
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Video-rate compressive holographic microscopic tomography.
    Hahn J; Lim S; Choi K; Horisaki R; Brady DJ
    Opt Express; 2011 Apr; 19(8):7289-98. PubMed ID: 21503040
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Image reconstruction in phase-contrast tomography exploiting the second-order statistical properties of the projection data.
    Chou CY; Huang PY
    Opt Express; 2011 Nov; 19(24):24396-410. PubMed ID: 22109467
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gradient-based iterative image reconstruction scheme for time-resolved optical tomography.
    Hielscher AH; Klose AD; Hanson KM
    IEEE Trans Med Imaging; 1999 Mar; 18(3):262-71. PubMed ID: 10363704
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The application of compressed sensing for photo-acoustic tomography.
    Provost J; Lesage F
    IEEE Trans Med Imaging; 2009 Apr; 28(4):585-94. PubMed ID: 19272991
    [TBL] [Abstract][Full Text] [Related]  

  • 15. ISWLS: novel algorithm for image reconstruction in PET.
    Karali E; Pavlopoulos S; Lambropoulou S; Koutsouris D
    IEEE Trans Inf Technol Biomed; 2011 May; 15(3):381-6. PubMed ID: 21216719
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative multispectral photoacoustic tomography and wavelength optimization.
    Xiao J; Yuan Z; He J; Jiang H
    J Xray Sci Technol; 2010; 18(4):415-27. PubMed ID: 21045278
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A method for accurate modelling of the crystal response function at a crystal sub-level applied to PET reconstruction.
    Stute S; Benoit D; Martineau A; Rehfeld NS; Buvat I
    Phys Med Biol; 2011 Feb; 56(3):793-809. PubMed ID: 21239844
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Weighted model-based optoacoustic reconstruction in acoustic scattering media.
    Deán-Ben XL; Ma R; Rosenthal A; Ntziachristos V; Razansky D
    Phys Med Biol; 2013 Aug; 58(16):5555-66. PubMed ID: 23892587
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Accurate model-based reconstruction algorithm for three-dimensional optoacoustic tomography.
    Deán-Ben XL; Buehler A; Ntziachristos V; Razansky D
    IEEE Trans Med Imaging; 2012 Oct; 31(10):1922-8. PubMed ID: 23033065
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Curve-Driven-Based Acoustic Inversion for Photoacoustic Tomography.
    Liu H; Wang K; Peng D; Li H; Zhu Y; Zhang S; Liu M; Tian J
    IEEE Trans Med Imaging; 2016 Dec; 35(12):2546-2557. PubMed ID: 27352391
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.