BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 19895052)

  • 1. Velocity map imaging using an in-vacuum pixel detector.
    Gademann G; Huismans Y; Gijsbertsen A; Jungmann J; Visschers J; Vrakking MJ
    Rev Sci Instrum; 2009 Oct; 80(10):103105. PubMed ID: 19895052
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new imaging method for understanding chemical dynamics: efficient slice imaging using an in-vacuum pixel detector.
    Jungmann JH; Gijsbertsen A; Visser J; Visschers J; Heeren RM; Vrakking MJ
    Rev Sci Instrum; 2010 Oct; 81(10):103112. PubMed ID: 21034080
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 14C autoradiography with an energy-sensitive silicon pixel detector.
    Esposito M; Mettivier G; Russo P
    Phys Med Biol; 2011 Apr; 56(7):1947-65. PubMed ID: 21364264
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A pixel detector-based single photon-counting system as fast spectrometer for diagnostic X-ray beams.
    Carpentieri C; Bisogni MG; Del Guerra A; Delogu P; Fantacci ME; Fogli J; Marchi A; Marzulli V; Rosso V; Stefanini A; Tofani A
    Radiat Prot Dosimetry; 2008; 129(1-3):119-22. PubMed ID: 18487616
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 18F-FDG positron autoradiography with a particle counting silicon pixel detector.
    Russo P; Lauria A; Mettivier G; Montesi MC; Marotta M; Aloj L; Lastoria S
    Phys Med Biol; 2008 Nov; 53(21):6227-43. PubMed ID: 18923198
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Imaging performance of the hybrid pixel detectors XPAD3-S.
    Brunner FC; Clemens JC; Hemmer C; Morel C
    Phys Med Biol; 2009 Mar; 54(6):1773-89. PubMed ID: 19258683
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electron imaging with Medipix2 hybrid pixel detector.
    McMullan G; Cattermole DM; Chen S; Henderson R; Llopart X; Summerfield C; Tlustos L; Faruqi AR
    Ultramicroscopy; 2007; 107(4-5):401-13. PubMed ID: 17140733
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microscope mode secondary ion mass spectrometry imaging with a Timepix detector.
    Kiss A; Jungmann JH; Smith DF; Heeren RM
    Rev Sci Instrum; 2013 Jan; 84(1):013704. PubMed ID: 23387656
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-energy X-ray diffraction using the Pixium 4700 flat-panel detector.
    Daniels JE; Drakopoulos M
    J Synchrotron Radiat; 2009 Jul; 16(Pt 4):463-8. PubMed ID: 19535858
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Silicon drift and pixel devices for X-ray imaging and spectroscopy.
    Lutz G
    J Synchrotron Radiat; 2006 Mar; 13(Pt 2):99-109. PubMed ID: 16495610
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection systems for mass spectrometry imaging: a perspective on novel developments with a focus on active pixel detectors.
    Jungmann JH; Heeren RM
    Rapid Commun Mass Spectrom; 2013 Jan; 27(1):1-23. PubMed ID: 23239313
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of a Timepix detector for use in SEM acceleration voltage range.
    Denisov N; Jannis D; Orekhov A; Müller-Caspary K; Verbeeck J
    Ultramicroscopy; 2023 Nov; 253():113777. PubMed ID: 37336162
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterization of an in-vacuum PILATUS 1M detector.
    Wernecke J; Gollwitzer C; Müller P; Krumrey M
    J Synchrotron Radiat; 2014 May; 21(Pt 3):529-36. PubMed ID: 24763642
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Energy-sensitive cryogenic detectors for high-mass biomolecule mass spectrometry.
    Frank M; Labov SE; Westmacott G; Benner WH
    Mass Spectrom Rev; 1999; 18(3-4):155-86. PubMed ID: 10568040
    [TBL] [Abstract][Full Text] [Related]  

  • 15. First images of a digital autoradiography system based on a Medipix2 hybrid silicon pixel detector.
    Mettivier G; Montesi MC; Russo P
    Phys Med Biol; 2003 Jun; 48(12):N173-81. PubMed ID: 12870591
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Advanced mercuric iodide detectors for X-ray microanalysis.
    Warburton WK; Iwanczyk JS
    Scanning Microsc Suppl; 1987; 1():135-50. PubMed ID: 3481104
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A photoelectron-photoion coincidence imaging apparatus for femtosecond time-resolved molecular dynamics with electron time-of-flight resolution of sigma=18 ps and energy resolution Delta E/E=3.5%.
    Vredenborg A; Roeterdink WG; Janssen MH
    Rev Sci Instrum; 2008 Jun; 79(6):063108. PubMed ID: 18601398
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Active pixel sensor array as a detector for electron microscopy.
    Milazzo AC; Leblanc P; Duttweiler F; Jin L; Bouwer JC; Peltier S; Ellisman M; Bieser F; Matis HS; Wieman H; Denes P; Kleinfelder S; Xuong NH
    Ultramicroscopy; 2005 Sep; 104(2):152-9. PubMed ID: 15890445
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ion-ion coincidence imaging at high event rate using an in-vacuum pixel detector.
    Long J; Furch FJ; Durá J; Tremsin AS; Vallerga J; Schulz CP; Rouzée A; Vrakking MJJ
    J Chem Phys; 2017 Jul; 147(1):013919. PubMed ID: 28688405
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reconstruction of 2D PET data with Monte Carlo generated system matrix for generalized natural pixels.
    Vandenberghe S; Staelens S; Byrne CL; Soares EJ; Lemahieu I; Glick SJ
    Phys Med Biol; 2006 Jun; 51(12):3105-25. PubMed ID: 16757866
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.