1363 related articles for article (PubMed ID: 19928104)
21. MRI-controlled transurethral ultrasound therapy for localised prostate cancer.
Chopra R; Burtnyk M; N'djin WA; Bronskill M
Int J Hyperthermia; 2010; 26(8):804-21. PubMed ID: 21043572
[TBL] [Abstract][Full Text] [Related]
22. Transurethral ultrasound applicators with dynamic multi-sector control for prostate thermal therapy: in vivo evaluation under MR guidance.
Kinsey AM; Diederich CJ; Rieke V; Nau WH; Pauly KB; Bouley D; Sommer G
Med Phys; 2008 May; 35(5):2081-93. PubMed ID: 18561684
[TBL] [Abstract][Full Text] [Related]
23. Improved intercostal HIFU ablation using a phased array transducer based on Fermat's spiral and Voronoi tessellation: A numerical evaluation.
Ramaekers P; Ries M; Moonen CT; de Greef M
Med Phys; 2017 Mar; 44(3):1071-1088. PubMed ID: 28058731
[TBL] [Abstract][Full Text] [Related]
24. Hyperthermia by MR-guided focused ultrasound: accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction.
Salomir R; Vimeux FC; de Zwart JA; Grenier N; Moonen CT
Magn Reson Med; 2000 Mar; 43(3):342-7. PubMed ID: 10725875
[TBL] [Abstract][Full Text] [Related]
25. MR thermometry characterization of a hyperthermia ultrasound array designed using the k-space computational method.
Al-Bataineh OM; Collins CM; Park EJ; Lee H; Smith NB
Biomed Eng Online; 2006 Oct; 5():56. PubMed ID: 17064421
[TBL] [Abstract][Full Text] [Related]
26. Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators.
Chopra R; Burtnyk M; Haider MA; Bronskill MJ
Phys Med Biol; 2005 Nov; 50(21):4957-75. PubMed ID: 16237234
[TBL] [Abstract][Full Text] [Related]
27. Transrectal ultrasound applicator for prostate heating monitored using MRI thermometry.
Smith NB; Buchanan MT; Hynynen K
Int J Radiat Oncol Biol Phys; 1999 Jan; 43(1):217-25. PubMed ID: 9989529
[TBL] [Abstract][Full Text] [Related]
28. Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array.
Salgaonkar VA; Prakash P; Rieke V; Ozhinsky E; Plata J; Kurhanewicz J; Hsu IC; Diederich CJ
Med Phys; 2014 Mar; 41(3):033301. PubMed ID: 24593742
[TBL] [Abstract][Full Text] [Related]
29. Analysis of factors important for transurethral ultrasound prostate heating using MR temperature feedback.
Chopra R; Wachsmuth J; Burtnyk M; Haider MA; Bronskill MJ
Phys Med Biol; 2006 Feb; 51(4):827-44. PubMed ID: 16467581
[TBL] [Abstract][Full Text] [Related]
30. MRI-guided gas bubble enhanced ultrasound heating in in vivo rabbit thigh.
Sokka SD; King R; Hynynen K
Phys Med Biol; 2003 Jan; 48(2):223-41. PubMed ID: 12587906
[TBL] [Abstract][Full Text] [Related]
31. Ultrashort echo-time MRI versus CT for skull aberration correction in MR-guided transcranial focused ultrasound: In vitro comparison on human calvaria.
Miller GW; Eames M; Snell J; Aubry JF
Med Phys; 2015 May; 42(5):2223-33. PubMed ID: 25979016
[TBL] [Abstract][Full Text] [Related]
32. Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound.
de Senneville BD; Mougenot C; Moonen CT
Magn Reson Med; 2007 Feb; 57(2):319-30. PubMed ID: 17260361
[TBL] [Abstract][Full Text] [Related]
33. Explicit analytical tuning rules for digital PID controllers via the magnitude optimum criterion.
Papadopoulos KG; Yadav PK; Margaris NI
ISA Trans; 2017 Sep; 70():357-377. PubMed ID: 28688619
[TBL] [Abstract][Full Text] [Related]
34. Non-invasive determination of tissue thermal parameters from high intensity focused ultrasound treatment monitored by volumetric MRI thermometry.
Dragonu I; de Oliveira PL; Laurent C; Mougenot C; Grenier N; Moonen CT; Quesson B
NMR Biomed; 2009 Oct; 22(8):843-51. PubMed ID: 19562728
[TBL] [Abstract][Full Text] [Related]
35. A multi-element interstitial ultrasound applicator for the thermal therapy of brain tumors.
Canney MS; Chavrier F; Tsysar S; Chapelon JY; Lafon C; Carpentier A
J Acoust Soc Am; 2013 Aug; 134(2):1647-55. PubMed ID: 23927205
[TBL] [Abstract][Full Text] [Related]
36. Quantitative analysis of 3-D conformal MRI-guided transurethral ultrasound therapy of the prostate: theoretical simulations.
Burtnyk M; Chopra R; Bronskill MJ
Int J Hyperthermia; 2009 Mar; 25(2):116-31. PubMed ID: 19337912
[TBL] [Abstract][Full Text] [Related]
37. Online feedback focusing algorithm for hyperthermia cancer treatment.
Cheng KS; Stakhursky V; Stauffer P; Dewhirst M; Das SK
Int J Hyperthermia; 2007 Nov; 23(7):539-54. PubMed ID: 17943551
[TBL] [Abstract][Full Text] [Related]
38. Model predictive control for MR-HIFU-mediated, uniform hyperthermia.
Sebeke L; Deenen DA; Maljaars E; Heijman E; de Jager B; Heemels WPMH; GrĂ¼ll H
Int J Hyperthermia; 2019; 36(1):1040-1050. PubMed ID: 31621435
[No Abstract] [Full Text] [Related]
39. Mild hyperthermia by MR-guided focused ultrasound in an ex vivo model of osteolytic bone tumour: optimization of the spatio-temporal control of the delivered temperature.
Guillemin PC; Gui L; Lorton O; Zilli T; Crowe LA; Desgranges S; Montet X; Terraz S; Miralbell R; Salomir R; Boudabbous S
J Transl Med; 2019 Oct; 17(1):350. PubMed ID: 31651311
[TBL] [Abstract][Full Text] [Related]
40. Design and experiment of 256-element ultrasound phased array for noninvasive focused ultrasound surgery.
Lu M; Wan M; Xu F; Wang X; Chang X
Ultrasonics; 2006 Dec; 44 Suppl 1():e325-30. PubMed ID: 16949119
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]