163 related articles for article (PubMed ID: 19918219)
1. Rapid fabrication of custom patient biopsy guides.
Rajon DA; Bova FJ; Chi YY; Friedman WA
J Appl Clin Med Phys; 2009 Sep; 10(4):260-272. PubMed ID: 19918219
[TBL] [Abstract][Full Text] [Related]
2. An investigation of the potential of rapid prototyping technology for image guided surgery.
Rajon DA; Bova FJ; Bhasin RR; Friedman WA
J Appl Clin Med Phys; 2006 Nov; 7(4):81-98. PubMed ID: 17533357
[TBL] [Abstract][Full Text] [Related]
3. Image-guided frameless stereotactic needle biopsy in awake patients without the use of rigid head fixation.
Amin DV; Lozanne K; Parry PV; Engh JA; Seelman K; Mintz A
J Neurosurg; 2011 May; 114(5):1414-20. PubMed ID: 20722608
[TBL] [Abstract][Full Text] [Related]
4. Frame-based stereotactic biopsy remains an important diagnostic tool with distinct advantages over frameless stereotactic biopsy.
Smith JS; Quiñones-Hinojosa A; Barbaro NM; McDermott MW
J Neurooncol; 2005 Jun; 73(2):173-9. PubMed ID: 15981109
[TBL] [Abstract][Full Text] [Related]
5. Assessment of image guided accuracy in a skull model: comparison of frameless stereotaxy techniques vs. frame-based localization.
Quiñones-Hinojosa A; Ware ML; Sanai N; McDermott MW
J Neurooncol; 2006 Jan; 76(1):65-70. PubMed ID: 16132501
[TBL] [Abstract][Full Text] [Related]
6. Blurring the boundaries between frame-based and frameless stereotaxy: feasibility study for brain biopsies performed with the use of a head-mounted robot.
Grimm F; Naros G; Gutenberg A; Keric N; Giese A; Gharabaghi A
J Neurosurg; 2015 Sep; 123(3):737-42. PubMed ID: 26067616
[TBL] [Abstract][Full Text] [Related]
7. Remotely-controlled approach for stereotactic neurobiopsy.
Liu H; Hall WA; Truwit CL
Comput Aided Surg; 2002; 7(4):237-47. PubMed ID: 12454894
[TBL] [Abstract][Full Text] [Related]
8. Tactics: an open-source platform for planning, simulating and validating stereotactic surgery.
Adair DSP; Gomes KS; Kiss ZHT; Gobbi DG; Starreveld YP
Comput Assist Surg (Abingdon); 2020 Dec; 25(1):1-14. PubMed ID: 32401082
[TBL] [Abstract][Full Text] [Related]
9. Use of a volumetric target for image-guided surgery.
Gildenberg PL; Labuz J
Neurosurgery; 2006 Sep; 59(3):651-9; discussion 651-9. PubMed ID: 16955047
[TBL] [Abstract][Full Text] [Related]
10. A novel re-attachable stereotactic frame for MRI-guided neuronavigation and its validation in a large animal and human cadaver model.
Edwards CA; Rusheen AE; Oh Y; Paek SB; Jacobs J; Lee KH; Dennis KD; Bennet KE; Kouzani AZ; Lee KH; Goerss SJ
J Neural Eng; 2018 Dec; 15(6):066003. PubMed ID: 30124202
[TBL] [Abstract][Full Text] [Related]
11. Technical description, phantom accuracy, and clinical feasibility for fiducial-free frameless real-time image-guided spinal radiosurgery.
Muacevic A; Staehler M; Drexler C; Wowra B; Reiser M; Tonn JC
J Neurosurg Spine; 2006 Oct; 5(4):303-12. PubMed ID: 17048766
[TBL] [Abstract][Full Text] [Related]
12. Nexframe frameless stereotaxy with multitract microrecording: accuracy evaluated by frame-based stereotactic X-ray.
Fukaya C; Sumi K; Otaka T; Obuchi T; Kano T; Kobayashi K; Oshima H; Yamamoto T; Katayama Y
Stereotact Funct Neurosurg; 2010; 88(3):163-8. PubMed ID: 20431327
[TBL] [Abstract][Full Text] [Related]
13. A needle guidance system for biopsy and therapy using two-dimensional ultrasound.
Bluvol N; Sheikh A; Kornecki A; Fernandez Ddel R; Downey D; Fenster A
Med Phys; 2008 Feb; 35(2):617-28. PubMed ID: 18383683
[TBL] [Abstract][Full Text] [Related]
14. Accuracy of Novel Computed Tomography-Guided Frameless Stereotactic Drilling and Catheter System in Human Cadavers.
Sankey EW; Butler E; Sampson JH
World Neurosurg; 2017 Oct; 106():757-763. PubMed ID: 28754645
[TBL] [Abstract][Full Text] [Related]
15. Clinical validation of true frameless stereotactic biopsy: analysis of the first 125 consecutive cases.
Paleologos TS; Dorward NL; Wadley JP; Thomas DG
Neurosurgery; 2001 Oct; 49(4):830-5; discussion 835-7. PubMed ID: 11564243
[TBL] [Abstract][Full Text] [Related]
16. Integration of multimodality imaging and surgical navigation in the management of patients with refractory epilepsy. A pilot study using a new minimally invasive reference and head-fixation system.
Ortler M; Trinka E; Dobesberger J; Bauer R; Unterhofer C; Twerdy K; Walser G; Unterberger I; Donnemiller E; Gotwald T; Widmann G; Bale R
Acta Neurochir (Wien); 2010 Feb; 152(2):365-78. PubMed ID: 19960357
[TBL] [Abstract][Full Text] [Related]
17. Accuracy and clinical use of a novel aiming device for frameless stereotactic brain biopsy.
Widmann G; Eisner W; Kovacs P; Fiegele T; Ortler M; Lang TB; Stoffner R; Bale R
Minim Invasive Neurosurg; 2008 Dec; 51(6):361-9. PubMed ID: 19061150
[TBL] [Abstract][Full Text] [Related]
18. Frameless stereotactic targeting devices: technical features, targeting errors and clinical results.
Widmann G; Schullian P; Ortler M; Bale R
Int J Med Robot; 2012 Mar; 8(1):1-16. PubMed ID: 22076960
[TBL] [Abstract][Full Text] [Related]
19. The impact of the reference imaging modality, registration method and intraoperative flat-panel computed tomography on the accuracy of the ROSA® stereotactic robot.
Lefranc M; Capel C; Pruvot AS; Fichten A; Desenclos C; Toussaint P; Le Gars D; Peltier J
Stereotact Funct Neurosurg; 2014; 92(4):242-50. PubMed ID: 25170634
[TBL] [Abstract][Full Text] [Related]
20. Impact of a self-developed planning and self-constructed navigation system on skull base surgery: 10 years experience.
Caversaccio M; Langlotz F; Nolte LP; Häusler R
Acta Otolaryngol; 2007 Apr; 127(4):403-7. PubMed ID: 17453461
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]