BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

309 related articles for article (PubMed ID: 19892555)

  • 1. Numerical expressions for the computation of coincidence-summing correction factors in gamma-ray spectrometry with HPGe detectors.
    Rizzo S; Tomarchio E
    Appl Radiat Isot; 2010; 68(4-5):555-60. PubMed ID: 19892555
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental and MC determination of HPGe detector efficiency in the 40-2754 keV energy range for measuring point source geometry with the source-to-detector distance of 25 cm.
    Dryak P; Kovar P
    Appl Radiat Isot; 2006; 64(10-11):1346-9. PubMed ID: 16564693
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Close-geometry efficiency calibration of p-type HPGe detectors with a Cs-134 point source.
    DeFelice P; Fazio A; Vidmar T; Korun M
    Appl Radiat Isot; 2006; 64(10-11):1303-6. PubMed ID: 16549352
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental validation of coincidence summing corrections computed by the ETNA software.
    Lépy MC; Brun P; Collin C; Plagnard J
    Appl Radiat Isot; 2006; 64(10-11):1340-5. PubMed ID: 16600602
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calculation of coincidence summing corrections for X-ray peaks and for sum peaks with X-ray contributions.
    Arnold D; Sima O
    Appl Radiat Isot; 2006; 64(10-11):1297-302. PubMed ID: 16678431
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved neutron detection by gamma-ray spectroscopy.
    Alfassi ZB; Zlatin T; Manor O; Dubinsky S; German U
    Radiat Prot Dosimetry; 2004; 110(1-4):207-11. PubMed ID: 15353646
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The coincidence-summing correction of the Compton-suppression spectrometer.
    Fan YQ; Wang J; Wang SL; Zhang XJ; Li Q
    Appl Radiat Isot; 2012 Sep; 70(9):2124-6. PubMed ID: 22405959
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of GESPECOR software for the calculation of coincidence summing effects in special cases.
    Arnold D; Sima O
    Appl Radiat Isot; 2004; 60(2-4):167-72. PubMed ID: 14987637
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Activity measurement of a 176Lu sample using coincidence peaks and Monte Carlo simulations.
    Jutier C; Le Petit G
    Appl Radiat Isot; 2006; 64(10-11):1292-6. PubMed ID: 16603370
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application of PENELOPE code to the efficiency calibration of coaxial germanium detectors.
    Jurado Vargas M; Guerra AL
    Appl Radiat Isot; 2006; 64(10-11):1319-22. PubMed ID: 16549348
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of peak and total efficiencies of low-energy gamma-ray detectors with sources emitting photons in cascade.
    Korun M
    Appl Radiat Isot; 2004; 60(2-4):207-11. PubMed ID: 14987644
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intercomparison of methods for coincidence summing corrections in gamma-ray spectrometry--part II (volume sources).
    Lépy MC; Altzitzoglou T; Anagnostakis MJ; Capogni M; Ceccatelli A; De Felice P; Djurasevic M; Dryak P; Fazio A; Ferreux L; Giampaoli A; Han JB; Hurtado S; Kandic A; Kanisch G; Karfopoulos KL; Klemola S; Kovar P; Laubenstein M; Lee JH; Lee JM; Lee KB; Pierre S; Carvalhal G; Sima O; Tao CV; Thanh TT; Vidmar T; Vukanac I; Yang MJ
    Appl Radiat Isot; 2012 Sep; 70(9):2112-8. PubMed ID: 22445105
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cascade summing effects in close geometry gamma-ray spectrometry.
    Johnston PN; Hult M; Gasparro J
    Appl Radiat Isot; 2006; 64(10-11):1323-8. PubMed ID: 16580218
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On the invariability of the total-to-peak ratio in gamma-ray spectrometry.
    Vidmar T; Likar A
    Appl Radiat Isot; 2004; 60(2-4):191-5. PubMed ID: 14987641
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New numerical algorithm method to calibrate the HPGe cylindrical detectors using non-axial extended source geometries.
    Nafee SS; Badawi MS; Ahmed AH
    Appl Radiat Isot; 2010 Sep; 68(9):1809-15. PubMed ID: 20395155
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Calculation of true coincidence summing corrections for extended sources with EFFTRAN.
    Vidmar T; Kanisch G; Vidmar G
    Appl Radiat Isot; 2011 Jun; 69(6):908-11. PubMed ID: 21397512
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-energy resolution X-ray, gamma and electron spectroscopy with cryogenic detectors.
    Loidl M; Leblanc E; Bouchard J; Branger T; Coron N; Leblanc J; de Marcillac P; Rotzinger H; Daniyarov T; Linck M; Fleischmann A; Enss C
    Appl Radiat Isot; 2004; 60(2-4):363-8. PubMed ID: 14987669
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative measurements in dose calibrators and a gamma-ray spectrometer.
    Koskinas MF; Yamazaki IM; Bessa AC; Caldas LV; Dias MS
    Appl Radiat Isot; 2010; 68(4-5):589-91. PubMed ID: 19822439
    [TBL] [Abstract][Full Text] [Related]  

  • 19. On line gamma-ray spectrometry at open sea.
    Tsabaris C; Ballas D
    Appl Radiat Isot; 2005 Jan; 62(1):83-9. PubMed ID: 15498689
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intrinsic error of the point-source and the LS-curve approximations in treatment of true coincidence summing.
    Vidmar T; Kanisch G
    Appl Radiat Isot; 2010 Sep; 68(9):1785-8. PubMed ID: 20303773
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.