These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
1086 related articles for article (PubMed ID: 19923511)
1. A visual stethoscope to detect the position of the tracheal tube. Kato H; Suzuki A; Nakajima Y; Makino H; Sanjo Y; Nakai T; Shiraishi Y; Katoh T; Sato S Anesth Analg; 2009 Dec; 109(6):1836-42. PubMed ID: 19923511 [TBL] [Abstract][Full Text] [Related]
2. Bronchial intubation could be detected by the visual stethoscope techniques in pediatric patients. Kimura T; Suzuki A; Mimuro S; Makino H; Sato S Paediatr Anaesth; 2012 Dec; 22(12):1185-90. PubMed ID: 22928677 [TBL] [Abstract][Full Text] [Related]
3. Unrecognized bronchial intubation associated with the uncuffed pediatric tracheal tube with bilateral Murphy eyes. Sugiyama K; Manabe Y; Kohjitani A Paediatr Anaesth; 2012 Dec; 22(12):1191-6. PubMed ID: 22913578 [TBL] [Abstract][Full Text] [Related]
4. A comparative study of endotracheal tube positioning methods in children: safety from neck movement. Yoo SY; Kim JH; Han SH; Oh AY Anesth Analg; 2007 Sep; 105(3):620-5. PubMed ID: 17717214 [TBL] [Abstract][Full Text] [Related]
5. Does the Murphy eye reduce the reliability of chest auscultation in detecting endobronchial intubation? Sugiyama K; Yokoyama K; Satoh K; Nishihara M; Yoshitomi T Anesth Analg; 1999 Jun; 88(6):1380-3. PubMed ID: 10357348 [TBL] [Abstract][Full Text] [Related]
6. Identification of endotracheal tube malpositions using computerized analysis of breath sounds via electronic stethoscopes. O'Connor CJ; Mansy H; Balk RA; Tuman KJ; Sandler RH Anesth Analg; 2005 Sep; 101(3):735-739. PubMed ID: 16115984 [TBL] [Abstract][Full Text] [Related]
7. [Troubled endotracheal intubation: an adult case of anomalous tracheal bronchus]. Tomoda M; Ueda W; Hasegawa T; Hirakawa M Masui; 1992 Jun; 41(6):984-7. PubMed ID: 1613961 [TBL] [Abstract][Full Text] [Related]
8. [Accidental left bronchial intubation with Parker Flex-Tip Tube]. Kitamura S; Kawano T; Yokoyama M Masui; 2013 Jun; 62(6):678-81. PubMed ID: 23814990 [TBL] [Abstract][Full Text] [Related]
9. Use of the Rapiscope vs chest auscultation for detection of accidental bronchial intubation in non-obese patients undergoing laparoscopic cholecystectomy. Ezri T; Khazin V; Szmuk P; Medalion B; Shechter P; Priel I; Loberboim M; Weinbroum AA J Clin Anesth; 2006 Mar; 18(2):118-23. PubMed ID: 16563329 [TBL] [Abstract][Full Text] [Related]
10. Tracheal shortening during laparoscopic gynecologic surgery. Kim JH; Hong DM; Oh AY; Han SH Acta Anaesthesiol Scand; 2007 Feb; 51(2):235-8. PubMed ID: 17181537 [TBL] [Abstract][Full Text] [Related]
11. The impact of head position on the cuff and tube tip position of preformed oral tracheal tubes in young children. Jordi Ritz EM; Von Ungern-Sternberg BS; Keller K; Frei FJ; Erb TO Anaesthesia; 2008 Jun; 63(6):604-9. PubMed ID: 18477271 [TBL] [Abstract][Full Text] [Related]
13. Tracheal tube fixation: the effect on depth of insertion of midline fixation compared to the angle of the mouth. Sharma K; Varshney M; Kumar R Anaesthesia; 2009 Apr; 64(4):383-6. PubMed ID: 19317702 [TBL] [Abstract][Full Text] [Related]
14. [Selective right bronchial intubation using tracheal tubes under fibroscopic guidance]. Correa J; Litvan H; Casas JI; Moreno M; Villar-Landeira JM Rev Esp Anestesiol Reanim; 1992; 39(2):113-6. PubMed ID: 1594778 [TBL] [Abstract][Full Text] [Related]
15. Bedside prediction of airway length in adults and children. Lee BJ; Yi JW; Chung JY; Kim DO; Kang JM Anesthesiology; 2009 Sep; 111(3):556-60. PubMed ID: 19672184 [TBL] [Abstract][Full Text] [Related]
16. Comparison of neural network predictors in the classification of tracheal-bronchial breath sounds by respiratory auscultation. Folland R; Hines E; Dutta R; Boilot P; Morgan D Artif Intell Med; 2004 Jul; 31(3):211-20. PubMed ID: 15302087 [TBL] [Abstract][Full Text] [Related]
17. Continuous monitoring of dynamic pulmonary compliance enables detection of endobronchial intubation in infants and children. Mahajan A; Hoftman N; Hsu A; Schroeder R; Wald S Anesth Analg; 2007 Jul; 105(1):51-6. PubMed ID: 17578956 [TBL] [Abstract][Full Text] [Related]
18. Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery? de Bellis M; Accardo R; Di Maio M; La Manna C; Rossi GB; Pace MC; Romano V; Rocco G Eur J Cardiothorac Surg; 2011 Oct; 40(4):912-6. PubMed ID: 21802958 [TBL] [Abstract][Full Text] [Related]
19. Placement of the Univent tube without fiberoptic bronchoscope assistance. Weng H; Xu ZY; Liu J; Ma D; Liu DS Anesth Analg; 2010 Feb; 110(2):508-14. PubMed ID: 19933530 [TBL] [Abstract][Full Text] [Related]
20. The displacement of the tracheal tube during robot-assisted radical prostatectomy. Chang CH; Lee HK; Nam SH Eur J Anaesthesiol; 2010 May; 27(5):478-80. PubMed ID: 19918180 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]