BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 19924675)

  • 1. Determination of chlorpheniramine in human plasma by HPLC-ESI-MS/MS: application to a dexchlorpheniramine comparative bioavailability study.
    Moreno RA; Oliveira-Silva D; Sverdloff CE; Borges BC; Rebelo Galvinas PA; Astigarraga RB; Borges NC
    Biomed Chromatogr; 2010 Jul; 24(7):774-81. PubMed ID: 19924675
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel and sensitive method for ethinylestradiol quantification in human plasma by high-performance liquid chromatography coupled to atmospheric pressure photoionization (APPI) tandem mass spectrometry: application to a comparative pharmacokinetics study.
    Borges NC; Astigarraga RB; Sverdloff CE; Galvinas PR; da Silva WM; Rezende VM; Moreno RA
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Nov; 877(29):3601-9. PubMed ID: 19773204
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ciprofibrate quantification in human plasma by high-performance liquid chromatography coupled with electrospray tandem mass spectrometry for pharmacokinetic studies.
    Mendes FD; Chen LS; Borges A; Babadópulos T; Ilha JO; Alkharfy KM; Mendes GD; De Nucci G
    J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Aug; 879(24):2361-8. PubMed ID: 21763220
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Budesonide quantification by HPLC coupled to atmospheric pressure photoionization (APPI) tandem mass spectrometry. Application to a comparative systemic bioavailability of two budesonide formulations in healthy volunteers.
    Borges NC; Astigarraga RB; Sverdloff CE; Borges BC; Paiva TR; Galvinas PR; Moreno RA
    J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Feb; 879(3-4):236-42. PubMed ID: 21233029
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bromazepam determination in human plasma by high-performance liquid chromatography coupled to tandem mass spectrometry: a highly sensitive and specific tool for bioequivalence studies.
    Laurito TL; Mendes GD; Santagada V; Caliendo G; de Moraes ME; De Nucci G
    J Mass Spectrom; 2004 Feb; 39(2):168-76. PubMed ID: 14991686
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ticlopidine quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study.
    Borges NC; Mendes GD; Borges A; Oliveira SE; Barrientos-Astigarraga RE; Nucci GD
    J Mass Spectrom; 2004 Dec; 39(12):1562-9. PubMed ID: 15578632
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Chlorpromazine quantification in human plasma by UPLC-electrospray ionization tandem mass spectrometry. Application to a comparative pharmacokinetic study.
    Borges NC; Rezende VM; Santana JM; Moreira RP; Moreira RF; Moreno P; Borges DC; Donato JL; Moreno RA
    J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Dec; 879(31):3728-34. PubMed ID: 22074958
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A fast, sensitive and simple method for mirtazapine quantification in human plasma by HPLC-ESI-MS/MS. Application to a comparative bioavailability study.
    Borges NC; Barrientos-Astigarraga RE; Sverdloff CE; Donato JL; Moreno P; Felix L; Galvinas PA; Moreno RA
    Biomed Chromatogr; 2012 Nov; 26(11):1399-407. PubMed ID: 22345050
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification of cyproheptadine in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry in a bioequivalence study.
    Mendes GD; Arruda A; Chen LS; de Almeida Magalhães JC; Alkharfy KM; De Nucci G
    Biomed Chromatogr; 2012 Jan; 26(1):129-36. PubMed ID: 21432861
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development and validation of a rapid and sensitive LC-ESI-MS/MS method for ondansetron quantification in human plasma and its application in comparative bioavailability study.
    Moreira RF; Salvadori MC; Azevedo CP; Oliveira-Silva D; Borges DC; Moreno RA; Sverdloff CE; Borges NC
    Biomed Chromatogr; 2010 Nov; 24(11):1220-7. PubMed ID: 20954214
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simultaneous determination of dextromethorphan, dextrorphan and doxylamine in human plasma by HPLC coupled to electrospray ionization tandem mass spectrometry: application to a pharmacokinetic study.
    Donato JL; Koizumi F; Pereira AS; Mendes GD; De Nucci G
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Jun; 899():46-56. PubMed ID: 22651995
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nevirapine quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study.
    Laurito TL; Santagada V; Caliendo G; Oliveira CH; Barrientos-Astigarraga RE; De Nucci G
    J Mass Spectrom; 2002 Apr; 37(4):434-41. PubMed ID: 11948850
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of bromazepam in human plasma by high-performance liquid chromatography with electrospray ionization tandem mass spectrometric detection: application to a bioequivalence study.
    Andraus MH; Wong A; Silva OA; Wada CY; Toffleto O; Azevedo CP; Salvadori MC
    J Mass Spectrom; 2004 Nov; 39(11):1348-55. PubMed ID: 15532067
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bioavailability of two oral suspension and two oral tablet formulations of nimesulide 100 mg in healthy Brazilian adult subjects.
    Rigato HM; Borges BC; Sverdloff CE; Moreno RA; Orpineli E; Carter Borges N
    Int J Clin Pharmacol Ther; 2010 Mar; 48(3):233-42. PubMed ID: 20197019
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of nimesulide in human plasma by high-performance liquid chromatography/tandem mass spectrometry. Application to bioequivalence studies.
    Barrientos-Astigarraga RE; Vannuchi YB; Sucupira M; Moreno RA; Muscará MN; De Nucci G
    J Mass Spectrom; 2001 Dec; 36(12):1281-6. PubMed ID: 11754119
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantification of carvedilol in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry: application to bioequivalence study.
    do Carmo Borges NC; Mendes GD; de Oliveira Silva D; Marcondes Rezende V; Barrientos-Astigarraga RE; De Nucci G
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Aug; 822(1-2):253-62. PubMed ID: 16005691
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous quantification of enalapril and enalaprilat in human plasma by high-performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study.
    Lu S; Jiang K; Qin F; Lu X; Li F
    J Pharm Biomed Anal; 2009 Jan; 49(1):163-7. PubMed ID: 19046843
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simple and rapid method determination for metformin in human plasma using high performance liquid chromatography tandem mass spectrometry: application to pharmacokinetic studies.
    Marques MA; Soares Ade S; Pinto OW; Barroso PT; Pinto DP; Ferreira-Filho M; Werneck-Barroso E
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):308-16. PubMed ID: 17331818
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of tegaserod by LC-ESI-MS/MS and its application to a pharmacokinetic study in healthy Chinese volunteers.
    Zou JJ; Bian XJ; Ding L; Zhu YB; Fan HW; Xiao DW
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Jan; 861(1):151-7. PubMed ID: 18069077
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development and validation of a selective and robust LC-MS/MS method for high-throughput quantifying rizatriptan in small plasma samples: application to a clinical pharmacokinetic study.
    Chen Y; Miao H; Lin M; Fan G; Hong Z; Wu H; Wu Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Dec; 844(2):268-77. PubMed ID: 16899417
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.