451 related articles for article (PubMed ID: 19928110)
1. An iterative technique to segment PET lesions using a Monte Carlo based mathematical model.
Nehmeh SA; El-Zeftawy H; Greco C; Schwartz J; Erdi YE; Kirov A; Schmidtlein CR; Gyau AB; Larson SM; Humm JL
Med Phys; 2009 Oct; 36(10):4803-9. PubMed ID: 19928110
[TBL] [Abstract][Full Text] [Related]
2. Fully automated segmentation of oncological PET volumes using a combined multiscale and statistical model.
Montgomery DW; Amira A; Zaidi H
Med Phys; 2007 Feb; 34(2):722-36. PubMed ID: 17388190
[TBL] [Abstract][Full Text] [Related]
3. Threshold segmentation for PET target volume delineation in radiation treatment planning: the role of target-to-background ratio and target size.
Brambilla M; Matheoud R; Secco C; Loi G; Krengli M; Inglese E
Med Phys; 2008 Apr; 35(4):1207-13. PubMed ID: 18491512
[TBL] [Abstract][Full Text] [Related]
4. Validation of GATE Monte Carlo simulations of the GE Advance/Discovery LS PET scanners.
Schmidtlein CR; Kirov AS; Nehmeh SA; Erdi YE; Humm JL; Amols HI; Bidaut LM; Ganin A; Stearns CW; McDaniel DL; Hamacher KA
Med Phys; 2006 Jan; 33(1):198-208. PubMed ID: 16485426
[TBL] [Abstract][Full Text] [Related]
5. A novel fuzzy C-means algorithm for unsupervised heterogeneous tumor quantification in PET.
Belhassen S; Zaidi H
Med Phys; 2010 Mar; 37(3):1309-24. PubMed ID: 20384268
[TBL] [Abstract][Full Text] [Related]
6. Tumor delineation using PET in head and neck cancers: threshold contouring and lesion volumes.
Ford EC; Kinahan PE; Hanlon L; Alessio A; Rajendran J; Schwartz DL; Phillips M
Med Phys; 2006 Nov; 33(11):4280-8. PubMed ID: 17153406
[TBL] [Abstract][Full Text] [Related]
7. Iterative threshold segmentation for PET target volume delineation.
Drever L; Roa W; McEwan A; Robinson D
Med Phys; 2007 Apr; 34(4):1253-65. PubMed ID: 17500457
[TBL] [Abstract][Full Text] [Related]
8. Phantom validation of coregistration of PET and CT for image-guided radiotherapy.
Lavely WC; Scarfone C; Cevikalp H; Li R; Byrne DW; Cmelak AJ; Dawant B; Price RR; Hallahan DE; Fitzpatrick JM
Med Phys; 2004 May; 31(5):1083-92. PubMed ID: 15191296
[TBL] [Abstract][Full Text] [Related]
9. Effect of motion on tracer activity determination in CT attenuation corrected PET images: a lung phantom study.
Pevsner A; Nehmeh SA; Humm JL; Mageras GS; Erdi YE
Med Phys; 2005 Jul; 32(7):2358-62. PubMed ID: 16121593
[TBL] [Abstract][Full Text] [Related]
10. An innovative iterative thresholding algorithm for tumour segmentation and volumetric quantification on SPECT images: Monte Carlo-based methodology and validation.
Pacilio M; Basile C; Shcherbinin S; Caselli F; Ventroni G; Aragno D; Mango L; Santini E
Med Phys; 2011 Jun; 38(6):3050-61. PubMed ID: 21815378
[TBL] [Abstract][Full Text] [Related]
11. Influence of photon energy cuts on PET Monte Carlo simulation results.
Mitev K; Gerganov G; Kirov AS; Schmidtlein CR; Madzhunkov Y; Kawrakow I
Med Phys; 2012 Jul; 39(7):4175-86. PubMed ID: 22830751
[TBL] [Abstract][Full Text] [Related]
12. A region growing method for tumor volume segmentation on PET images for rectal and anal cancer patients.
Day E; Betler J; Parda D; Reitz B; Kirichenko A; Mohammadi S; Miften M
Med Phys; 2009 Oct; 36(10):4349-58. PubMed ID: 19928065
[TBL] [Abstract][Full Text] [Related]
13. A Dirichlet process mixture model for automatic (18)F-FDG PET image segmentation: Validation study on phantoms and on lung and esophageal lesions.
Giri MG; Cavedon C; Mazzarotto R; Ferdeghini M
Med Phys; 2016 May; 43(5):2491. PubMed ID: 27147360
[TBL] [Abstract][Full Text] [Related]
14. Segmentation of PET volumes by iterative image thresholding.
Jentzen W; Freudenberg L; Eising EG; Heinze M; Brandau W; Bockisch A
J Nucl Med; 2007 Jan; 48(1):108-14. PubMed ID: 17204706
[TBL] [Abstract][Full Text] [Related]
15. The development and testing of a digital PET phantom for the evaluation of tumor volume segmentation techniques.
Aristophanous M; Penney BC; Pelizzari CA
Med Phys; 2008 Jul; 35(7):3331-42. PubMed ID: 18697557
[TBL] [Abstract][Full Text] [Related]
16. Influence of different contributions of scatter and attenuation on the threshold values in contrast-based algorithms for volume segmentation.
Matheoud R; Della Monica P; Secco C; Loi G; Krengli M; Inglese E; Brambilla M
Phys Med; 2011 Jan; 27(1):44-51. PubMed ID: 20399128
[TBL] [Abstract][Full Text] [Related]
17. Development of a generic thresholding algorithm for the delineation of 18FDG-PET-positive tissue: application to the comparison of three thresholding models.
Vauclin S; Doyeux K; Hapdey S; Edet-Sanson A; Vera P; Gardin I
Phys Med Biol; 2009 Nov; 54(22):6901-16. PubMed ID: 19864698
[TBL] [Abstract][Full Text] [Related]
18. Monte Carlo simulation and scatter correction of the GE advance PET scanner with SimSET and Geant4.
Barret O; Carpenter TA; Clark JC; Ansorge RE; Fryer TD
Phys Med Biol; 2005 Oct; 50(20):4823-40. PubMed ID: 16204875
[TBL] [Abstract][Full Text] [Related]
19. Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATE.
Lamare F; Turzo A; Bizais Y; Le Rest CC; Visvikis D
Phys Med Biol; 2006 Feb; 51(4):943-62. PubMed ID: 16467589
[TBL] [Abstract][Full Text] [Related]
20. Fusion of PET and CT images using wavelet transform.
Shalchian B; Rajabi H; Soltanian-zadeh H
Hell J Nucl Med; 2009; 12(3):238-43. PubMed ID: 19936335
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]