These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 19892594)

  • 1. Pressure stability with CPAP devices: A bench evaluation.
    Louis B; Leroux K; Boucherie M; Isabey D; Grillier-Lanoir V; Fauroux B; Lofaso F
    Sleep Med; 2010 Jan; 11(1):96-9. PubMed ID: 19892594
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of continuous positive airway pressure/positive end-expiratory pressure and pressure-support ventilation on work of breathing, using an animal model.
    Heulitt MJ; Holt SJ; Wilson S; Hall RA
    Respir Care; 2003 Jul; 48(7):689-96. PubMed ID: 12841860
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of imposed resistance on tidal volume with 5 neonatal nasal continuous positive airway pressure systems.
    Cook SE; Fedor KL; Chatburn RL
    Respir Care; 2010 May; 55(5):544-8. PubMed ID: 20420723
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Changes in lung volume and work of breathing: A comparison of two variable-flow nasal continuous positive airway pressure devices in very low birth weight infants.
    Courtney SE; Aghai ZH; Saslow JG; Pyon KH; Habib RH
    Pediatr Pulmonol; 2003 Sep; 36(3):248-52. PubMed ID: 12910587
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of volume and leak measurements during CPAP using a neonatal lung model.
    Fischer HS; Roehr CC; Proquitté H; Wauer RR; Schmalisch G
    Physiol Meas; 2008 Jan; 29(1):95-107. PubMed ID: 18175862
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Characteristics of auto-CPAP devices during the simulation of sleep-related breathing flow patterns].
    Rühle KH; Karweina D; Domanski U; Nilius G
    Pneumologie; 2009 Jul; 63(7):390-8. PubMed ID: 19591085
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of continuous, expiratory, reverse, and bi-directional tracheal gas insufflation in conjunction with a flow relief valve on delivered tidal volume, total positive end-expiratory pressure, and carbon dioxide elimination: a bench study.
    Delgado E; Hete B; Hoffman LA; Tasota FJ; Pinsky MR
    Respir Care; 2001 Jun; 46(6):577-85. PubMed ID: 11353546
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bench study of auto-CPAP devices using a collapsible upper airway model with upstream resistance.
    Hirose M; Honda J; Sato E; Shinbo T; Kokubo K; Ichiwata T; Kobayashi H
    Respir Physiol Neurobiol; 2008 Jun; 162(1):48-54. PubMed ID: 18499537
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Work of breathing during constant- and variable-flow nasal continuous positive airway pressure in preterm neonates.
    Pandit PB; Courtney SE; Pyon KH; Saslow JG; Habib RH
    Pediatrics; 2001 Sep; 108(3):682-5. PubMed ID: 11533336
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of seven infant continuous positive airway pressure systems using simulated neonatal breathing.
    Drevhammar T; Nilsson K; Zetterström H; Jonsson B
    Pediatr Crit Care Med; 2012 Mar; 13(2):e113-9. PubMed ID: 21946854
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical effects of airway humidification devices in difficult to wean patients.
    Girault C; Breton L; Richard JC; Tamion F; Vandelet P; Aboab J; Leroy J; Bonmarchand G
    Crit Care Med; 2003 May; 31(5):1306-11. PubMed ID: 12771595
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Technical differences in various CPAP and BiLevel CPAP devices].
    Netzer N; Kirbas G; Matthys H; Werner P
    Pneumologie; 1997 Aug; 51 Suppl 3():789-95. PubMed ID: 9340643
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nasal continuous positive airway pressure devices do not maintain the set pressure dynamically when tested under simulated clinical conditions.
    Bacon JP; Farney RJ; Jensen RL; Walker JM; Cloward TV
    Chest; 2000 Nov; 118(5):1441-9. PubMed ID: 11083699
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Aerosol delivery and humidification with the Boussignac continuous positive airway pressure device.
    Thille AW; Bertholon JF; Becquemin MH; Roy M; Lyazidi A; Lellouche F; Pertusini E; Boussignac G; Maître B; Brochard L
    Respir Care; 2011 Oct; 56(10):1526-32. PubMed ID: 21513584
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Synchronized nasal intermittent positive pressure ventilation (SNIPPV) decreases work of breathing (WOB) in premature infants with respiratory distress syndrome (RDS) compared to nasal continuous positive airway pressure (NCPAP).
    Aghai ZH; Saslow JG; Nakhla T; Milcarek B; Hart J; Lawrysh-Plunkett R; Stahl G; Habib RH; Pyon KH
    Pediatr Pulmonol; 2006 Sep; 41(9):875-81. PubMed ID: 16850439
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Nasal continuous positive airway pressure (CPAP) for the respiratory care of the newborn infant.
    Diblasi RM
    Respir Care; 2009 Sep; 54(9):1209-35. PubMed ID: 19712498
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Decreased imposed work with a new nasal continuous positive airway pressure device.
    Klausner JF; Lee AY; Hutchison AA
    Pediatr Pulmonol; 1996 Sep; 22(3):188-94. PubMed ID: 8893258
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of different techniques to measure air leaks during CPAP treatment in neonates.
    Schmalisch G; Fischer H; Roehr CC; Proquitté H
    Med Eng Phys; 2009 Jan; 31(1):124-30. PubMed ID: 18554973
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Do turbines with servo-controlled speed improve continuous positive airway pressure generation?
    Lofaso F; Heyer L; Leroy A; Lorino H; Harf A; Isabey D
    Eur Respir J; 1994 Nov; 7(11):2077-81. PubMed ID: 7875284
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.