These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
135 related articles for article (PubMed ID: 19889565)
1. Total hip joint prosthesis for in vivo measurement of forces and moments. Damm P; Graichen F; Rohlmann A; Bender A; Bergmann G Med Eng Phys; 2010 Jan; 32(1):95-100. PubMed ID: 19889565 [TBL] [Abstract][Full Text] [Related]
2. Design, calibration and pre-clinical testing of an instrumented tibial tray. Heinlein B; Graichen F; Bender A; Rohlmann A; Bergmann G J Biomech; 2007; 40 Suppl 1():S4-10. PubMed ID: 17433815 [TBL] [Abstract][Full Text] [Related]
3. An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column. Rohlmann A; Gabel U; Graichen F; Bender A; Bergmann G Med Eng Phys; 2007 Jun; 29(5):580-5. PubMed ID: 16931099 [TBL] [Abstract][Full Text] [Related]
4. Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants. Graichen F; Arnold R; Rohlmann A; Bergmann G IEEE Trans Biomed Eng; 2007 Feb; 54(2):253-61. PubMed ID: 17278582 [TBL] [Abstract][Full Text] [Related]
5. Direct real-time measurement of in vivo forces in the lumbar spine. Ledet EH; Tymeson MP; DiRisio DJ; Cohen B; Uhl RL Spine J; 2005; 5(1):85-94. PubMed ID: 15653089 [TBL] [Abstract][Full Text] [Related]
6. An instrumented implant for in vivo measurement of contact forces and contact moments in the shoulder joint. Westerhoff P; Graichen F; Bender A; Rohlmann A; Bergmann G Med Eng Phys; 2009 Mar; 31(2):207-13. PubMed ID: 18789749 [TBL] [Abstract][Full Text] [Related]
8. Hip endoprosthesis for in vivo measurement of joint force and temperature. Graichen F; Bergmann G; Rohlmann A J Biomech; 1999 Oct; 32(10):1113-7. PubMed ID: 10476850 [TBL] [Abstract][Full Text] [Related]
11. Four-channel telemetry system for in vivo measurement of hip joint forces. Graichen F; Bergmann G J Biomed Eng; 1991 Sep; 13(5):370-4. PubMed ID: 1795503 [TBL] [Abstract][Full Text] [Related]
12. Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty. Cheal EJ; Spector M; Hayes WC J Orthop Res; 1992 May; 10(3):405-22. PubMed ID: 1569504 [TBL] [Abstract][Full Text] [Related]
13. ESB Clinical Biomechanics Award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10 months. Heinlein B; Kutzner I; Graichen F; Bender A; Rohlmann A; Halder AM; Beier A; Bergmann G Clin Biomech (Bristol); 2009 May; 24(4):315-26. PubMed ID: 19285767 [TBL] [Abstract][Full Text] [Related]
14. [A comparative study of the characteristics of femoral hip prosthesis heads--study and results ceramic-coated hip joint heads of titanium]. Hennig FF; von Kroge H; Repenning D Biomed Tech (Berl); 1992 Sep; 37(9):200-4. PubMed ID: 1391607 [TBL] [Abstract][Full Text] [Related]
15. Telemeterized in vivo hip joint force data: a report on two patients after total hip surgery. Kotzar GM; Davy DT; Goldberg VM; Heiple KG; Berilla J; Heiple KG; Brown RH; Burstein AH J Orthop Res; 1991 Sep; 9(5):621-33. PubMed ID: 1870027 [TBL] [Abstract][Full Text] [Related]
16. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses]. Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433 [TBL] [Abstract][Full Text] [Related]
17. Friction moments of large metal-on-metal hip joint bearings and other modern designs. Bishop NE; Waldow F; Morlock MM Med Eng Phys; 2008 Oct; 30(8):1057-64. PubMed ID: 18291702 [TBL] [Abstract][Full Text] [Related]
18. [In vivo measurement of hip joint stress. 1. Physical therapy]. Bergmann G; Rohlmann A; Graichen F Z Orthop Ihre Grenzgeb; 1989; 127(6):672-9. PubMed ID: 2618148 [TBL] [Abstract][Full Text] [Related]
19. Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine. Wilson DC; Niosi CA; Zhu QA; Oxland TR; Wilson DR J Biomech; 2006; 39(2):348-53. PubMed ID: 16321637 [TBL] [Abstract][Full Text] [Related]
20. Design and implementation of an instrumented ulnar head prosthesis to measure loads in vitro. Gordon KD; Kedgley AE; Ferreira LM; King GJ; Johnson JA J Biomech; 2006; 39(7):1335-41. PubMed ID: 15885698 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]