BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 19924433)

  • 1. Bipolar thermofusion vessel sealing system (TVS) versus conventional vessel ligation (CVL) in thyroid surgery--results of a prospective study.
    Alesina PF; Rolfs T; Walz MK
    Langenbecks Arch Surg; 2010 Feb; 395(2):115-9. PubMed ID: 19924433
    [TBL] [Abstract][Full Text] [Related]  

  • 2. LigaSure vs clamp-and-tie technique to achieve hemostasis in total thyroidectomy for benign multinodular goiter: a prospective randomized study.
    Saint Marc O; Cogliandolo A; Piquard A; Famà F; Pidoto RR
    Arch Surg; 2007 Feb; 142(2):150-6; discussion 157. PubMed ID: 17309966
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative analysis between a bipolar vessel sealing and cutting device and the tie and suture technique in thyroidectomy: A randomized clinical trial.
    Chavez KV; Barajas EM; Ramírez J; Pantoja JP; Sierra M; Velázquez-Fernandez D; Herrera MF
    Surgery; 2017 Feb; 161(2):477-484. PubMed ID: 27614416
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of two methods of hemostasis in thyroidectomy.
    McNally MM; Agle SC; Williams RF; Pofahl WE
    Am Surg; 2009 Nov; 75(11):1073-6. PubMed ID: 19927508
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The safety of the Harmonic® FOCUS in open thyroidectomy: a prospective, randomized study comparing the Harmonic® FOCUS and traditional suture ligation (knot and tie) technique.
    Zanghì A; Cavallaro A; Di Vita M; Cardì F; Di Mattia P; Piccolo G; Barbera G; Urso M; Cappellani A
    Int J Surg; 2014; 12 Suppl 1():S132-5. PubMed ID: 24862674
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A safety-based comparison of pure LigaSure use and LigaSure-tie technique in total thyroidectomy.
    Pergel A; Yucel AF; Aydin I; Sahin DA; Aras S; Kulacoglu H
    Chirurgia (Bucur); 2014; 109(1):60-5. PubMed ID: 24524472
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prospective randomized trial of ligasure versus harmonic hemostasis technique in thyroidectomy.
    Rahbari R; Mathur A; Kitano M; Guerrero M; Shen WT; Duh QY; Clark OH; Kebebew E
    Ann Surg Oncol; 2011 Apr; 18(4):1023-7. PubMed ID: 21072688
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Randomized controlled trial on vessel sealing in thyroid surgery].
    Minner S; Rödiger H; Mansmann U; Böhm B
    Zentralbl Chir; 2007 Oct; 132(5):446-50. PubMed ID: 17907089
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparison of conventional technique, Ligasure Precise and Harmonic Focus in total thyroidectomy].
    Di Rienzo RM; Bove A; Bongarzoni G; Palone G; Corradetti L; Corbellini L
    G Chir; 2010; 31(6-7):296-8. PubMed ID: 20646375
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safety and Cost-Effectiveness in Thyroidectomy Using the HARMONIC Scalpel Compared to Traditional Hemostasis: A Controlled Clinical Assay.
    Basurto-Kuba EOP; Robles-Estrada M; Hurtado-López LM; E Oca-Duran EDM; Campos-Castillo C; Zaldivar-Ramirez FR; Pulido-Cejudo A
    Surg Technol Int; 2017 Jul; 30():141-147. PubMed ID: 28537355
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electrothermal bipolar vessel sealing system is a safe and time-saving alternative to classic suture ligation in total thyroidectomy.
    Manouras A; Lagoudianakis EE; Antonakis PT; Filippakis GM; Markogiannakis H; Kekis PB
    Head Neck; 2005 Nov; 27(11):959-62. PubMed ID: 16134183
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sutureless total thyroidectomy: a safe and cost-effective alternative.
    Chang LY; O'Neill C; Suliburk J; Sidhu S; Delbridge L; Sywak M
    ANZ J Surg; 2011; 81(7-8):510-4. PubMed ID: 22295369
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Novel hemostatic devices in thyroid surgery: electrothermal bipolar vessel sealing system and harmonic scalpel.
    Manouras A; Markogiannakis HE; Kekis PB; Lagoudianakis EE; Fleming B
    Expert Rev Med Devices; 2008 Jul; 5(4):447-66. PubMed ID: 18573045
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of Surgical Complications Rates Between LigaSure Small Jaw and Clamp-and-Tie Hemostatic Technique in 1,000 Neuro-Monitored Thyroidectomies.
    Liu CH; Wang CC; Wu CW; Lin YC; Lu IC; Chang PY; Lien CF; Wang CC; Hwang TZ; Huang TY; Chiang FY
    Front Endocrinol (Lausanne); 2021; 12():638608. PubMed ID: 33897619
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery.
    Siperstein AE; Berber E; Morkoyun E
    Arch Surg; 2002 Feb; 137(2):137-42. PubMed ID: 11822946
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Major complications in thyroid surgery: utility of bipolar vessel sealing (Ligasure Precise).
    Parmeggiani U; Avenia N; De Falco M; Parmeggiani D; Pisaniello D; d'Ajello M; Monacelli M; Calzolari F; Sanguinetti A; Sperlongano P
    G Chir; 2005 Oct; 26(10):387-94. PubMed ID: 16371192
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thyroid surgery: use of the LigaSure Vessel Sealing System versus conventional knot tying.
    Youssef T; Mahdy T; Farid M; Latif AA
    Int J Surg; 2008 Aug; 6(4):323-7. PubMed ID: 18585113
    [TBL] [Abstract][Full Text] [Related]  

  • 18. LigaSure versus conventional hemostasis in thyroid surgery: prospective randomized controlled trial.
    Singh P; O'Connell D; Langille M; Dziegielewski P; Allegretto M; Harris J
    J Otolaryngol Head Neck Surg; 2010 Aug; 39(4):378-84. PubMed ID: 20643002
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation.
    Manouras A; Markogiannakis H; Koutras AS; Antonakis PT; Drimousis P; Lagoudianakis EE; Kekis P; Genetzakis M; Koutsoumanis K; Bramis I
    Am J Surg; 2008 Jan; 195(1):48-52. PubMed ID: 18082542
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of ultrasound dissection in thyroid surgery.
    Witzel K; von Rahden BH; Stein HJ
    Eur Surg Res; 2009; 43(2):241-4. PubMed ID: 19571545
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.