These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 19926777)

  • 1. Six of eight hemoglobin A1c point-of-care instruments do not meet the general accepted analytical performance criteria.
    Lenters-Westra E; Slingerland RJ
    Clin Chem; 2010 Jan; 56(1):44-52. PubMed ID: 19926777
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Three of 7 hemoglobin A1c point-of-care instruments do not meet generally accepted analytical performance criteria.
    Lenters-Westra E; Slingerland RJ
    Clin Chem; 2014 Aug; 60(8):1062-72. PubMed ID: 24865164
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hemoglobin A1c point-of-care assays; a new world with a lot of consequences!
    Lenters-Westra E; Slingerland RJ
    J Diabetes Sci Technol; 2009 May; 3(3):418-23. PubMed ID: 20144277
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnosing diabetes mellitus: performance of hemoglobin A1c point-of-care instruments in general practice offices.
    Sølvik UØ; Røraas T; Christensen NG; Sandberg S
    Clin Chem; 2013 Dec; 59(12):1790-801. PubMed ID: 23958846
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Utilization of assay performance characteristics to estimate hemoglobin A1c result reliability.
    Woodworth A; Korpi-Steiner N; Miller JJ; Rao LV; Yundt-Pacheco J; Kuchipudi L; Parvin CA; Rhea JM; Molinaro R
    Clin Chem; 2014 Aug; 60(8):1073-9. PubMed ID: 24815907
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of three hemoglobin A1c point-of-care systems for glucose monitoring in patients with diabetes mellitus.
    Torregrosa ME; Molina J; Argente CR; Ena J
    Endocrinol Nutr; 2015 Dec; 62(10):478-84. PubMed ID: 26531840
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy and precision of the Axis-Shield Afinion hemoglobin A1c measurement device.
    Wood JR; Kaminski BM; Kollman C; Beck RW; Hall CA; Yun JP; Cengiz E; Haller MJ; Hassan K; Klingensmith GJ; Tamborlane WV
    J Diabetes Sci Technol; 2012 Mar; 6(2):380-6. PubMed ID: 22538150
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of Four HbA1c Point-of-Care Devices Using International Quality Targets: Are They Fit for the Purpose?
    Lenters-Westra E; English E
    J Diabetes Sci Technol; 2018 Jul; 12(4):762-770. PubMed ID: 29921132
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Are hemoglobin A
    Lenters-Westra E; English E
    Clin Chem Lab Med; 2021 Mar; 59(4):765-774. PubMed ID: 33128524
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemoglobin A1c: assessment of three POC analyzers relative to a central laboratory method.
    Petersen JR; Omoruyi FO; Mohammad AA; Shea TJ; Okorodudu AO; Ju H
    Clin Chim Acta; 2010 Dec; 411(23-24):2062-6. PubMed ID: 20832393
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Selecting an A1C Point-of-Care Instrument.
    Whitley HP; Yong EV; Rasinen C
    Diabetes Spectr; 2015 Aug; 28(3):201-8. PubMed ID: 26300614
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Comparison of HbA1c analyzers: D-10, Variant II Turbo, Cobas Integra 800, and Afinion AS100].
    Lee JY; Hong KS; Cho SE
    Korean J Lab Med; 2010 Aug; 30(4):345-50. PubMed ID: 20805705
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analytical performance of the Axis-Shield Afinion for hemoglobin A1c measurement: impact of lot number.
    Dupuy AM; Badiou S; Elong-Bertard C; Bargnoux AS; Cristol JP
    Clin Lab; 2014; 60(3):369-76. PubMed ID: 24697111
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of Three Hemoglobin A1c Point-of-Care Instruments.
    Criel M; Jonckheere S; Langlois M
    Clin Lab; 2016; 62(3):285-91. PubMed ID: 27156315
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance of point-of-care HbA1c test devices: implications for use in clinical practice - a systematic review and meta-analysis.
    Hirst JA; McLellan JH; Price CP; English E; Feakins BG; Stevens RJ; Farmer AJ
    Clin Chem Lab Med; 2017 Feb; 55(2):167-180. PubMed ID: 27658148
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the ARKRAY HA-8190V instrument for HbA
    van der Hagen EAE; Leppink S; Bokkers K; Siebelder C; Weykamp CW
    Clin Chem Lab Med; 2021 Apr; 59(5):965-970. PubMed ID: 33554536
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improvement in the Quality of HbA1c Determination by Using Commutable Specimens With IFCC-Assigned Values.
    Zhou R; Gao ZQ; Tong Q; Zuo C; Song ZX; Wang W; Wang QT
    Lab Med; 2017 May; 48(2):148-153. PubMed ID: 28371852
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of two HbA1c point-of-care analyzers.
    Sánchez-Mora C; S Rodríguez-Oliva M; Fernández-Riejos P; Mateo J; Polo-Padillo J; Goberna R; Sánchez-Margalet V
    Clin Chem Lab Med; 2011 Apr; 49(4):653-7. PubMed ID: 21323623
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Advances in hemoglobin A1c point of care technology.
    Bode BW; Irvin BR; Pierce JA; Allen M; Clark AL
    J Diabetes Sci Technol; 2007 May; 1(3):405-11. PubMed ID: 19885097
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Status of hemoglobin A1c measurement and goals for improvement: from chaos to order for improving diabetes care.
    Little RR; Rohlfing CL; Sacks DB;
    Clin Chem; 2011 Feb; 57(2):205-14. PubMed ID: 21148304
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.