BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

251 related articles for article (PubMed ID: 19928082)

  • 1. A more accurate reconstruction system matrix for quantitative proton computed tomography.
    Penfold SN; Rosenfeld AB; Schulte RW; Schubert KE
    Med Phys; 2009 Oct; 36(10):4511-8. PubMed ID: 19928082
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of low-dose proton CT image registration for pretreatment alignment verification in reference to planning proton CT.
    Cassetta R; Piersimoni P; Riboldi M; Giacometti V; Bashkirov V; Baroni G; Ordonez C; Coutrakon G; Schulte R
    J Appl Clin Med Phys; 2019 Apr; 20(4):83-90. PubMed ID: 30933433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional portal image-based dose reconstruction in a virtual phantom for rapid evaluation of IMRT plans.
    Ansbacher W
    Med Phys; 2006 Sep; 33(9):3369-82. PubMed ID: 17022233
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning.
    Wu V; Podgorsak MB; Tran TA; Malhotra HK; Wang IZ
    Med Phys; 2011 Jul; 38(7):4451-63. PubMed ID: 21859046
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved proton computed tomography by dual modality image reconstruction.
    Hansen DC; Petersen JB; Bassler N; Sørensen TS
    Med Phys; 2014 Mar; 41(3):031904. PubMed ID: 24593722
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correction of CT artifacts and its influence on Monte Carlo dose calculations.
    Bazalova M; Beaulieu L; Palefsky S; Verhaegena F
    Med Phys; 2007 Jun; 34(6):2119-32. PubMed ID: 17654915
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ion range estimation by using dual energy computed tomography.
    Hünemohr N; Krauss B; Dinkel J; Gillmann C; Ackermann B; Jäkel O; Greilich S
    Z Med Phys; 2013 Dec; 23(4):300-13. PubMed ID: 23597413
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of beam purity and scanner complexity on proton CT accuracy.
    Piersimoni P; Ramos-Méndez J; Geoghegan T; Bashkirov VA; Schulte RW; Faddegon BA
    Med Phys; 2017 Jan; 44(1):284-298. PubMed ID: 28066887
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric impact of a CT metal artefact suppression algorithm for proton, electron and photon therapies.
    Wei J; Sandison GA; Hsi WC; Ringor M; Lu X
    Phys Med Biol; 2006 Oct; 51(20):5183-97. PubMed ID: 17019032
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Imaging dose management using multi-resolution in CT-guided radiation therapy.
    Sheng K; Jeraj R; Shaw R; Mackie TR; Paliwal BR
    Phys Med Biol; 2005 Mar; 50(6):1205-19. PubMed ID: 15798317
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Preliminary studies for a CBCT imaging protocol for offline organ motion analysis: registration software validation and CTDI measurements.
    Falco MD; Fontanarosa D; Miceli R; Carosi A; Santoni R; D'Andrea M
    Med Dosim; 2011; 36(1):91-101. PubMed ID: 20363613
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Chord-based image reconstruction in cone-beam CT with a curved detector.
    Zuo N; Xia D; Zou Y; Jiang T; Pan XC
    Med Phys; 2006 Oct; 33(10):3743-57. PubMed ID: 17089840
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Application of heavy-ion CT.
    Shinoda H; Kanai T; Kohno T
    Phys Med Biol; 2006 Aug; 51(16):4073-81. PubMed ID: 16885625
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Noise properties of chord-image reconstruction.
    Xia D; Yu L; Sidky EY; Zou Y; Zuo N; Pan X
    IEEE Trans Med Imaging; 2007 Oct; 26(10):1328-44. PubMed ID: 17948724
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simulation of x-ray-induced acoustic imaging for absolute dosimetry: Accuracy of image reconstruction methods.
    Forghani F; Mahl A; Patton TJ; Jones BL; Borden MA; Westerly DC; Altunbas C; Miften M; Thomas DH
    Med Phys; 2020 Mar; 47(3):1280-1290. PubMed ID: 31828781
    [TBL] [Abstract][Full Text] [Related]  

  • 16. IMRT verification by three-dimensional dose reconstruction from portal beam measurements.
    Partridge M; Ebert M; Hesse BM
    Med Phys; 2002 Aug; 29(8):1847-58. PubMed ID: 12201432
    [TBL] [Abstract][Full Text] [Related]  

  • 17. PET/CT imaging for treatment verification after proton therapy: a study with plastic phantoms and metallic implants.
    Parodi K; Paganetti H; Cascio E; Flanz JB; Bonab AA; Alpert NM; Lohmann K; Bortfeld T
    Med Phys; 2007 Feb; 34(2):419-35. PubMed ID: 17388158
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR).
    Chen B; Barnhart H; Richard S; Robins M; Colsher J; Samei E
    Med Phys; 2013 Nov; 40(11):111902. PubMed ID: 24320435
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantitative proton imaging from multiple physics processes: a proof of concept.
    Bopp C; Rescigno R; Rousseau M; Brasse D
    Phys Med Biol; 2015 Jul; 60(13):5325-41. PubMed ID: 26108277
    [TBL] [Abstract][Full Text] [Related]  

  • 20. On the use of a proton path probability map for proton computed tomography reconstruction.
    Wang D; Mackie TR; Tomé WA
    Med Phys; 2010 Aug; 37(8):4138-45. PubMed ID: 20879574
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.