BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 19923105)

  • 1. Effects of EDTA on routine and specialized coagulation testing and an easy method to distinguish EDTA-treated from citrated plasma samples.
    Crist RA; Gibbs K; Rodgers GM; Smock KJ
    Lab Hematol; 2009; 15(4):45-8. PubMed ID: 19923105
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of EDTA hematology tubes for collection of blood samples for tests of secondary hemostasis in dogs.
    Cerón JJ; Carli E; Tasca S; Martinez-Subiela S; Caldin M
    Am J Vet Res; 2008 Sep; 69(9):1141-7. PubMed ID: 18764684
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Right or wrong sample received for coagulation testing? Tentative algorithms for detection of an incorrect type of sample.
    Lippi G; Salvagno GL; Adcock DM; Gelati M; Guidi GC; Favaloro EJ
    Int J Lab Hematol; 2010 Feb; 32(1 Pt 2):132-8. PubMed ID: 19220524
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sodium citrate blood contamination by K2 -ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation testing.
    Lima-Oliveira G; Salvagno GL; Danese E; Favaloro EJ; Guidi GC; Lippi G
    Int J Lab Hematol; 2015 Jun; 37(3):403-9. PubMed ID: 25308126
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Complement activation in citrate plasma--inhibitory effect of anticoagulants on serum complement activation].
    Kobayashi E; Kitano E; Kondo H; Kitamura H
    Rinsho Byori; 1999 Feb; 47(2):160-4. PubMed ID: 10097633
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants.
    Horsti J
    Haematologica; 2001 Aug; 86(8):851-5. PubMed ID: 11522542
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Discard tubes are not necessary when drawing samples for specialized coagulation testing.
    Smock KJ; Crist RA; Hansen SJ; Rodgers GM; Lehman CM
    Blood Coagul Fibrinolysis; 2010 Apr; 21(3):279-82. PubMed ID: 20182348
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of anticoagulants on the activity of gelatinases.
    Castellazzi M; Tamborino C; Fainardi E; Manfrinato MC; Granieri E; Dallocchio F; Bellini T
    Clin Biochem; 2007 Nov; 40(16-17):1272-6. PubMed ID: 17904541
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effects of different anticoagulants on routine canine plasma biochemistry.
    Cerón JJ; Martínez-Subiela S; Hennemann C; Tecles F
    Vet J; 2004 May; 167(3):294-301. PubMed ID: 15080879
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analogues of ethylenediaminetetraacetic acid and sodium fluoride as anticoagulants.
    Narita M; Hino M; Takubo T; Tatsumi N
    Osaka City Med J; 2000 Jun; 46(1):71-87. PubMed ID: 10983468
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of samples obtained from 3.2% sodium citrate glass and two 3.2% sodium citrate plastic blood collection tubes used in coagulation testing.
    Gosselin RC; Janatpour K; Larkin EC; Lee YP; Owings JT
    Am J Clin Pathol; 2004 Dec; 122(6):843-8. PubMed ID: 15539376
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of citrate concentration in specimen collection tubes on the International Normalized Ratio.
    Danielson CF; Davis K; Jones G; Benson J; Arney K; Martin J
    Arch Pathol Lab Med; 1997 Sep; 121(9):956-9. PubMed ID: 9302927
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of Freeze-Thaw Times on Screening Coagulation Tests and Factors VIII and IX Activities in Citrate-Anticoagulated Plasma at -20°C and -80°C.
    Feng G; Zhao Y; Zhang J; Feng L
    Clin Lab; 2018 Sep; 64(9):1439-1444. PubMed ID: 30274007
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The platelet count in EDTA-anticoagulated blood from patients with thrombocytopenia may be underestimated when measured in routine laboratories.
    Podda GM; Pugliano M; Femia EA; Mezzasoma AM; Gresele P; Carpani G; Cattaneo M
    Am J Hematol; 2012 Jul; 87(7):727-8. PubMed ID: 22674424
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Collection of blood specimens by venipuncture for plasma-based coagulation assays: necessity of a discard tube.
    Raijmakers MT; Menting CH; Vader HL; van der Graaf F
    Am J Clin Pathol; 2010 Feb; 133(2):331-5. PubMed ID: 20093244
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of erythrocyte sedimentation rates of bloods anticoagulated with trisodium citrate and EDTA among TB presumptive patients at the University of Gondar comprehensive specialized hospital, northwest Ethiopia.
    Getaneh Z; Ayelgn F; Asemahegn G; Geleta H; Yalew A; Melak T
    BMC Res Notes; 2020 Feb; 13(1):113. PubMed ID: 32103778
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of hemostatic factors in EDTA plasma.
    Green D; McMahon B; Foiles N; Tian L
    Am J Clin Pathol; 2008 Nov; 130(5):811-5. PubMed ID: 18854275
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stability of coagulation assays performed in plasma from citrated whole blood transported at ambient temperature.
    Zürcher M; Sulzer I; Barizzi G; Lämmle B; Alberio L
    Thromb Haemost; 2008 Feb; 99(2):416-26. PubMed ID: 18278194
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Peptidomic analysis of human blood specimens: comparison between plasma specimens and serum by differential peptide display.
    Tammen H; Schulte I; Hess R; Menzel C; Kellmann M; Mohring T; Schulz-Knappe P
    Proteomics; 2005 Aug; 5(13):3414-22. PubMed ID: 16038021
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pre-instrumental variables in coagulation testing.
    Koepke JA; Rodgers JL; Ollivier MJ
    Am J Clin Pathol; 1975 Nov; 64(5):591-6. PubMed ID: 1190120
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.