142 related articles for article (PubMed ID: 19893701)
1. Dosimetric evaluation of 120-leaf multileaf collimator in a Varian linear accelerator with 6-MV and 18-MV photon beams.
Mohan R; Jayesh K; Joshi RC; Al-Idrisi M; Narayanamurthy P; Majumdar SK
J Med Phys; 2008 Jul; 33(3):114-8. PubMed ID: 19893701
[TBL] [Abstract][Full Text] [Related]
2. Comparison of dosimetric characteristics of 120-leaf and 80-leaf multi-leaf collimators in a Varian linear accelerator for a 6-MV photon beam.
Mohan R; Jayesh K; Joshi RC; Narayanamurthy P; Majumdar SK; Al-Idirisi M
Radiol Phys Technol; 2008 Jul; 1(2):223-8. PubMed ID: 20821151
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of dosimetric effect of leaf position in a radiation field of an 80 leaf multileaf collimator fitted to the LINAC head as tertiary collimator.
Kehwar TS; Bhardwaj AK; Chakarvarti SK
J Appl Clin Med Phys; 2006 Aug; 7(3):43-54. PubMed ID: 17533348
[TBL] [Abstract][Full Text] [Related]
4. [Dosimetric characterization of a multileaf collimator].
Stasi M; Baiotto B; Palamara F; Gabriele P; Scielzo G
Radiol Med; 1999 May; 97(5):382-8. PubMed ID: 10432971
[TBL] [Abstract][Full Text] [Related]
5. Poster - Thurs Eve-24: Dosimetry study on the penumbra region for the irregular MLC fields with stepping patterns.
Chow J; Jiang R; Grigorov G
Med Phys; 2008 Jul; 35(7Part2):3405-3406. PubMed ID: 28512823
[TBL] [Abstract][Full Text] [Related]
6. Matching extended-SSD electron beams to multileaf collimated photon beams in the treatment of head and neck cancer.
Steel J; Stewart A; Satory P
Med Phys; 2009 Sep; 36(9):4244-9. PubMed ID: 19810498
[TBL] [Abstract][Full Text] [Related]
7. [Physical-dosimetric characterization of a multi-leaf collimator system for clinical implementation in conformational radiotherapy].
Pasquino M; Casanova Borca V; Tofani S
Radiol Med; 2001 Mar; 101(3):187-92. PubMed ID: 11402959
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of Dosimetric Effect of Millennium and High Definition Multi Leaf Collimator Using 6 MV Photon Beams.
Raj A; Khanna D; Vt H; Padmanabhan S; Mohandass P
Asian Pac J Cancer Prev; 2021 Dec; 22(12):3883-3888. PubMed ID: 34967567
[TBL] [Abstract][Full Text] [Related]
9. Dosimetric characteristics of a commercial multileaf collimator.
Huq MS; Yu Y; Chen ZP; Suntharalingam N
Med Phys; 1995 Feb; 22(2):241-7. PubMed ID: 7565356
[TBL] [Abstract][Full Text] [Related]
10. Commissioning an Elekta Versa HD linear accelerator.
Narayanasamy G; Saenz D; Cruz W; Ha CS; Papanikolaou N; Stathakis S
J Appl Clin Med Phys; 2016 Jan; 17(1):179-191. PubMed ID: 26894351
[TBL] [Abstract][Full Text] [Related]
11. A feasibility study of Dynamic Phantom scanner for quality assurance of photon beam profiles at various gantry angles.
Zhang Y; Hsi WC; Chu JC; Bernard DB; Abrams RA
J Appl Clin Med Phys; 2005; 6(2):50-61. PubMed ID: 15940212
[TBL] [Abstract][Full Text] [Related]
12. Beam characteristics of a retrofitted double-focused multileaf collimator.
Das IJ; Desobry GE; McNeeley SW; Cheng EC; Schultheiss TE
Med Phys; 1998 Sep; 25(9):1676-84. PubMed ID: 9775373
[TBL] [Abstract][Full Text] [Related]
13. Properties of unflattened photon beams shaped by a multileaf collimator.
Pönisch F; Titt U; Vassiliev ON; Kry SF; Mohan R
Med Phys; 2006 Jun; 33(6):1738-46. PubMed ID: 16872081
[TBL] [Abstract][Full Text] [Related]
14. A dosimetric comparison of various multileaf collimators.
Huq MS; Das IJ; Steinberg T; Galvin JM
Phys Med Biol; 2002 Jun; 47(12):N159-70. PubMed ID: 12118609
[TBL] [Abstract][Full Text] [Related]
15. MO-A-BRB-02: Facts and Fiction of Flattening Filter Free (FF-FFF) X-Rays Beams.
Ting J
Med Phys; 2012 Jun; 39(6Part20):3861-3862. PubMed ID: 28517518
[TBL] [Abstract][Full Text] [Related]
16. Intensity modulated radiation therapy with irregular multileaf collimated field: a dosimetric study on the penumbra region with different leaf stepping patterns.
Chow JC; Grigorov GN; Jiang R
Med Phys; 2006 Dec; 33(12):4606-13. PubMed ID: 17278813
[TBL] [Abstract][Full Text] [Related]
17. SU-E-T-411: Dosimetric Comparison Between Two Multileaf Collimator Systems for Stereotactic Radiosurgery and Radiotherapy.
Asnaashari K; Chow J; Heydarian M
Med Phys; 2012 Jun; 39(6Part16):3799. PubMed ID: 28517206
[TBL] [Abstract][Full Text] [Related]
18. Analysis of small field percent depth dose and profiles: Comparison of measurements with various detectors and effects of detector orientation with different jaw settings.
Godson HF; Ravikumar M; Sathiyan S; Ganesh KM; Ponmalar YR; Varatharaj C
J Med Phys; 2016; 41(1):12-20. PubMed ID: 27051165
[TBL] [Abstract][Full Text] [Related]
19. Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator.
Klüter S; Sroka-Perez G; Schubert K; Debus J
Phys Med Biol; 2011 Jan; 56(2):N29-37. PubMed ID: 21178240
[TBL] [Abstract][Full Text] [Related]
20. Monte Carlo implementation, validation, and characterization of a 120 leaf MLC.
Fix MK; Volken W; Frei D; Frauchiger D; Born EJ; Manser P
Med Phys; 2011 Oct; 38(10):5311-20. PubMed ID: 21992349
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]