BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

410 related articles for article (PubMed ID: 19927508)

  • 1. A comparison of two methods of hemostasis in thyroidectomy.
    McNally MM; Agle SC; Williams RF; Pofahl WE
    Am Surg; 2009 Nov; 75(11):1073-6. PubMed ID: 19927508
    [TBL] [Abstract][Full Text] [Related]  

  • 2. LigaSure vs clamp-and-tie technique to achieve hemostasis in total thyroidectomy for benign multinodular goiter: a prospective randomized study.
    Saint Marc O; Cogliandolo A; Piquard A; Famà F; Pidoto RR
    Arch Surg; 2007 Feb; 142(2):150-6; discussion 157. PubMed ID: 17309966
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy.
    Pons Y; Gauthier J; Ukkola-Pons E; Clément P; Roguet E; Poncet JL; Conessa C
    Otolaryngol Head Neck Surg; 2009 Oct; 141(4):496-501. PubMed ID: 19786219
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Thyroid surgery: use of the LigaSure Vessel Sealing System versus conventional knot tying.
    Youssef T; Mahdy T; Farid M; Latif AA
    Int J Surg; 2008 Aug; 6(4):323-7. PubMed ID: 18585113
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Comparison of conventional technique, Ligasure Precise and Harmonic Focus in total thyroidectomy].
    Di Rienzo RM; Bove A; Bongarzoni G; Palone G; Corradetti L; Corbellini L
    G Chir; 2010; 31(6-7):296-8. PubMed ID: 20646375
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Safely increasing the efficiency of thyroidectomy using a new bipolar electrosealing device (LigaSure) versus conventional clamp-and-tie technique.
    Franko J; Kish KJ; Pezzi CM; Pak H; Kukora JS
    Am Surg; 2006 Feb; 72(2):132-6. PubMed ID: 16536242
    [TBL] [Abstract][Full Text] [Related]  

  • 7. LigaSure versus clamp-and-tie in thyroidectomy: a single-center experience.
    Cakabay B; Sevinç MM; Gömceli I; Yenidogan E; Ulkü A; Koç S
    Adv Ther; 2009 Nov; 26(11):1035-41. PubMed ID: 20024679
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Hemostasis and bleeding control in thyroid surgery using electrothermal system (Ligasure): our experience in 317 patients].
    Ashkenazi D; Mazzawi S; Rakover Y
    Harefuah; 2006 Aug; 145(8):561-4, 632, 631. PubMed ID: 16983836
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study.
    Miccoli P; Materazzi G; Miccoli M; Frustaci G; Fosso A; Berti P
    Am J Surg; 2010 Jun; 199(6):736-40. PubMed ID: 20609718
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electrothermal bipolar vessel sealing system is a safe and time-saving alternative to classic suture ligation in total thyroidectomy.
    Manouras A; Lagoudianakis EE; Antonakis PT; Filippakis GM; Markogiannakis H; Kekis PB
    Head Neck; 2005 Nov; 27(11):959-62. PubMed ID: 16134183
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ultrasonic technology facilitates minimal access thyroid surgery.
    Terris DJ; Seybt MW; Gourin CG; Chin E
    Laryngoscope; 2006 Jun; 116(6):851-4. PubMed ID: 16735906
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A safety-based comparison of pure LigaSure use and LigaSure-tie technique in total thyroidectomy.
    Pergel A; Yucel AF; Aydin I; Sahin DA; Aras S; Kulacoglu H
    Chirurgia (Bucur); 2014; 109(1):60-5. PubMed ID: 24524472
    [TBL] [Abstract][Full Text] [Related]  

  • 13. LigaSure versus conventional hemostasis in thyroid surgery: prospective randomized controlled trial.
    Singh P; O'Connell D; Langille M; Dziegielewski P; Allegretto M; Harris J
    J Otolaryngol Head Neck Surg; 2010 Aug; 39(4):378-84. PubMed ID: 20643002
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The use of the Ligasure for hemostasis during thyroid lobectomy.
    Musunuru S; Schaefer S; Chen H
    Am J Surg; 2008 Mar; 195(3):382-4; discussion 384-5. PubMed ID: 18207127
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Randomized controlled trial on vessel sealing in thyroid surgery].
    Minner S; Rödiger H; Mansmann U; Böhm B
    Zentralbl Chir; 2007 Oct; 132(5):446-50. PubMed ID: 17907089
    [TBL] [Abstract][Full Text] [Related]  

  • 16. LigaSure versus clamp-and-tie thyroidectomy for benign nodular disease.
    Petrakis IE; Kogerakis NE; Lasithiotakis KG; Vrachassotakis N; Chalkiadakis GE
    Head Neck; 2004 Oct; 26(10):903-9. PubMed ID: 15390199
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of the harmonic scalpel in thyroidectomy.
    Parker DJ; Krupa K; Esler R; Vujovic P; Bennett IC
    ANZ J Surg; 2009 Jun; 79(6):476-80. PubMed ID: 19566873
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Major complications in thyroid surgery: utility of bipolar vessel sealing (Ligasure Precise).
    Parmeggiani U; Avenia N; De Falco M; Parmeggiani D; Pisaniello D; d'Ajello M; Monacelli M; Calzolari F; Sanguinetti A; Sperlongano P
    G Chir; 2005 Oct; 26(10):387-94. PubMed ID: 16371192
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The use of Ligasure Vessel Sealing System in thyroid surgery.
    Lachanas VA; Prokopakis EP; Mpenakis AA; Karatzanis AD; Velegrakis GA
    Otolaryngol Head Neck Surg; 2005 Mar; 132(3):487-9. PubMed ID: 15746867
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prospective randomized trial of ligasure versus harmonic hemostasis technique in thyroidectomy.
    Rahbari R; Mathur A; Kitano M; Guerrero M; Shen WT; Duh QY; Clark OH; Kebebew E
    Ann Surg Oncol; 2011 Apr; 18(4):1023-7. PubMed ID: 21072688
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.