142 related articles for article (PubMed ID: 19926383)
1. Manual ventilation devices in neonatal resuscitation: tidal volume and positive pressure-provision.
Roehr CC; Kelm M; Fischer HS; Bührer C; Schmalisch G; Proquitté H
Resuscitation; 2010 Feb; 81(2):202-5. PubMed ID: 19926383
[TBL] [Abstract][Full Text] [Related]
2. A comparison of three neonatal resuscitation devices.
Bennett S; Finer NN; Rich W; Vaucher Y
Resuscitation; 2005 Oct; 67(1):113-8. PubMed ID: 16081202
[TBL] [Abstract][Full Text] [Related]
3. Equipment and operator training denote manual ventilation performance in neonatal resuscitation.
Roehr CC; Kelm M; Proquitté H; Schmalisch G
Am J Perinatol; 2010 Oct; 27(9):753-8. PubMed ID: 20458664
[TBL] [Abstract][Full Text] [Related]
4. Leak during manual neonatal ventilation and its effect on the delivered pressures and volumes: an in vitro study.
Hartung JC; te Pas AB; Fischer H; Schmalisch G; Roehr CC
Neonatology; 2012; 102(3):190-5. PubMed ID: 22796898
[TBL] [Abstract][Full Text] [Related]
5. A strategy to optimise the performance of the mouth-to-bag resuscitator using small tidal volumes: effects on lung and gastric ventilation in a bench model of an unprotected airway.
Zecha-Stallinger A; Wenzel V; Wagner-Berger HG; von Goedecke A; Lindner KH; Hörmann C
Resuscitation; 2004 Apr; 61(1):69-74. PubMed ID: 15081184
[TBL] [Abstract][Full Text] [Related]
6. Sustained inflations: comparing three neonatal resuscitation devices.
Klingenberg C; Dawson JA; Gerber A; Kamlin CO; Davis PG; Morley CJ
Neonatology; 2011; 100(1):78-84. PubMed ID: 21273792
[TBL] [Abstract][Full Text] [Related]
7. Comparison of three manual ventilation devices using an intubated mannequin.
Hussey SG; Ryan CA; Murphy BP
Arch Dis Child Fetal Neonatal Ed; 2004 Nov; 89(6):F490-3. PubMed ID: 15499138
[TBL] [Abstract][Full Text] [Related]
8. Providing PEEP during neonatal resuscitation: which device is best?
Dawson JA; Gerber A; Kamlin CO; Davis PG; Morley CJ
J Paediatr Child Health; 2011 Oct; 47(10):698-703. PubMed ID: 21449898
[TBL] [Abstract][Full Text] [Related]
9. [Newborn ventilation: comparison between a T-piece resuscitator and self-infating bags in a neonatal preterm simulator].
Szyld EG; Aguilar AM; Musante GA; Vain NE; Guerrero MN; Serra ME; Prudent LM; Carlo WA
Arch Argent Pediatr; 2012 Apr; 110(2):106-12. PubMed ID: 22451282
[TBL] [Abstract][Full Text] [Related]
10. Variation in inspiratory time and tidal volume with T-piece neonatal resuscitator: association with operator experience and distraction.
McHale S; Thomas M; Hayden E; Bergin K; McCallion N; Molloy EJ
Resuscitation; 2008 Nov; 79(2):230-3. PubMed ID: 18691802
[TBL] [Abstract][Full Text] [Related]
11. Manual neonatal ventilation training: a respiratory function monitor helps to reduce peak inspiratory pressures and tidal volumes during resuscitation.
Kelm M; Dold SK; Hartung J; Breckwoldt J; Schmalisch G; Roehr CC
J Perinat Med; 2012 Sep; 40(5):583-6. PubMed ID: 23120761
[TBL] [Abstract][Full Text] [Related]
12. Responding to compliance changes in a lung model during manual ventilation: perhaps volume, rather than pressure, should be displayed.
Kattwinkel J; Stewart C; Walsh B; Gurka M; Paget-Brown A
Pediatrics; 2009 Mar; 123(3):e465-70. PubMed ID: 19188267
[TBL] [Abstract][Full Text] [Related]
13. The mouth-to-bag resuscitator during standard anaesthesia induction in apnoeic patients.
Herff H; Paal P; Mitterlechner T; von Goedecke A; Stadlbauer KH; Voelckel WG; Zecha-Stallinger A; Wenzel V
Resuscitation; 2009 Oct; 80(10):1142-6. PubMed ID: 19674827
[TBL] [Abstract][Full Text] [Related]
14. An evaluation of peak inspiratory pressure, tidal volume, and ventilatory frequency during ventilation with a neonatal self-inflating bag resuscitator.
Bassani MA; Filho FM; de Carvalho Coppo MR; Martins Marba ST
Respir Care; 2012 Apr; 57(4):525-30. PubMed ID: 22005778
[TBL] [Abstract][Full Text] [Related]
15. Comparison of methods of bag and mask ventilation for neonatal resuscitation.
Finer NN; Rich W; Craft A; Henderson C
Resuscitation; 2001 Jun; 49(3):299-305. PubMed ID: 11719125
[TBL] [Abstract][Full Text] [Related]
16. Use of self-inflating bags for neonatal resuscitation.
Oddie S; Wyllie J; Scally A
Resuscitation; 2005 Oct; 67(1):109-12. PubMed ID: 16150527
[TBL] [Abstract][Full Text] [Related]
17. Neonatal resuscitation 3: manometer use in a model of face mask ventilation.
O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ
Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F397-400. PubMed ID: 15871988
[TBL] [Abstract][Full Text] [Related]
18. Changing gas flow during neonatal resuscitation: a manikin study.
Schilleman K; Schmölzer GM; Kamlin OC; Morley CJ; te Pas AB; Davis PG
Resuscitation; 2011 Jul; 82(7):920-4. PubMed ID: 21444142
[TBL] [Abstract][Full Text] [Related]
19. The self-inflating resuscitation bag delivers high oxygen concentrations when used without a reservoir: implications for neonatal resuscitation.
Johnston KL; Aziz K
Respir Care; 2009 Dec; 54(12):1665-70. PubMed ID: 19961632
[TBL] [Abstract][Full Text] [Related]
20. Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.
O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ
Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F392-6. PubMed ID: 15871989
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]