133 related articles for article (PubMed ID: 19923685)
1. Measurements of the modulation transfer function, normalized noise power spectrum and detective quantum efficiency for two flat panel detectors: a fluoroscopic and a cone beam computer tomography flat panel detectors.
Benítez RB; Ning R; Conover D; Liu S
J Xray Sci Technol; 2009; 17(4):279-93. PubMed ID: 19923685
[TBL] [Abstract][Full Text] [Related]
2. Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation.
Ning R; Chen B; Yu R; Conover D; Tang X; Ning Y
IEEE Trans Med Imaging; 2000 Sep; 19(9):949-63. PubMed ID: 11127608
[TBL] [Abstract][Full Text] [Related]
3. Imaging performance of the hybrid pixel detectors XPAD3-S.
Brunner FC; Clemens JC; Hemmer C; Morel C
Phys Med Biol; 2009 Mar; 54(6):1773-89. PubMed ID: 19258683
[TBL] [Abstract][Full Text] [Related]
4. Technical advances of interventional fluoroscopy and flat panel image receptor.
Lin PJ
Health Phys; 2008 Nov; 95(5):650-7. PubMed ID: 18849699
[TBL] [Abstract][Full Text] [Related]
5. The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography.
Cowen AR; Davies AG; Sivananthan MU
Clin Radiol; 2008 Oct; 63(10):1073-85. PubMed ID: 18774353
[TBL] [Abstract][Full Text] [Related]
6. Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: visibility of simulated microcalcifications.
Shen Y; Zhong Y; Lai CJ; Wang T; Shaw CC
Med Phys; 2013 Oct; 40(10):101915. PubMed ID: 24089917
[TBL] [Abstract][Full Text] [Related]
7. Performance of electronic portal imaging devices (EPIDs) used in radiotherapy: image quality and dose measurements.
Cremers F; Frenzel T; Kausch C; Albers D; Schönborn T; Schmidt R
Med Phys; 2004 May; 31(5):985-96. PubMed ID: 15191282
[TBL] [Abstract][Full Text] [Related]
8. [Flat-panel detectors in X-ray systems].
Spahn M; Heer V; Freytag R
Radiologe; 2003 May; 43(5):340-50. PubMed ID: 12764582
[TBL] [Abstract][Full Text] [Related]
9. Performance of a 41 x 41 cm2 amorphous silicon flat panel x-ray detector designed for angiographic and R&F imaging applications.
Granfors PR; Aufrichtig R; Possin GE; Giambattista BW; Huang ZS; Liu J; Ma B
Med Phys; 2003 Oct; 30(10):2715-26. PubMed ID: 14596310
[TBL] [Abstract][Full Text] [Related]
10. Imaging characteristics evaluation of a digital radiography system.
Moro L; Pannella A; Bassetti C; Fantinato D; Baldi M; Bertoli G
Radiol Med; 2003; 106(1-2):94-102. PubMed ID: 12951556
[TBL] [Abstract][Full Text] [Related]
11. A comparison between objective and subjective image quality measurements for a full field digital mammography system.
Marshall NW
Phys Med Biol; 2006 May; 51(10):2441-63. PubMed ID: 16675862
[TBL] [Abstract][Full Text] [Related]
12. A spatio-temporal detective quantum efficiency and its application to fluoroscopic systems.
Friedman SN; Cunningham IA
Med Phys; 2010 Nov; 37(11):6061-9. PubMed ID: 21158318
[TBL] [Abstract][Full Text] [Related]
13. Quality control measurements for digital x-ray detectors.
Marshall NW; Mackenzie A; Honey ID
Phys Med Biol; 2011 Feb; 56(4):979-99. PubMed ID: 21248386
[TBL] [Abstract][Full Text] [Related]
14. NPS characterization and evaluation of a cone beam CT breast imaging system.
Benítez RB; Ning R; Conover D; Liu S
J Xray Sci Technol; 2009; 17(1):17-40. PubMed ID: 19644211
[TBL] [Abstract][Full Text] [Related]
15. Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier.
Ducote JL; Xu T; Molloi S
Phys Med Biol; 2007 Jan; 52(1):183-96. PubMed ID: 17183135
[TBL] [Abstract][Full Text] [Related]
16. An examination of automatic exposure control regimes for two digital radiography systems.
Marshall NW
Phys Med Biol; 2009 Aug; 54(15):4645-70. PubMed ID: 19590115
[TBL] [Abstract][Full Text] [Related]
17. [Hologic's Flat-Panel Detector].
Ogata Y; Matsumoto M; Suekane K
Igaku Butsuri; 2002; 22(4):264-75. PubMed ID: 12766272
[TBL] [Abstract][Full Text] [Related]
18. Physical characterization of a high-resolution CCD detector for mammography.
Elbakri IA; Tesic MM; Xiong Q
Phys Med Biol; 2007 Apr; 52(8):2171-83. PubMed ID: 17404462
[TBL] [Abstract][Full Text] [Related]
19. Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy.
Ding GX; Duggan DM; Coffey CW
Phys Med Biol; 2007 Mar; 52(6):1595-615. PubMed ID: 17327651
[TBL] [Abstract][Full Text] [Related]
20. An experimental comparison of flat-panel detector performance for direct and indirect systems (initial experiences and physical evaluation).
Gomi T; Koshida K; Miyati T; Miyagawa J; Hirano H
J Digit Imaging; 2006 Dec; 19(4):362-70. PubMed ID: 16763929
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]