These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 19906377)

  • 1. Novel methods to study functional loading micromechanics at the stem-cement and cement-bone interface in cemented femoral hip replacements.
    Race A; Miller MA; Mann KA
    J Biomech; 2010 Mar; 43(4):788-91. PubMed ID: 19906377
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Functional interface micromechanics of 11 en-bloc retrieved cemented femoral hip replacements.
    Mann KA; Miller MA; Verdonschot N; Izant TH; Race A
    Acta Orthop; 2010 Jun; 81(3):308-17. PubMed ID: 20367421
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses.
    Ramos A; Simões JA
    J Biomech; 2009 Nov; 42(15):2602-10. PubMed ID: 19660758
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Investigation of relative micromotion at the stem-cement interface in total hip replacement.
    Zhang HY; Brown L; Barrans S; Blunt L; Jiang XQ
    Proc Inst Mech Eng H; 2009 Nov; 223(8):955-64. PubMed ID: 20092093
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel test method for evaluation of the abrasive wear behaviour of total hip stems at the interface between implant surface and bone cement.
    Bader R; Steinhauser E; Holzwarth U; Schmitt M; Mittelmeier W
    Proc Inst Mech Eng H; 2004; 218(4):223-30. PubMed ID: 15376724
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Micromechanics of postmortem-retrieved cement-bone interfaces.
    Miller MA; Eberhardt AW; Cleary RJ; Verdonschot N; Mann KA
    J Orthop Res; 2010 Feb; 28(2):170-7. PubMed ID: 19658167
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A numerical study of failure mechanisms in the cemented resurfaced femur: effects of interface characteristics and bone remodelling.
    Pal B; Gupta S; New AM
    Proc Inst Mech Eng H; 2009 May; 223(4):471-84. PubMed ID: 19499837
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Early cement damage around a femoral stem is concentrated at the cement/bone interface.
    Race A; Miller MA; Ayers DC; Mann KA
    J Biomech; 2003 Apr; 36(4):489-96. PubMed ID: 12600339
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro interface and cement mantle analysis of different femur stem designs.
    Gravius S; Wirtz DC; Siebert CH; Andereya S; Mueller-Rath R; Maus U; Mumme T
    J Biomech; 2008; 41(9):2021-8. PubMed ID: 18514207
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Factors affecting cement strains near the tip of a cemented femoral component.
    Estok DM; Orr TE; Harris WH
    J Arthroplasty; 1997 Jan; 12(1):40-8. PubMed ID: 9021500
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enhancement of initial stability of press-fit femoral stems using injectable calcium phosphate cement: an in vitro study in dog bones.
    Ooms EM; Verdonschot N; Wolke JG; Van de Wijdeven W; Willems MM; Schoenmaker MF; Jansen JA
    Biomaterials; 2004 Aug; 25(17):3887-94. PubMed ID: 15020165
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Initial stability of fully and partially cemented femoral stems.
    Claes L; Fiedler S; Ohnmacht M; Duda GN
    Clin Biomech (Bristol, Avon); 2000 Dec; 15(10):750-5. PubMed ID: 11050357
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of femoral neck length, stem size, and body weight on strains in the proximal cement mantle.
    Harrington MA; O'Connor DO; Lozynsky AJ; Kovach I; Harris WH
    J Bone Joint Surg Am; 2002 Apr; 84(4):573-9. PubMed ID: 11940617
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stem surface roughness alters creep induced subsidence and 'taper-lock' in a cemented femoral hip prosthesis.
    Norman TL; Thyagarajan G; Saligrama VC; Gruen TA; Blaha JD
    J Biomech; 2001 Oct; 34(10):1325-33. PubMed ID: 11522312
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of dorsal flanges on fixation of a cemented total hip replacement femoral stem.
    Sangiorgio SN; Ebramzadeh E; Longjohn DB; Dorr LD
    J Bone Joint Surg Am; 2004 Apr; 86(4):813-20. PubMed ID: 15069149
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cement-mantle thickness affects cement strains in total hip replacement.
    Fisher DA; Tsang AC; Paydar N; Milionis S; Turner CH
    J Biomech; 1997; 30(11-12):1173-7. PubMed ID: 9456387
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Application of an amphiphilic bonder in a goat model to increase the femoral cement-bone adhesion in cemented hip arthroplasty].
    Müller-Rath R; Wirtz D; Andereya S; Gravius S; Hermanns-Sachweh B; Marx R; Mumme T
    Z Orthop Unfall; 2007; 145(4):476-82. PubMed ID: 17912668
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of modular head seating on the cement-stem interface strength of femoral prostheses.
    Weiss JM; Novak VP; Belkoff SM
    J Arthroplasty; 1998 Oct; 13(7):799-803. PubMed ID: 9802668
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Interface micromechanics of transverse sections from retrieved cemented hip reconstructions: an experimental and finite element comparison.
    Waanders D; Janssen D; Berahmani S; Miller MA; Mann KA; Verdonschot N
    J Mater Sci Mater Med; 2012 Aug; 23(8):2023-35. PubMed ID: 22678039
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.